On any given day myself and my Application Engineering Brethren here at EXAIR have discussions with customers on air starvation of any given EXAIR Product. The calls generally start off the same, “The Line Vac is not performing like it should”. We at EXAIR absolutely want to help you get the most out of our products and we certainly want them to perform to your expectation. However they must be supplied with clean/dry compressed air at sufficient pressure and volume.
Just the other day I was discussing a performance issue with a customer on a 1″ Line Vac. The customer thought he needed a larger Line Vac. I asked the questions regarding the diameter of his Supply Line and if he was using Quick Connect or Push Lock connectors. He was attempting to feed this Line Vac with 1/4″ Poly Tubing through a elbow Push to Loc fitting.
This 1″ Line Vac was being severely starved for air and therefore not performing as expected. The 1″ Line Vac require’s 14.7 SCFM @ 80PSI to reach the rated performance of 42″ of water column.
Below is a table for Pipe/Hose sizing from the Line Vac installation manual that you can use as a reference guide. It is recommended that if using hose for the supply air to go up to the next size over the pipe recommendation.
Don’t forget that quick connects and Push Lock fittings are not recommended and could restrict the air flow which will have a negative impact on performance.