Compressed Air Safety with EXAIR’s Intelligent Compressed Air Products

Compressed air is a necessary utility in any manufacturing environment. When used improperly, this compressed air can pose very real and serious dangers to your personnel. It’s imperative that you’re aware of the potential risks associated with the use of compressed air and educate yourselves and your operators to ensure you’re operating safely.

OSHA (Occupational Safety and Health Administration) provides standards designed to mitigate the risks of compressed air usage. If not adhered to, fines can be administered for each infraction. Fines are given out for each individual infraction. Meaning, if you have unsafe blowguns that are used in your facility you’ll get a notice for each individual gun that is identified during an inspection. Inspections aren’t something that happen often, but they will show up unannounced and often at the worst possible times.

OSHA Standard 1910.242(b) discusses the use of compressed air for cleaning and blowoff. It states that the use of compressed air for cleaning purposes is prohibited if the dead-ended pressure exceeds 30 psig. This phrase means the downstream pressure of the air nozzle or gun, used for cleaning purposes, will remain at a pressure level below 30 psig for all static conditions. In the event that dead ending occurs, the static pressure at the main orifice shall not exceed 30 psi. If it does exceed this pressure, there is a very high potential for it to create an air embolism. An air embolism, left untreated, can quickly impede the flow of blood throughout the body. This can lead to stroke, heart attack, and sometimes death.

With this in mind, there are only two options for staying within compliance of this standard. Either install an engineered solution that will reduce the air pressure to less than 30 psig if dead-ended, or regulate the pressure below 30 psig. For the vast majority of operations, regulating the input pressure below 30 psig is useless. The force and flow from the nozzle at this pressure is greatly reduced and likely not enough to be effective in most applications. All of EXAIR’s Safety Air Guns are designed so that the flow cannot be dead-ended. The fins on the Super Air Nozzles are not only useful in amplifying the force by drawing in ambient air, but they also prevent an operator from completely obstructing the airflow.

In addition to being concerned about dead-end pressure, OSHA 1910.242(b) also states that compressed air used for cleaning should include effective chip guarding. By this, they mean that some method or equipment must be installed that will prevent chips and particles from coming back into the eyes or skin of the operator. In addition to offering OSHA compliant nozzles and guns, EXAIR also has Chip Shields that can be installed onto any of our Safety Air Guns. The polycarbonate shields protect the operator from any flying debris while performing a drying or blowoff operation. Simply add a “-CS” to the end of any Safety Air Gun Model number to have a Chip Shield installed on the gun.

Hearing loss due to high noise levels is another common problem in many industrial facilities. Without the use of proper PPE, hearing loss can occur quickly. This is a serious concern as hearing loss is permanent and once the damage is done there’s no way to reverse it. Due to this risk, OSHA strictly enforces standard 29 CFR-1910.95(a).

Hearing loss is the best known, but not the only, ill effect of harmful noise exposure. It can also cause physical and psychological stress, impair concentration, and contribute to workplace accidents or injuries.

This directive discusses the effects of noise and limits exposure based on the dBA. The table below indicates the maximum allowable exposure time to different noise levels. Sound levels that exceed these levels should first be addressed by proper engineering controls such as isolating the source of the sound from personnel or replacing the cause of the sound with something like an engineered compressed air nozzle. When such controls aren’t feasible, proper PPE must be worn to protect the operator.

The Occupational Safety and Health Act of 1970 does not contain any provisions that allow for the approval or endorsement of equipment. Alteration or the misapplication of what was once a safe piece of equipment would create a dangerous scenario that is out of the control of the original manufacturer. Any nozzles or guns marketed as “OSHA approved” should immediately throw up a red flag. Identifying and implementing a safe, OSHA compliant solution rests in the hands of the manufacturer themselves. If you’ve got questions about compressed air safety or have an existing blowoff in place that does not adhere to this OSHA directive, give us a call. We’ll be sure to recommend a solution that will keep your operators and wallets safe!