Solving Static and Increasing Print Quality on Food Packaging

Gen4 Static Eliminators

A yogurt company printed bar codes on every cup that they produced. This was necessary for registering and tracing their product. After failing a bar code reader quality test, they started noticing some print issues during batch runs. They would have to stop their system, clean the inkjet printer head, and scrap product that would not register with the bar code reader.

This affects production rates, scrap rates, and overall cost. They stated that they threw away 30 to 40 cases per batch of yogurt due to this problem. They had an EXAIR catalog where they found a similar application within our Gen4 Static Eliminator product line. They contacted us to see if we could find a solution.

With non-conductive material like plastic, static is easily generated; especially during cooler weather. Static can be in a negative state or a positive state dependent on the material. For opposite charges, things are attracted to each other and will “stick” like magnets. For similar charges, they will repel each other. The higher the static charge, the stronger the force.

For the company above, the yogurt cups moved along a 7” (178mm) wide conveyor before they reached the bar code printer. This movement causes static to be generated on the surface of the cups. But, what about the inkjet printer? The function of the printer charges the ink droplets for direction and positioning. Since the ink droplets and the cup surfaces have the same charge, the droplets were being “pushed” back toward the printing head (reference photo below). Thus, the ink would dry on the surface and affect the quality of the bar code.

Bar Code Printer

When it comes to removing static, EXAIR is a leader in this market. We have a large product line of different types of Static Eliminators. Our design generates both positive and negative ions to remove any type of static charge. Since we only had to remove the static from the surface of the cup, I recommended a Gen4 Ionizing Bar. With a quick static decay rate, we can remove the static right before the bar code printer with only one Gen4 Ionizing Bar. For this application, I recommended the model 8003 3” Gen4 Ionizing Bar and a model 7960 Gen4 Power Supply. Together, it was very easy to mount and start using. EXAIR stocks lengths from 3” (76mm) up to 108” (2743mm), and we can ship a solution the same day. When you are losing 30 to 40 cases, time matters. And for this company, they received the items the next day to correct the misprints and short printing runs.

Gen4 Ionizing Bar w/ power supply

When problems occur, time can be of the essence. This is why EXAIR stocks our cataloged items for fast delivery.  For the company above, they had an EXAIR catalog which helped them to find a solution. If you would like to have an EXAIR catalog, you can click here to get one.   After they started using the Ionization Bar, the static was removed, the bar code was clean, and the operation ran smoothly. If static is causing issues for you, you can contact EXAIR and speak to one of our Application Engineers. We will be happy to assist you.

John Ball
Application Engineer

Email: johnball@exair.com
Twitter: @EXAIR_jb

Leave a Reply