Installing a Secondary Receiver Tank

Picture by Clker-Free-Vector licensed by Pixabay

We often run into situations where a customer does not have enough compressed air volume to implement a solution. This leaves three possible options. 1) Abandon the project all together and continue to feel the pain the problem creates. 2) Install a larger compressor, with associated expense. 3) Install a secondary, or “point of use” receiver tank to store the compressed air volume local to the application, to be available immediately without having to rely on the distribution system for storage capability. This 3rd option is a cost-effective solution customers often use to mitigate the impact of installing a new compressed air consuming product onto the system.

Large demand events on a compressed air system can leave the system short on air. This can result in a system pressure drop which is undesirable. Utilizing a secondary receiver tank to mitigate the impact of larger volume consuming events is a common and useful strategy that many compressed air professionals will recommend and pursue. In this kind of scenario, the receiver tank acts much like a capacitor in a camera flash. A camera battery charges a capacitor which then dumps its charge into the flash bulb when you take a photo for a notably bright flash which is what one generally wants from their camera flash.

In this same way, a receiver tank acts like the capacitor to “dump” the air volume needed to make a compressed air device work at its design pressure and flow for some prescribed period of time. In situations like this, the high demand does need to be an intermittent one so that the tank can then re-charge from the compressor system and be ready for the next air use event. This means that certain calculations need to be made to ensure that the receiver tank is sized properly to provide the desired effect.

How do you size a receiver tank? Here’s the calculation to determine the proper size:

Let’s consider an example of an Air Amplifier solution. A customer wants to blow on hot metal parts coming out of an oven to cool them down as an “air quench”. We evaluate the application and determine that (2) 2″ Super Air Amplifiers will provide the right amount of flow. Those units are going to operate at 60 PSIG to provide the desired effect. (2) 2″ Super Air Amplifiers will consume 24.5 SCFM @ 60 PSIG. Each batch of parts comes out of the oven at a rate of one batch every 5 minutes. They want to provide the necessary cooling for a total of 30 seconds to have the air quench effect. So, every 5 minutes, the Air Amplifiers will be blowing for 1/2 minute. Each “on” event consumes 12.25 Standard Cubic Feet of air. We then have 4 minutes, 30 seconds left to re-plenish the tank.

The last piece of information we need to know is the system pressure for the compressed air header feeding the tank. The system pressure is 120 PSIG. And so, our calculation looks like this:

V = 0.5 min. x 24.5 rate of flow x (60 PSIG + 14.5 PSIA)
120-60

V = 913
60

V = 15.2 ft.3

There are 7.48 gallons to a cubic foot, so our receiver tank in this example would be
15.2 ft.3 x 7.48 = 114 gallons.

Given the fact that receiver tanks are made in certain, standard sizes, a 120 gallon tank or two, 60 gallon tanks piped in upstream of the compressed air load would be appropriate for this application.

As a further note to the example, the refill rate to the tank(s) would need to be a minimum of 2.72 SCFM to get the volume replenished in time for the next event. This is less than 1 HP of industrial air compressor to maintain such a flow rate to refill the tank.

With some reasonably simple math to determine tank size, and a willingness to pursue this kind of air delivery solution, you can implement that compressed air solution at a fraction of the cost compared to a new compressor.

EXAIR LLC
Visit us on the Web

Cover Photo by dkeissling and licensed by Pixabay

Wet Receivers and Condensate Drains

Receiver Tank

For properly designed compressed air systems, air compressors will use primary storage tanks, or receivers.  They are necessary to accommodate for fluctuations in airflow demand and to help prevent rapid cycling of the air compressor.  (Reference: Advanced Management of Compressed Air – Storage and Capacitance)  There are two types of primary receivers, a wet receiver tank and a dry receiver tank.  The wet receiver is located between the air compressor and the compressed air dryer where humid air and water will be stored.  The dry receiver is located after the compressed air dryer.  In this blog, I will be reviewing the wet receivers and their requirements as a storage tank.

Air compressors discharge hot humid air created by the internal compression.  A byproduct of this compression is water.  By placing a wet receiver on the discharge side of the air compressor, this will create a low velocity area to allow the excess water to fall out.  It will also give the hot air time to cool, allowing the compressed air dryers to be more effective.  With wet receivers, it will reduce cycle rates of your air compressors for less wear and store compressed air to accommodate for flow fluctuations in your pneumatic system.

But, there are some disadvantages with a wet receiver.  For compressed air dryers, it is possible to exceed the specified flow ratings.   If the demand side draws a large volume of air from the supply side, the efficiency of the compressed air dryers will be sacrificed, allowing moisture to go downstream.  Another issue with the wet receiver is the amount of water that the air compressor is pumping into it. As an example, a 60 HP air compressor can produce as much as 17 gallons of water per day.  As you can see, it would not take long to fill a wet receiver.  So, a condensate drain is required to get rid of the excess water.

Condensate drains come in different types and styles.  They are connected to a port at the bottom of the wet receiver where the water will collect.  I will cover the most common condensate drains and explain the pros and cons of each one.

  • Manual Drain – A ball valve or twist drain are the least efficient and the least expensive of all the condensate drains. The idea of having personnel draining the receiver tanks periodically is not the most reliable.  In some cases, people will “crack” the valve open to continuously drain the tank.  This is very inefficient and costly as compressed air is being wasted.
  • Timer Drain Valves – These valves have an electric timer on a solenoid to open and close a two-way valve or a ball valve. The issue comes in trying to set the correct time for the open and close intervals.  During seasonal changes, the amount of water going into the wet receiver will change.  If the timer is not set frequent enough, water can build up inside the receiver.  If too frequent, then compressed air is wasted.  Compared to the manual valve, they are more reliable and efficient; but there is still potential for compressed air waste.

    Timer Relay
  • No-waste Drains – Just like the name, these drains are the most efficient. They are designed with a float inside to open and close a drain vent.  What is unique about the float mechanism is that the drain vent is always under water.  So, when the no-waste drain is operating, no compressed air is being lost or wasted; only water is being drained.  The most common problem comes with rust, sludge, and debris that can plug the drain vent.

All wet receivers require a condensate drain to remove liquid water.  But, the importance for removing water without wasting compressed air is significant for saving money and compressed air.  EXAIR also has a line of Intelligent Compressed Air® products that can reduce your compressed air waste and save you money.  You can contact an Application Engineer for more details.

John Ball
Application Engineer