Basics of the Compressor Room

EXAIR Corporation has staked our reputation on a keen ability to help you get the most out of your compressed air system since 1983.  Now, the bulk of our expertise lies in the implementation and proper use of engineered products on the demand side, but we fully recognize that there are critical elements for optimization on the supply side too.  And that, quite literally, starts in the compressor room.  This is not an exhaustive, specifically detailed list, but here are some you might consider to get the most from the (again, quite literally) beginning:

  • Location.  If you’re building a new facility, or doing a major rehab of your existing one, having the compressor room as close as practical to the point(s) of use is best, IF all other things are equal.  You’ll use less pipe if you don’t have to run it so far.  You’ll also be able to use smaller diameter lines because you won’t have to worry about line loss (pressure drop due to friction as the air flows through the total length) as much.
  • Location part 2.  If all other things are NOT equal, having the compressor room close to the point of use may not be best for you.
    • Your air compressor pulls in air from the immediate environment.  It’s better to go with longer and bigger pipe in your distribution system than it is to put your compressor in a location where it’ll pull in dust & particulate from grinding operations, humidity from a boiler plant, fumes from chemical production, etc.
    • There are some pretty darn quiet air compressors out there, but there are some pretty loud ones too.  Especially in small to mid size facilities, putting the compressor in an area that upsizes the required piping is still likely a better idea, due to the downsizing of the noise levels that personnel will be exposed to.
  • Environment.  No matter where your compressor is located, the machine itself should be protected from heat and other harsh environmental elements.  That means if it’s inside the plant, the compressor room should be adequately ventilated.  In some situations, the compressor may be best installed outside the plant, in its own building or protective structure.  This should be designed to protect against solar load…in addition to the high temperature associated with a hot summer day, the sun’s rays beating down on your air compressor will radiate a tremendous amount of heat into it.
  • Filtration.  Whatever is in the air in your compressor room is going to get into your compressed air.  This is doubly problematic: particulate debris can damage the air compressor’s moving parts, and it can likewise damage your pneumatic cylinders, actuators, tools, motors, etc. as well.  Make sure the intake of your compressor is adequately filtered.
  • Maintenance.  Air compressors, like any machinery with moving parts, require periodic preventive maintenance, and corrective maintenance when something inevitably breaks down.  There should be adequate space factored in to your compressor room’s layout for this.  The only thing worse than having to fix something is not having the room to fix it without taking other stuff apart.
Patrick Duff, a production equipment mechanic with the 76th Maintenance Group, takes meter readings of the oil pressure and temperature, cooling water temperature and the output temperature on one of two 1,750 horsepower compressors. Each compressor is capable of producing 4,500 cubic feet of air at 300 psi. The shop also has a 3,000 horsepower compressor that produces 9,000 cubic feet of air at 300 psi. By matching output to the load required, the shop is able to shut down compressors as needed, resulting in energy savings to the base. (Air Force photo by Ron Mullan)

These are a few things to consider on the supply end.  If you’d like to talk about how to get the most out of your compressed air system, EXAIR is keen on that.  Give us a call.

Russ Bowman
Application Engineer
EXAIR Corporation