The Adjustable Spot Cooler – Cold Air to -30°F (-34°C) From Your Compressed Air Supply

The Adjustable Spot Cooler is a low cost, reliable , maintenance free way to provide spot cooling to a myriad of industrial applications. Simply turn the knob, and the temperature can be changed to suit the needs of the process. The Adjustable Spot Cooler delivers precise temperature settings from -30°F (-34°C) to room temperature.

Adjustable Spot Cooler
Adjustable Spot Cooler

The Adjustable Spot Cooler utilizes the Vortex Tube technology that converts compressed air into a cold air stream. To learn more about EXAIR vortex tubes, click here.

  • It can produce temperatures form -30°F to +70°F (-34°C tp +21°C)
  • Parts included for flow rates of 15, 25 and 30 SCFM (425, 708, 850 SLPM.) The unit comes from the factory set at 25 SCFM (708 SLPM)
  • It can produce refrigeration up to 2,000 BTU/hr (504 Kcal/hr.)

A swivel magnetic base allows for easy mounting and portability, you can move it from machine to machine as needed. The flexible cold air outlet tubing holds its position and is easy to aim. Most importantly, there are no moving parts or CFC’s, ensuring maintenance free operation.

asc_onlathecmyk
The Adjustable Spot Cooler maintains critical tolerances on machined plastic parts

How the Adjustable Spot Cooler WorksThe Adjustable Spot Cooler incorporates a vortex tube to convert a supply of compressed air (1) into two low pressure streams, one hot and one cold. With the turn of a knob, the temperature control valve (2) allows some hot air to flow through a muffling sleeve and out the hot air exhaust (3). The opposite end provides a cold air stream (4) that is muffled and discharged through the flexible hose, which directs it to the point of use. The swivel magnetic base (5) provides easy mounting and portability.


The Adjustable Spot Cooler can produce a wide range of air flows and temperatures as determined by the temperature control valve knob setting and the generator installed. The generator controls the total SCFM (SLPM) of compressed air consumption, and is easy to change. From the factory, the 25 SCFM (708 SLPM) generator is installed, producing up to 1,700 BTU/hr (429 Kcal/hr) of cooling. For less cooling, the 15 SCFM (425 SLPM) generator can be installed, providing up to 1,000 BTU/hr (252 Kcal/hr) of cooling. And for more cooling, the 30 SCFM (850 SLPM) generator can be installed, providing up to 2,000 BTU/hr (504 Kcal/hr) of cooling.

Adjustable Spot Cooler Specifications

Two (2) Systems are available as shown below, and include the 15 and 30 SCFM (425 and 850 SLPM) generators, a filter separator, and either a single or dual point hose kit.

Adjustable Spot Cooler Systems3825_3925 adj spot cooler

If you have questions about the Adjustable Spot Cooler or any of the 16 different EXAIR Intelligent Compressed Air® Product lines, feel free to contact EXAIR and myself or any of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

The Theory of the Vortex Tube

There are many theories regarding the dynamics of a vortex tube and how it works. Many a graduate student has studied them as part of their research requirements.

VT_air2

The Vortex Tube was invented by accident in 1928, by George Ranque, a French physics student. He was performing experiments on on a vortex-type pump that he had developed and noticed that warm air exhausted from one end and cold air from the other! Ranque quickly stopped work on the pump, and started a company to take advantage of the commercial possibilities for this odd little device that produced both hot and cold air, using only compressed air, with no moving parts. The company was not successful, and the vortex tube was forgotten until 1945 when Rudolph Hilsch, a German physicist, published a widely read paper on the device.

A vortex tube uses compressed air as a power source, has no moving parts, and produces hot air from one end and cold air from the other. The volume and temperature of the two air streams is adjustable with a valve built into the hot air exhaust.  Temperatures as low as -50°F (-46°C) and as high as 260°F (127°C) are possible.

Here is one widely accepted explanation of the physics and the phenomenon of the vortex tube.VT

Compressed air is supplied to vortex tube and passes through nozzles that are tangent to to an internal counterbore (1). As the air passes through it is set into a spiraling vortex motion (2) at up to 1,000,000 rpm. The spinning stream of air flows down the hot tube in the form of a spinning shell, like a tornado (in red). The control valve (4) at the end allows some of the warmed air to escape (6) and what does not escape reverses direction and heads back down the tube as a second vortex (in blue) inside of the low pressure area of the larger warm air vortex. The inner vortex loses heat and exits the through the other end of as cold air (5).

It is thought that that both the hot and cold air streams rotate in the same direction at the same angular velocity, even though they are travelling in opposite directions. A particle of air in the inner stream completes one rotation in the same amount of time that an air particle in the outer stream. The principle of conservation of angular momentum would say that the rotational speed of the inner inner vortex should increase because the angular momentum of a rotating particle (L) is equal to the radius of rotation (r) times its mass (m) times its velocity (v).  L = r•m•v.  When an air particle moves from the outer stream to the inner stream, both its radius (r) and velocity (v) decrease, resulting in a lower angular momentum. To maintain an energy balance for the system, the energy that is lost from the inner stream is taken in by the outer stream as heat. Therefore, the outer vortex becomes warm and the inner vortex is cooled.

At EXAIR, we have harnessed the cooling power of the vortex tube, and it can be found and utilized in such products as Spot Coolers, Cabinet Coolers, and the Vortex Tube themselves.

Harnessing the cooling power of the vortex tube 

If you have questions about Vortex Tubes, or would like to talk about any of the EXAIR Intelligent Compressed Air® Products, feel free to contact EXAIR and myself or any of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

 

Controlling Temperature and Flow in a Vortex Tube

VT_air2

A few weeks ago, we looked at the Vortex Tube and provided a general overview of the device (see that blog here.)  In a nutshell – a Vortex Tube uses an ordinary supply of compressed air as a power source, creating two streams of air, one hot and one cold – resulting in a low cost, reliable, maintenance free source of cold air for spot cooling solutions.

One of the features of the Vortex Tube is that the temperature of the cold air and the cold air flow rate is changeable. The cold air flow and temperature are easily controlled by adjusting the slotted valve in the hot air outlet.

Vortex Tube Hot Valve Adjustment
Hot Valve Adjustment for a Vortex Tube

Opening the valve (turning it counterclockwise) reduces the cold air flow rate and the lowers the cold air temperature.  Closing the valve (turning it clockwise) increases the cold air flow and raises the cold air temperature.

VT Adjustment Table

As with anything, there is a trade off – to get higher a cold air flow rate, a moderate cold air temperature is achieved, and to get a very cold air temperature, a moderate air flow rate is achieved.

An important term to know and understand is Cold Fraction, which is the percentage of the compressed air used by the Vortex Tube that is discharged through the Cold End.  In most applications, a Cold Fraction of 80% produces a combination of cold flow rate and and cold air temperature that results in the maximum refrigeration or cooling output form a Vortex Tube.

For most industrial applications – such as process cooling, part cooling, and chamber cooling, maximum refrigeration is best and the 32XX series of Vortex Tubes are preferred.  For those applications where ‘cryogenic’ cooling is needed, such as cooling lab samples, or circuit testing, the 34XX series of Vortex Tube is best.

To set a Vortex Tube to a specific temperature, simply insert a thermometer into the cold air exhaust and adjust the hot valve.  Maximum refrigeration, at 80% Cold Fraction, is achieved when the cold air temperature drop is 50°F (28°C) from the incoming compressed air temperature. See the video posted here for measuring and lowering and the cold air temperature.

For those cases when you may be unsure of the required cold air flow rate and cold air temperature to provide the needed cooling in an application, we would recommend an EXAIR Cooling Kit.  The Cooling Kit contains a Vortex Tube, Cold Air Muffler, Air Line Filter, and a set of Generators that will allow for experimentation of the full range of air flows and temperatures possible.

gh_VTcoolingkit_750x696p
EXAIR Vortex Tube Cooling Kit

To discuss your application and how a Vortex Tube or any EXAIR Intelligent Compressed Air Product can improve your process, feel free to contact EXAIR, myself, or one of our other Application Engineers. We can help you determine the best solution!

Brian Bergmann
Application Engineer

Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

Vortex Tube Overview

VT_air2

A Vortex Tube uses an ordinary supply of compressed air as a power source, creating two streams of air, one hot and one cold – resulting in a low cost, reliable, maintenance free source of cold air for spot cooling solutions.

The EXAIR Vortex tubes are made of stainless steel, which provides resistance to wear, corrosion and oxidation – ensuring years of reliable, maintenance free operation

How_A_Vortex_Tube_Works

The cold air flow and temperature are easily controlled by adjusting the slotted valve in the hot air outlet.  Opening the valve reduces the cold air flow and the cold air temperature.  Closing the valve increases the cold air flow and and the cold air temperature.

EXAIR Vortex Tubes come in three sizes. Within each size, a number of flow rates, which are dictated by a small internal generator, are available. Selection of the appropriate Vortex Tube can be achieved either by knowing the BTU/hr (Kcal/hr) requirements or the desired flow and temperature requirements. Selection is then based on the specification table (BTU/hr or Kcal/hr is known) or the performance tables (flow and temperature is known.)

Capture
Vortex Tube Specification Tables

 

Cold Fraction
Vortex Tube Performance Tables

The performance of a Vortex Tube is reduced with back pressure on the cold air exhaust. Low back pressures up to 2 PSIG ( 0.1 Bar) will not change performance and a 5 PSIG (0.3 Bar) will change the temperature drop by approximately 5°F (2.8°C)

The use of clean air is essential, and filtration of 25 microns or less is recommended.  EXAIR offers filters with 5 micron elements and properly sized for flow.

A Vortex Tube provides a temperature drop to the incoming supply air.  High inlet temperatures will result in a corresponding rise in the cold air temperature.

EXAIR offers mufflers for both the hot and cold air discharge.  If the cold air is ducted, muffling may not be required.

For best performance, operation at 80 to 110 PSIG (5.5 to 7.6 Bar) of supply pressure is recommended. The Vortex Tubes have a maximum pressure rating of 250 PSIG (17.2 Bar) and a minimum requirement of 20 PSIG (1.4 Bar)

To discuss your application and how a Vortex Tube or any EXAIR Intelligent Compressed Air Product can improve your process, feel free to contact EXAIR, myself, or one of our other Application Engineers. We can help you determine the best solution!