Reducing the Noise with EXAIR Mufflers

Hearing loss is the best known, but not the only, ill effect of harmful noise exposure. It can also cause physical and psychological stress, impair concentration, and contribute to workplace accidents or injuries.

Many manufacturing plants have a strong focus on safety for their workers.  One major safety concern that is overlooked is noise.   The Occupational Safety and Health Administration has a directive, 29 CFR 1910.95a, that defines noise exposure levels over time.  For an eight-hour day, the maximum noise level is 90 dBA.  Hearing loss is irreversible, but it can be prevented.  The CDC, Center for Disease Control, and NIOSH, National Institute for Occupational Safety and Health, report that “approximately 18% of all manufacturing workers have hearing difficulty”1

EXAIR manufactures intelligent compressed air® products to reduce noise levels in the work environment with our Super Air Nozzles, Super Air Knives, and Safety Air Guns for blow-off applications.  But there is another culprit that can be heard; discharge exhaust.  In this blog, I will cover the different types of mufflers that we offer to help reduce these sound levels.

Reclassifying Mufflers are designed to have two functions. They can cut noise levels by 35 dB and remove oil mist from the exhaust air.  Cylinders and valves that exhaust pressurized air may have oil in the line to keep the seals from sticking.  When exhausted, it can create a fine mist, which is dangerous for operators.  Reclassifying mufflers can reduce loud noise while also collecting any contaminants in the exhaust air.

Sintered Bronze Mufflers are simple in design, cost-effective, and easy to install. They have minimal back pressure to not restrict the operations of the pneumatic device.  They come in sizes from #10-32 thread to 1-1/2” NPT.  For a quick and simple way to reduce noise, the Sintered Bronze Mufflers are in stock for fast delivery.

Straight-Through Mufflers offer a way to reduce noise levels without worrying about clogging. They have an aluminum shell lined with sound-absorbing foam, and they can reduce the noise level by 20 dB.  EXAIR offers them with ports of ¼” NPT, 3/8” NPT, and ¾” NPT.  One side has a female thread, while the opposite side will have a male thread.  This can allow you to connect other items like hose kits to reduce noise.

In harsh environments, Heavy Duty Mufflers are used.  They have an outer aluminum shell with an internal stainless-steel screen.  They protect components like valves and cylinders from contamination entering the part.  And, the Heavy Duty Muffler can keep contaminants like rust from being ejected at high speed into the work area. They have a typical noise reduction of 14 dB.

Here is a test for you.  If you go and stand in your plant, you can probably hear loud noises coming from your pneumatic system.  EXAIR has engineered products to solve most of them.  In the Hierarchy of Controls from NIOSH, Personal Protection Equipment, or PPE, is the least effective.  A better control from this chart would be to isolate your operators from the hazard with an engineered product.  EXAIR can offer these solutions for many of your blow-off and pneumatic discharge applications.  If you wish to discuss in further details about the safety improvements that EXAIR can provide, you can contact an Application Engineer.  We will be happy to help. 

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

Note 1: https://www.cdc.gov/niosh/topics/ohl/manufacturing.html

EXAIR Product Overview: Mufflers

Noise, we all hate it to some extent. From the hustle and bustle of crowed streets to the whine of a jet engine noise has plagued the world for eons leaving people to search for a way to escape into a moment of peace and quiet. The majority of people that I know pack their massive over sized backpacks and head deep into the mountains for days on end to escape the noise sometimes traveling for 10+ miles at a time. But how can we help eliminate this monstrosity that we have created in our manufacturing environments? The answer is mufflers, and no I don’t mean your car muffler (although they do the same thing) I mean compressed air mufflers. Compressed air can be a loud utility inside of a plant environment and exceed the OSHA guidelines for personnel noise exposure. But this noise can easily be mitigated with the use of Intelligent compressed air products and mufflers.

Big Sandy Lake Trail – Wind River Range State Park, WY

OSHA Standard 29 CFR 1910.95(a) outlines the total noise exposure to a particular noise level per day and dictates that noise exposure at or above 85 decibels require ear protection. By placing a muffler on the end of the pipe one can reduce the sound level significantly to the point it could be the difference between having to wear ear protection and not having to. With that being said EXAIR offers four different types of mufflers to choose from and they are Reclassifying, Sintered Bronze, Straight-Through, and Heavy Duty.

Reclassifying mufflers offer the best noise reduction at 35 dB and have the added benefit of removing oil mist from the air line. This means that the Reclassifying mufflers are ideal for pneumatic cylinders. Per OSHA Standard 29 CFR 1910.1000 worker shall not be exposed to more than 5mg/m3 of oil by volume in a 40-hour work week. The patented design of the removable element separates oil from the exhausted air and meets or exceeds the OSHA Standard.

Sintered Bronze Mufflers are an excellent low-cost solution which can be easily installed into your current existing ports. These mufflers also come in the largest variety of different sizes ranging from thread sizes of #10-32 to 1.5” NPT. Also, the Sintered Bronze Mufflers are specifically designed to provide the minimal amount of back pressure and restriction. The main difference between these mufflers and the reclassifying is that the Sintered Bronze Mufflers cannot collect oil out of the exhaust.

The quick pick chart for easily choosing which muffler you need

If the process air needs to be directly plumbed away from personnel, then the Straight-Through Muffler is the way to go. Straight-Through Mufflers are ideal for situations that require both a threaded inlet and exhaust. In most applications you will see the Straight-Through Muffler pair with our E-Vac vacuum generators or Vortex Tubes to provide noise reduction of the unit. All in all, the Straight-Through Muffler can reduce noise levels up to 20 dB.

Model 3913 Straight-Through Muffler

Lastly, the Heavy Duty Muffler provides a corrosion resistant aluminum outer shell with a stainless steel inner screen. This design allows the muffler to catch any contaminants such as rust from being ejected potentially causing harm or quality defects. Typically, this muffle will reduce noise levels up to 14 dB.

Model 3903 Heavy Duty Muffler

If you have any questions or want more information on EXAIR’s E-Vacs and their Accessories. Give us a call, we have a team of application engineers ready to answer your questions and recommend a solution for your applications.

Cody Biehle
Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook

Compressed Air Accessories for Clean Air, Quiet Air, and Adjustability

In this blog, I would like to turn your attention to our accessories that support our Intelligent Compressed Air® Products.  EXAIR products use compressed air to coat, conserve, cool, convey and clean.  To maximize the performance, it is important to have the controls and options to increase their “flexibility”.  EXAIR offers these items as Accessories.  Pneumatic applications come in many variations and forms, and Accessories can help you to adapt to your application and to remove any “guess work”.

Here are the different categories and explanations of each item that EXAIR recommends for our products.  With their defined functions, they can help you in different areas to enhance your pneumatic experience.

Filters/Regulators:

  • Filter Separators remove bulk liquid and contamination from the compressed air stream. EXAIR stocks a range of sizes from ¼” NPT ports to 1 ¼” NPT ports.  They use a 5-micron filter and a mechanical baffle to remove slugs of liquid from your compressed air system.  Most Filter Separators have an auto-drain to automatically remove the buildup of liquid inside the bowl.   I would consider the Filter Separator as a minimum level of protection required to protect your EXAIR products.
  • The Oil Removal Filters remove very small particles of dirt and oil from the compressed air; making it even cleaner. The 0.03-micron media of the Oil Removal Filter will “coalesce” the fine liquid particles into large droplets.  Thus, allowing gravity to remove it from the compressed air stream.  EXAIR offers different sizes ranging from ¼” NPT to 1 ½” NPT ports.  As a note, Oil Removal Filters are great for removing very fine particles, but if you have a system with lots of water, I would recommend a Filter Separator upstream of the Oil Removal Filter for optimal filtration.
  • Pressure Regulators control the amount of air pressure being supplied to your EXAIR products. This is important if you are trying to save compressed air, control the force, or convey material.  EXAIR, being a leader in compressed air savings, recommends to use the minimum amount of air pressure to do the job.  This will save compressed air and save you money.  Regulators have a characteristic called “droop”.  Droop is the amount of air pressure that it drops downstream when you start flowing compressed air.  If the regulator is not sized properly, you can “starve” your pneumatic component, causing loss of function.  EXAIR properly sizes our regulators in our kits to make sure that you won’t “starve” our product.
  • EXAIR also offers Mounting Brackets for the regulators and the filters to help support them to a wall or structure. To connect filters and regulators together without a pipe nipple, we also have Coupling Kits for sizes up to ¾” NPT.  And for combination kits which includes a filter and a regulator, we offer the Mounting Bracket and Coupling Kit together for a set.

Silencing Mufflers:

  • Reclassifying Mufflers are designed to have two functions. They can reduce noise levels by 35 dB and remove oil mist from the exhaust air.  Cylinders and valves that exhaust pressurized air may have oil in the line to keep the seals from sticking.  When exhausted, it can create a fine mist which is dangerous for operators.  The Reclassifying Mufflers can reduce the loud noise as well as collect any contamination from the exhaust air.
  • Sintered Bronze Mufflers are simple in design, cost effective, and easy to install. They have a minimal back pressure to not restrict operations of the pneumatic device.  They come in sizes from #10-32 thread to 1-1/2 NPT.  For a quick and simple way to reduce noise, the Sintered Bronze Mufflers are in stock for fast delivery.
  • Straight-Through Mufflers offer a way to reduce noise levels without worrying about clogging. They have an aluminum shell lined with sound absorbing foam, and they can reduce the noise level by 20 dB.  EXAIR offers them with two ports from ¼” NPT to ¾” NPT.  This can allow you to connect other items like blowing hose kits while reducing noise.
  • Heavy Duty Mufflers have an outer aluminum shell with an internal stainless steel screen that can protect the components from environmental contamination, and can also keep contaminant like rust from being ejected at high speed into the work area. They have a typical noise reduction of 14 dB.

Pneumatic Valves:

  • Manual Valves allow for operators to turn on and off their system by hand. The full-flow ball valves range from ¼” NPT to 1 1/4” NPT in size and will not restrict flow.  EXAIR also offers a manual foot pedal valve for hands-free operations.  This ¼” NPT Foot Valve has a 3-way operation and works great if the operator has to use both hands in their process.
  • Solenoid Valves are a way to turn on and off the supply of compressed air electrically for automated systems. We offer solenoids in three different voltages; 110Vac, 240Vac, and 24Vdc.  EXAIR has a large range of flows with ports ranging from ¼” NPT to 1” NPT.  All models are UL listed and are CE and RoHS compliant.

Hardware:

  • Swivel Fittings are a great way to securely install and aim EXAIR nozzles. They are dynamic as they can be adjusted and set to a flow direction with 50-degrees of movement.  They are made from 303SS or 316SS for corrosion resistance with ports ranging from 4mm to 1” NPT.
  • Compressed Air Fittings are a nice arrangement to connect different compressed air items together. We offer a range of hex and close nipples, couplings, reducers, tees, elbows, crosses and bulk head fittings.  If you need a quick way to connect directly to your pneumatic system, we may have it on the shelf.
  • Magnetic Bases are designed for a solid mount to steel surfaces and for easy portability of your blow-off system to different locations. It has a 100 lb. (45.5Kg) pulling force to keep the blowing device attached firmly until you want to move it.  They can be mounted in a vertical or horizontal position.  EXAIR offers a single outlet Magnetic Base (for one blow-off device); a dual outlet Magnetic Base (for multiple blowing products); and a single outlet Swivel Magnetic Base (to offer more flexibility to orientation).  The bases come with a ¼ turn shut-off valve to easily turn on and off the compressed air to the EXAIR products.
  • Receiver Tanks are used to store compressed air. They can be used at the air compressor or as secondary reservoirs for intermittent demand.  They help your compressed air system with pressure variations and high demand loads.  EXAIR offers a model 9500-60 Receiver Tank that has a capacity of 60 gallons, is rated to 200 psig, and meets ASME pressure vessel code.

 

Hoses:

  • Conveying Hoses are used with our Air Operated Conveyors or Line Vacs. The hoses are made from a durable PVC semi-flexible hose with six different diameters from ¾” I.D. up to 3” I.D.  The conveyance hoses can slip easily to the ends of the Line Vacs or to tubes for an easy transition.  EXAIR can cut-to-length Conveying Hoses up to 50 feet (15m); in increments of 10 feet (3m).
  • Coiled Hoses get compressed air from the piping system to the EXAIR product. They are made of a durable abrasion-resistant nylon material that is 12 feet long (3.6 meters).  They have swivel fittings at the end to allow for easy uncoiling, and a spring strain relief to keep the hose from kinking.  The coiled design makes it easy to reach around the work area and retract back to the substation.  This will help to keep the hose off the ground where potential dangers could occur.  We offer 3 different connection sizes; 1/8” NPT, ¼” NPT, and 3/8” NPT.
  • Compressed Air Hoses is another way to supply EXAIR products. They are useful if you need to reach from overhead sources or around equipment.   They are made from a reinforced synthetic rubber in 3/8” I.D. and 1/2” I.D. diameters.  We can make specific lengths up to 50 feet (15m).  They are rated for 250 PSIG (17 bar) air pressure, and the hose material works well for long-lasting protection against ozone, weathering and temperatures up to 158oF (70oC).  They come standard with two male ends in ¼” NPT or ½” NPT.

    Flexible and durable, EXAIR Stay Set Hoses come in lengths from 6″ to 36″.
  • Stay Set Hoses give you that possibility of manually adjusting or re-adjusting Super Air Nozzles. The hose has a “memory” function; so, it will not creep or droop until you physically move it.  They work well to direct air flows in unique ways at specific target areas.  They can be used with Super Air Nozzles, Safety Air Guns and Blow-off Kits.  The Stay Set Hoses come in lengths from 6” (15cm) to 36” (91cm), and they are offered with ¼” NPT male on both ends or with a 1/8” NPT female and a ¼” NPT male connections.  These hoses are rated for 250 PSIG (17 bar) and are made from reinforced synthetic rubber.

Temperature Accessories:

  • The ETC, or Electronic Temperature Control, is a digital temperature controller with a LED screen for precision monitoring and adjusting temperatures in a Cabinet Cooler System. The controller has easy-to-use buttons to raise or lower the desired internal cabinet temperature.  Once set, the ETC will hold the temperature to +/- 1 oF (+/- 0.5 oC).  The LED displays the internal temperature for continuous monitoring.  The ETC comes complete with the controller and a solenoid valve in two different voltages, 120Vac and 240Vac.
  • The thermostat is a way to control a solenoid valve electrically to turn on/off a Cabinet Cooler System at a set temperature. It is preset at 95°F (35°C), but it can be adjusted to other desired temperatures.  It has an accuracy to hold the set temperature within +/- 2 °F (1 °C).  It can handle voltages from 24V to 240V, AC (50/60 Hz) or DC.  They are UL Recognized and CSA certified.

In todays fast-paced world, there is a need to get your devices operating as quickly as possible.  With EXAIR Accessories, they can help you to do that.  Not only will you have confidence, as you are using the items from the manufacturer, but it will minimize downtime, setup, and malfunctions that can occur if using other types of accessories.  If you would like to discuss the proper options with your EXAIR products, an Application Engineer will be happy to help you.

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

EXAIR Products: Silencing Mufflers Overview

OSHA Standard 29 CFR 1910.95(a), relating to permissible noise exposure levels, states that when employees are subjected to sounds in excess of 90 dBA, some type of control should be used to reduce the sound level. In an industrial setting, it’s very common to find the exhausting air from air operated devices such as actuators, diaphragm pumps or cylinders for example, to produce sound levels well above the allowable limits set forth in the Standard. EXAIR offers a variety of different Silencing Mufflers that help to reduce this  noise level, while also increasing operator safety.

 

Reclassifying Mufflers are available in 1/8″, 1/4″, 3/8″, 1/2″, 3/4″ and 1″ NPT sizes

EXAIR’s Reclassifying Mufflers offer noise reduction up to 35 dB and are available in sizes ranging from 1/8″ to 1″ NPT. These types of mufflers are often considered”dual-purpose” as they not only reduce the noise level but also remove oil from the exhaust airflow by incorporating a removable filter element.  The exhausting oil mist is reduced from 50 PPM (parts per million) to only 0.015 PPM, when the device is operated at 100 PSIG. In addition, there is a bowl on the bottom to capture any residual oil and a 1/4″ tube adaptor to allow for easy draining.

Sintered Bronze Mufflers are available in #10-32, 1/8″, 1/4″, 3/8″, 1/2″, 3/4″, 1″, 1-1/4″ and 1-1/2″ NPT sizes, as well as 1/2-20 UNF female for use with solenoid valves

Straight Through Mufflers are available in 1/4″, 3/8″ and 3/4″ MNPT x FNPT

Sintered Bronze Mufflers are a relatively low cost option, commonly used with air cylinders as they can be installed quick and easy. We offer 1o different sizes, ranging from #10-32 for small installations, up to 1-1/2″ NPT for larger scale applications. The noise reduction depends on the size of the muffler and back pressure, which can occur from dirt or particulate clogging the muffler, restricting the exhausting airflow from passing through the porous sintered bronze.

Our Straight Through Mufflers are made of corrosion resistant aluminum and are lined with a sound absorbing foam, capable of reducing noise levels up to 20 dB. We offer 3 different sizes, 1/4″, 3/8″ and 3/4″ NPT, with a male thread on one end and female thread on the other. We incorporate this muffler design into our Cold Guns and Adjustable Spot Coolers and they are commonly used with our Vortex Tubes, Cabinet Cooler® Systems and E-Vac® Vacuum Generators as well.

Heavy Duty Mufflers are available in 1/4″ and 3/8″ FNPT

Lastly, the Heavy Duty Mufflers feature an internal, 50 mesh stainless steel screen, to protect against contaminants in the airflow,  and a corrosion resistant aluminum outer shell. In most cases, the sound reduction can be as high as 14 dB and we offer 2 different sizes, 1/4″ and 3/8″ FNPT. These types of mufflers are regularly used on the hot air exhaust of our Vortex Tubes.

For help with product selection or to discuss a particular process, please contact one of our application engineers at 800-903-9247.

Justin Nicholl
Application Engineer
justinnicholl@exair.com
@EXAIR_JN