Compressed Air Quality Classes – ISO 8573-1

ISO 8573-1:2010 is the international standard for Air Quality Classes. It lays the ground rules for acceptable levels of pollutants, particulate, moisture, and oil in a compressed air source. 

Image Courtesy of  the Compressed Air Challenge

Though the standard has detailed standards for maximum particle size, maximum pressure dew point and maximum oil content for different industries and/or environments (see Slide show above) we can generalize a bit and express the levels of air quality like this:

Plant Air – general plant compressed air used for air tools, nozzles etc.
Instrument Air – found in laboratories, paint and powder coat booths, used for climate control.
Process Air – used in food and pharmaceutical applications, electronics applications.
Breathing Air – used for breathing respirators, breathing tanks and hospital air systems.

Achieving the different levels of air quality can be done with 3 basic types of filtration.
     1. Particulate – a filter element removes particles larger than the opening in the filter material. Typically done with particles greater than 1 micron.
     2. Coalescing – use different methods to capture the particles; 1) direct interception – works like a sieve, 2) Inertial impaction – collision with filter media fibers, 3) Diffusion – particles travel in a spiral motion and are captured in the filter media.
     3. Adsorption – the filter element holds the contaminants by molecular adhesion.

Filters
EXAIR FILTER SEPARATORS

The higher the class your air needs to be the more of these filtration methods you will use. Adsorption will remove more and finer particles than a simple particulate filter. And many applications will use a combination of these methods.

EXAIR products, all of which need a source of “clean, dry air” will operate very well utilizing a source of plant air and only a particulate filter. Your process, dictate if you need to supply additional filtration methods for better air quality. For example, an automotive plant using compressed air to blow parts off will not need the kind of filtration a food handling facility will need while blowing a food product off. If you are using a lubricated compressor or have lubricant in your compressed air lines from another source, you will want to use a coalescing oil removal filter.

EXAIR stocks 5 micron particulate filters which are properly sized for each individual product as an option for our customers if they choose. We also stock coalescing oil removal filters for customers who may need to remove oil from the air. Replacement filter elements are also available and should be replaced at least twice a year, depending on the quality of your air.

Oil Removal Filter
EXAIR Oil Removal Filter

Remember to ask about filtration if you have any concerns about your air quality. We can assist in sizing up the proper filters to get the air quality we recommend for proper operation and longevity of our products. 

If you would like to see how we might be able to improve your process or provide a solution for valuable savings, please contact one of our Application Engineers.

Jordan Shouse
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_JS

Image Courtesy of  the Compressed Air Challenge

Compressed Air Quality

In a recent conversation with an end user, we scratched the surface on compressed air quality.  In this case, the customer wanted to maintain their Super Air Knives as well as possible through preventative maintenance, and through supplying sufficient quality compressed air.  At present, they were unsure of the required compressed air quality for our products, and called EXAIR to seek direction.

When it comes to compressed air quality, ISO 8573 provides detailed standards on air quality classes for various levels of contaminants.  At times you may see a three digit code describing a filter, and this code refers to particulate, moisture, and lubricant classes of the filter (specified in that order).  The classes used to define these codes can be found below.

Compressed Air Quality ClassesISO 8573-1 Compressed Air Quality Classes

For example, if the application in question requires process air for assembly in a clean room with low particulate, low moisture, and low oil content, a filter rating of 1-1-1 would be desired.  EXAIR Automatic Drain Filter Separators are suitable to filter particulate to 5 micron, and our Oil Removal Filters are capable of trapping sub-micron particles down to 0.03 micron.  Supplying compressed air to these specifications is suitable for all EXAIR products.

Providing clean, dry compressed air is important to prevent contaminants from damaging components or manufactured products in an application.  Contaminants can enter the system at the intake of the compressor, through the compressor itself, or through the compressed air piping in the form of rust or pipe scale.

Determining the quality of air needed for an application can be done by considering the end use of the compressed air.  If the application requires plant air, there is no need to produce or maintain process air within the facility.  Compressed air quality can be tailored to the specific application at the point of use.

If you need help selecting the proper filters and compressed air conditioning equipment, contact and EXAIR Application Engineer.

Lee Evans
Application Engineer
LeeEvans@EXAIR.com
@EXAIR_LE