Compressed Air Distribution System, Keeping Pressure Drop to a Minimum

Compressed air is used to operate pneumatic systems within a facility, and it can be separated into three categories; the supply side, the demand side, and the distribution system.  The supply side is the air compressor, after-cooler, dryer, and receiver tank that produce and treat the compressed air.  They are generally located in a compressor room somewhere in the corner of the plant.  The demand side is the collection of devices that will use that compressed air to do “work”.  These pneumatic components are generally scattered throughout the facility.  To connect the supply side to the demand side, a compressed air distribution system is required.  Distribution systems are pipes which carry the compressed air from the compressor to the pneumatic devices.  For a sound compressed air system, the three sections have to work together to make an effective and efficient system.

An analogy that I like to use is to compare the compressed air system to an electrical system.  The air compressor would be considered the voltage source, and the pneumatic devices would be marked as light bulbs.  To connect the light bulbs to the voltage source, electrical wires are needed which will represent the distribution system.  If the gauge of the wire is too small to supply the light bulbs, the wire will heat up and a voltage drop will occur.  This heat is given off as wasted energy, and the light bulbs will be dim.  The same thing happens within a compressed air system.  If the piping size is too small, a pressure drop will occur.  This is also wasted energy.  In both types of systems, wasted energy is wasted money.  One of the largest systematic problems with compressed air systems is pressure drop.  If too large of a pressure loss occurs, the pneumatic equipment will not have enough power to operate effectively and efficiently.  As shown in the illustration below, you can see how the pressure decreases from the supply side to the demand side.  With a properly designed distribution system, energy can be saved; and, in referencing my analogy above, it will keep the lights on.

Pressure Drop Chart

To optimize the compressed air system, we need to reduce the amount of wasted energy.  This can be caused from leaks or pressure drop.   Leaks can be hidden and are typically located at connections within the distribution system.  In a poorly maintained system, a study found that 30% of the compressor capacity is lost through air leaks on average.  Even though leaks are the “silent killer” to a compressed air system, they can be found with the Ultrasonic Leak Detector

Pressure drop is more of a wide range issue.  It is based on restrictions, obstructions, and piping surface.  Out of these, restrictions are the most common types of pressure drops. The air flow is forced into small areas, causing high velocities.  The high velocity creates turbulent flow which increases the losses in air pressure.  Flow within the pipe is directly related to the velocity times the square of the diameter.  So, if you cut the I.D. of the pipe by one-half, the flow rating will be reduced by 25% of the original rating.  Restriction type of pressure drop can be found in different forms like small diameter pipes or tubing; restrictive fittings like quick disconnects and needle valves, and undersized filters, regulators and valves.

As a rule, air velocities will determine the correct pipe size for the distribution system.  It is beneficial to oversize the pipe to accommodate for any expansions in the future.  For header pipes, the velocities should not be more than 20 feet/sec (6 meter/sec).  For the distribution lines, the velocities should not exceed 30 feet/sec (9 meter/sec).  In following these simple rules, the distribution system can effectively supply the necessary compressed air from the supply side to the demand side.

To have a properly designed distribution system, the pressure drop should be less than 10% from the reservoir tank to the point-of-use.  By following the tips above, you can have the supply side, demand side, and distribution system working at peak efficiency.  If you would like to reduce waste even more, EXAIR offers a variety of efficient, safe, and effective compressed air products to fit within the demand side.  This will include the EXAIR Super Air Knives, Super Air Nozzles, and Safety Air Guns.  This would be the pneumatic equivalent of changing those incandescent light bulbs into LED light bulbs.  If you wish to go further in optimizing your system, an Application Engineer at EXAIR will be happy to help you. 

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

Photo:  Lightbulb by qimonoPixabay Licence

Pressure Drop Chart by Compressed Air Challenge Organization.

How-To Size Receiver Tanks and Why Use Them in Your Compressed Air System

Receiver Tank

My colleague, Lee Evans, wrote a blog about calculating the size of primary receiver tanks within a compressed air system.  (You can read it here: Receiver Tank Principle and Calculations).  I would like to expand a bit more about secondary receiver tanks.  They can be strategically placed throughout the plant to improve the operation of your compressed air system.  The primary receiver tanks help to protect the supply side when demands are high, and the secondary receiver tanks help pneumatic systems on the demand side for optimum performance.

Circuit Board

I like to compare the pneumatic system to an electrical system.  The receiver tanks are like capacitors.  They store energy produced by an air compressor like a capacitor stores energy from an electrical source.  If you have ever seen an electrical circuit board, you notice many capacitors with different sizes throughout the circuit board (reference photo above).  The reason for this is to have a ready source of energy to increase efficiency and speeds with the ebbs and flows of electrical signals.  The same can be said for a pneumatic system with secondary receiver tanks.

To tie this into the compressed air system, if you have an area that requires a high volume of compressed air intermittently, a secondary receiver tank would benefit this type of pneumatic setup.  With valves, cylinders, actuators, and pneumatic controls which turn on and off, it is important to have a ready source of stored “energy” nearby.

For calculating a minimum volume size for your secondary receiver tank, we can use Equation 1 below.  It is the same for sizing a primary receiver tank, but the scalars are slightly different.  The supply line to this tank will typically come from a header pipe that supplies the entire facility.  Generally, it is smaller in diameter; so, we have to look at the air supply that it can feed into the tank.  For example, a 1” NPT Schedule 40 Pipe at 100 PSIG can supply a maximum of 150 SCFM of air flow.  This value is used for Cap below.  C is the largest air demand for the machine or targeted area that will be using the tank.  If the C value is less than the Cap value, then a secondary tank is not needed.  If the Cap is below the C value, then we can calculate the smallest tank volume that would be needed.  The other value in the equation is the minimum tank pressure.  In most cases, a regulator is used to set the air pressure for the machine or area.  If the specification is 80 PSIG, then you would use this value as P2P1 is the header pressure that will be coming into the secondary tank.  With this collection of information, you can use Equation 1 to calculate the minimum tank volume.  So, any receiver tank with a larger volume would work as a secondary receiver tank.

Equation 1:

V = T * (C – Cap) * (Pa) / (P1-P2)

Where:

V – Volume of receiver tank (cubic feet)

T – Time interval (minutes)

C – Air demand for system (cubic feet per minute)

Cap – Supply value of inlet pipe (cubic feet per minute)

Pa – Absolute atmospheric pressure (PSIA)

P1 – Header Pressure (PSIG)

P2 – Regulated Pressure (PSIG)

If you find that your pneumatic devices are lacking in performance because the air pressure seems to drop during operation, you may need to add a secondary receiver to that system.  EXAIR stocks 60 Gallon tanks, model 9500-60, to add to those specific areas.  If you have any questions about using a receiver tank in your application, primary or secondary, you can contact an EXAIR Application Engineer.  We can restore your efficiency and speed back into your applications.

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

Photo: Circuit Board courtesy from T_Tide under Pixabay License