Compressed Air System Optimization – Where Do Receiver Tanks Fit?

SixSteps

The 5th step in the 6 steps to optimizing your compressed air system highlights the use of intermediate storage of compressed air near the point of use. Secondary, or intermediate Receiver tanks are installed in the distribution system to provide a source of compressed air close to the point of use, rather than relying on the output of the compressor.

Compressed air receiver tanks are an integral part to many compressed air distribution systems. Compressed air is stored at a high pressure after drying and filtration, but just upstream of point of use devices. The receiver tank is charged to a pressure higher than what is needed by the system, creating a favorable pressure differential to release compressed air when needed.

Think of a compressed air receiver tank as a “battery”. It stores the compressed air energy within a system to be used in periods of peak demand, helping to maintain a stable compressed air pressure. This improves the overall performance of the compressed air system and helps to prevent pressure drop.

receiver_tank

They can be strategically placed to provide a source of compressed air to intermittent high volume compressed air applications. Rather than having to pull from the compressor, a receiver tank can be sized to provide the short-term volume of air for a particular application. In a previous post, we’ve highlighted how to calculate the necessary receiver tank based on the air consumption and duration of the application.

EXAIR offers from stock a 60-gallon receiver tank designed specifically for these higher-usage intermittent types of applications. Model 9500-60 can be installed near the point of high demand so that you have an additional supply of compressed air available for a short duration. The tank comes with mounting feet and is designed to stand up vertically, saving floor space. The tank meets American Society of Mechanical Engineers (ASME) pressure vessel code.

Just this past Spring, EXAIR hosted a live webinar where we discuss how to size, install, and implement secondary storage in your plant’s distribution system. If you missed it, check it out here on our website hosted by my colleague, Russ Bowman.

If you have an application in your facility that’s draining your compressed air system, a receiver tank could be the ideal solution. Give us a call and one of our Application Engineers will be happy to help evaluate your process and determine the most suitably sized receiver tank.

Tyler Daniel, CCASS
Application Engineer
E-mail: TylerDaniel@EXAIR.com
Twitter: @EXAIR_TD

Secondary Receiver Tanks: Why Use Them and How to Size Them

Secondary receiver tanks can be strategically placed throughout the plant to improve the “ebbs and flows” of pneumatic demands.  The primary receiver tanks help to protect the supply side when demands are high, and the secondary receiver tanks help pneumatic systems on the demand side.  The purpose of secondary air storage is for dedicated end-use systems or for additional capacity at the end of distribution lines.  Essentially, it is easier and more efficient for compressed air to travel from a nearby source rather than traveling through long lengths of pipe.  With any high-demand events, it is beneficial to have additional storage.

As a comparison, I would like to relate a pneumatic system to an electrical system.  The receiver tanks would be like capacitors.  They store pressurized air like a capacitor stores energy from an electrical source.  If you have ever seen an electrical circuit board, you will notice many capacitors of different sizes throughout the circuit board.  The reason for this is to have a ready source of energy to increase efficiency and speeds with the ebbs and flows of electrical signals.  The same can be said for a pneumatic system with secondary receiver tanks.

To cover a current application, I had a customer that was looking at a model 1122108; 108” (2,743mm) Gen4 Super Ion Air Knife Kit.  The application was to remove static and debris from insulated panels for large refrigerated trailers.  They were worried about how much compressed air that it would use; and they were considering a blower-type system.  I went through the negative aspects of blower-type systems like loud noise levels, capital expense, high maintenance cost, large footprint, and ineffectiveness with turbulent air flows.  But, when you are limited to the amount of compressed air, it may seem difficult to get the best product for your application.  In looking at it another way, I asked him if the process was intermittent; and it was.  The cycle rate was 2 minutes on and 10 minutes off.  I was able to recommend a secondary tank to help ease the high demand for their compressed air system.

To calculate the volume size for your secondary receiver tank, we can use Equation 1 below.  It is the same for sizing a primary receiver tank, but the scalars are slightly different.  The supply line to this tank will typically come from a header pipe that supplies the entire facility.  Generally, it is smaller in diameter, so we have to look at the air supply that it can feed into the tank.  For example, a 1” NPT Schedule 40 pipe at 100 PSIG (7 bar) can supply a maximum of 150 SCFM (255 M3/hr) of air flow.  This value is used for Cap below.  The C value is the largest air demand for the machine or equipment that will be using the tank.  If the C value is less than the Cap value, then a secondary tank is not needed.  If the Cap is below the C value, then we can calculate the smallest tank volume that would be needed.  The other value in the equation is the minimum tank pressure.  In most cases, a regulator is used to set the air pressure for the machine or area.  If the specification is 80 PSIG (5.5 bar), then you would use this value as P2P1 is the header pressure that will be coming into the secondary tank.  With this collection of information, you can use Equation 1 to calculate the minimum tank volume

Equation 1:

V = T * (C – Cap) * (Pa) / (P1-P2)

Where:

V – Volume of receiver tank – Imperial (ft3) or SI (M3)

T – Time interval (minutes)

C – Air demand for system – Imperial (SCFM) or SI (M3/min)

Cap – Supply value of inlet pipe – Imperial (SCFM) or SI (M3/min)

Pa – Absolute atmospheric pressure – Imperial (PSIA) or SI (Bar)

P1 – Header Pressure – Imperial (PSIG) or SI (Bar)

P2 – Regulated Pressure – Imperial (PSIG) or SI (Bar)

For this customer above, I am still getting more details about their system.  But we went from a “we don’t have enough compressed air” to a “we can use a better solution with the Super Ion Air Knife”.  If you find that your compressed air system needs a boost for your pneumatic process, we may be able to recommend a secondary receiver for your system.  EXAIR does offer 60 gallon tanks, model 9500-60, to add to those specific areas.  If you have any questions about using a receiver tank in your application, you can contact an Application Engineer at EXAIR.  We will be happy to help.

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

How-To Size Receiver Tanks and Why Use Them in Your Compressed Air System

Receiver Tank

My colleague, Lee Evans, wrote a blog about calculating the size of primary receiver tanks within a compressed air system.  (You can read it here: Receiver Tank Principle and Calculations).  I would like to expand a bit more about secondary receiver tanks.  They can be strategically placed throughout the plant to improve the operation of your compressed air system.  The primary receiver tanks help to protect the supply side when demands are high, and the secondary receiver tanks help pneumatic systems on the demand side for optimum performance.

Circuit Board

I like to compare the pneumatic system to an electrical system.  The receiver tanks are like capacitors.  They store energy produced by an air compressor like a capacitor stores energy from an electrical source.  If you have ever seen an electrical circuit board, you notice many capacitors with different sizes throughout the circuit board (reference photo above).  The reason for this is to have a ready source of energy to increase efficiency and speeds with the ebbs and flows of electrical signals.  The same can be said for a pneumatic system with secondary receiver tanks.

To tie this into the compressed air system, if you have an area that requires a high volume of compressed air intermittently, a secondary receiver tank would benefit this type of pneumatic setup.  With valves, cylinders, actuators, and pneumatic controls which turn on and off, it is important to have a ready source of stored “energy” nearby.

For calculating a minimum volume size for your secondary receiver tank, we can use Equation 1 below.  It is the same for sizing a primary receiver tank, but the scalars are slightly different.  The supply line to this tank will typically come from a header pipe that supplies the entire facility.  Generally, it is smaller in diameter; so, we have to look at the air supply that it can feed into the tank.  For example, a 1” NPT Schedule 40 Pipe at 100 PSIG can supply a maximum of 150 SCFM of air flow.  This value is used for Cap below.  C is the largest air demand for the machine or targeted area that will be using the tank.  If the C value is less than the Cap value, then a secondary tank is not needed.  If the Cap is below the C value, then we can calculate the smallest tank volume that would be needed.  The other value in the equation is the minimum tank pressure.  In most cases, a regulator is used to set the air pressure for the machine or area.  If the specification is 80 PSIG, then you would use this value as P2P1 is the header pressure that will be coming into the secondary tank.  With this collection of information, you can use Equation 1 to calculate the minimum tank volume.  So, any receiver tank with a larger volume would work as a secondary receiver tank.

Equation 1:

V = T * (C – Cap) * (Pa) / (P1-P2)

Where:

V – Volume of receiver tank (cubic feet)

T – Time interval (minutes)

C – Air demand for system (cubic feet per minute)

Cap – Supply value of inlet pipe (cubic feet per minute)

Pa – Absolute atmospheric pressure (PSIA)

P1 – Header Pressure (PSIG)

P2 – Regulated Pressure (PSIG)

If you find that your pneumatic devices are lacking in performance because the air pressure seems to drop during operation, you may need to add a secondary receiver to that system.  EXAIR stocks 60 Gallon tanks, model 9500-60, to add to those specific areas.  If you have any questions about using a receiver tank in your application, primary or secondary, you can contact an EXAIR Application Engineer.  We can restore your efficiency and speed back into your applications.

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb