How to Calculate the Effects of Back Pressure on a Vortex Tube

Karate Chop

As any like-minded parent would do, I woke up this morning with the intention of scaring my son before breakfast.  As he came down the stairs, I tucked myself into an unlit corner of the adjacent room.  Just at the right moment I walked toward him really fast, not saying a word.  Got him!  He almost karate chopped me, but managed to see it was me before swinging.

So, that was the start of my day.  Now I’m helping people all over the world karate chop their compressed air use and integrate EXAIR products into their applications.  For example, I worked with our distributor in the U.K., Good Hand U.K. to determine the effective cooling capacity of an EXAIR Vortex Tube at higher than normal operating pressure, and with a back pressure above 5 PSIG.

In such a case, the cooling capacity of the Vortex Tube can be calculated as follows:

1.  Calculate the absolute pressure ratio with the back pressure

2.  Determine the effective pressure coming through the cold end with the non-typical back pressure

3.  Correlate the new, calculated effective pressure, to the Vortex Tube Performance Chart to determine the temperature drop (hold this value aside for use in later equation)

4.  Calculate the new air consumption based on the calculated effective pressure

5.  Multiply the new air consumption by the cold fraction value

6.  Enter these figures into the equation below to determine the new cooling capacity

BTU/hr. = K ΔTc (CFMc)

Where:  K = 1.0746

ΔTc = (100 – (Inlet compressed air temperature – Temperature drop created by Vortex Tube)

CFMc = Actual cold airflow from Vortex Tube under operating conditions

Using this information, we can calculate the effective cooling capacity of a Vortex Tube for any application.

For example, if we were to use a 3225 Vortex Tube in an application that desired a panel temperature of 100°F, with an operating pressure of 125 PSIG, compressed air temperature of 70°F, and a back pressure of 10 PSI, we can determine the cooling capacity as follows:

Calculate the absolute pressure ratio with the back pressure

(125PSIG + 14.7PSIA) / (10PSIG (backpressure) + 14.7 PSIA) = 5.66

Determine the effective pressure coming through the cold end with the non-typical back pressure

(X + 14.7) / 14.7 = 5.66

X + 14.7 = 83.2

X = 83.2 – 14.7

X = 68.5

This is the new, effective operating pressure of the Vortex Tube

Correlate the new, calculated effective pressure, to the Vortex Tube Performance Chart to determine the temperature drop (hold this value aside for use in later equation)

Considering a Cold Fraction value of 70%, we will achieve approximately 62°F in temperature drop

Calculate the new air consumption based on the calculated effective pressure

X / 25 SCFM = (68.5 PSIG + 14.7 PSIA) / (100 PSIG + 14.7 PSIA)

X / 25 SCFM = 83.2 / 114.7

X / 25 SCFM = 0.73

X = 18.25 SCFM

Multiply the new air consumption by the cold fraction value to determine volume of cold airflow

18.25 SCFM * 0.7 (70% Cold Fraction) = Actual volume of cold airflow from Vortex Tube

12.8 SCFM of actual cold air flow

Enter these figures into the equation below to determine the new cooling capacity

BTU/hr. = K ΔTc (CFMc)

BTU/hr. = 1.0746 * (100 – (70 – 62)) * 12.8

BTU/hr. = 1,265

So, in this case, the effective cooling capacity of the 3225 is decreased over 400 BTU/hr. simply due to back pressure.  For this reason, EXAIR Application Engineers always recommend to keep back pressure on a Vortex Tube below 5 PSI.  This ensures the best cooling and most efficient use of the compressed air.  This example also highlights the importance of compressed air pressure and compressed air temperature when using a Vortex Tube.

Lee Evans
Application Engineer
LeeEvans@EXAIR.com
@EXAIR_LE

Video Blog: Chip Trapper Filter Bag Installation/Replacement

I’ve taken a few phone calls from EXAIR customers using the Chip Trapper for the first time, needing clarification about the filter bag installation.  The video below shows how simple and quick it is to install and uninstall for replacement. Replacement filter bags are available in 1, 5, 25, 50, 100 and 200 micron filtration.

Lee Evans
Application Engineer
LeeEvans@EXAIR.com
@EXAIR_LE

How to Size Pipes for Your Compressed Air System

Most facility’s compressed air systems have evolved over time. A spur added here a spur added there. Eventually pressure drop issues develop. Common practice is to increase the air pressure at the compressor. While it may address the symptom it does not address the problem and is very costly. For every 2 PSI increase in pressure requires 1% more energy.

A properly designed system will be a loop with spurs. This will ensure all airsystem

drops will share the air equally. The header loop should be able to carry all the air the compressor is capable of producing.  Best practices suggest the distribution header should be sized to allow an air velocity not to exceed 30 ft/second. The formula to calculate this is:

A =    144 * Q * Pa
       V *60 x (Pd +Pa)

Pipe Diameter = √ (A*4/3.14)

Where:

A = cross sectional area if the pipe bore in square inches or ∏ x diameter squared / 4
Q = Flow rate SCFM
Pa = Prevailing absolute pressure. Sea level is 14.7
Pd = compressor gauge pressure or psig.
V = Design pipe velocity ft/sec

Example: Size a header for 500 SCFM at 100 PSI at an elevation at sea level

A = 144 x 500 x 14.7 / 30 x 60 (100 + 14.7) = 5.13  square inches

Pipe diameter then is square root of  (5.13 * 4) / 3.14 = 2.56″

So an 2.56″  internal diameter pipe would be the proper size header.

The same formula can be used to calculate the sizes of the drops. In this case you would use the demand flow rate for Q.

Joe Panfalone
Application Engineer
Phone (513) 671-3322
Fax (513) 671-3363
Web: http://www.exair.com
Twitter: http://www.twitter.com/exair_jp
Facebook: http://www.facebook.com/exair

Video Blog: How to Rebuild an EXAIR Safety Air Gun

While EXAIR’s safety air guns are of robust design, they do see some harsh environments and eventually some of the moving parts can wear out. EXAIR offers rebuild kits.

  • For the Soft Grip Safety Air Gun use part #1901A or #1901
  • For the Heavy Duty Safety Air Gun use part #1902

Here is a video on how to install the new components.


If you need help give our application engineers a call 1-800-903-9247

Joe Panfalone
Application Engineer
Phone (513) 671-3322
Fax   (513) 671-3363
Web: www.exair.com
Twitter: www.twitter.com/exair_jp
Facebook: http://www.facebook.com/exair