Hazardous Location AND Overheating Electronics? We Have You Covered!

Here in Ohio, we like to think we know a lot about the weather. Did you know there are more than 4 seasons? Heck, we have at least two Winters, and then a Pre-Summer, Spring, Summer, Heat is still coming – make it stop season, and Fall. Don’t forget the construction season where the lovely orange cones and barrels bloom on every major roadway, and then we also like to throw in brood weeks for the cicadas every now and then. Yeah, we get a full gambit of weather and the past week has brought out some heat. I know this isn’t just Ohio, we get calls from around the globe of atmospheric conditions that have caused issues within control panels. Some of these panels are in areas where the No Smoking sign is more than just a suggestion to better your health.

1 – Dust Explosion

That’s right, there are areas in manufacturing facilities that are governed by the standard due to a variety of conditions resulting in what is known as Hazardous Locations. NFPA and UL have a list of standards breaking these down into separate Classes, Divisions, and Temperature Classes. If you want all the details, the NFPA code is around 908 pages, cover to cover. The Classified UL mark shown below is one way of knowing that a product has been tested to these stringent standards and is okay to use in clearly marked environments.

UL Classified Markings

EXAIR offers Cabinet Cooler Systems that will meet these stringent standards and keep your enclosures cool in order to keep your production up and running. The top three tiers that we meet are:

  • Class I Div 1, Groups A, B, C and D
  • Class II Div 1, Groups E, F and G
  • Class III

The HazLoc Cabinet Cooler Systems are available in 8 different cooling capacities from 1,000 Btu/hr to 5,600 Btu/hr. and are manufactured to work in conjunction with a purged and pressurized control system. As well as with or without thermostatic control.

EXAIR’s Hazarous Location Cabinet Cooler Systems maintain Type NEMA 4/4X Integrity and are CE Compliant.

If you would like help sizing the correct system for your electrical panels, feel free to use the link, or contact an Application Engineer to discuss the applications and get one sized while on the phone with us.

Brian Farno
Application Engineer
BrianFarno@EXAIR.com
@EXAIR_BF

1 – Dust explosion 05.jpg, Hans-Peter Scholz, October 7, 2009, retrieved from https://commons.wikimedia.org/wiki/File:Dust_explosion_05.jpg

Hazardous Location Cabinet Coolers

Last year was a big year for EXAIR’s Cabinet Cooling product line, in November  we launched our first Hazardous Location Cabinet CoolersEXAIR has always been a leading supplier in compressed air-based Cabinet Coolers, now we have expanded on that to work in the most high-risk conditions.

When a Hazardous Location Cabinet Cooler is used in conjunction with a purge system, they will keep electrical equipment at the desired operating temperature to protect and lengthen the lifetime of pricey controls and power supplies.

hazloc_illLsr-800w
Hazardous Location Cabinet Cooler

 

Electrical equipment can cause explosions in certain atmospheres. Equipment used in areas where explosive concentrations of dusts or vapors may exist must be equipped with special wiring and other electrical components for safety purposes. Hazardous (classified) locations such as these might exist in aircraft hangars, gasoline stations, paint-finishing locations or grain bins. EXAIR’s Hazardous Location Cabinet Coolers have been approved and tested by UL for use in the following areas:

classified_cULus_360x283
UL Approved and Tested

Class I Div 1&2 – Groups A, B, C, and D

  • Class I Areas refer to the presence of flammable gases or vapors in quantities sufficient to produce explosive or ignitable mixtures. Class I Div 1 will have ignitable concentrations of flammable gases present during the course of normal operations. This is level of approval is one that differentiates the EXAIR Hazardous Location Cabinet Coolers from much of the competition. Class 1 Div 2 areas will have flammable gasses or vapors present only in the event of an accident or during unusual operating conditions.

Class II Div 1&2 – Groups E, F, and G

  • Class II areas are locations in which combustible dust may exist. The end user shall avoid installation of the device in a Class II environment where dust may be readily disturbed from the exhausts of the Hazardous Location Cabinet Cooler. Any dust formed in the vicinity of the cooler must be cleaned regularly.

Class III

  • Class III areas are locations that will have ignitable fibers or flyings present. This is common within the textile industry.

The Cabinet Cooler also carries a temperature rating of T3C, meaning it cannot be installed near any materials that could auto-ignite at temperatures in excess of 320°F.

The Hazardous Location Cabinet Cooler is available in (8) different cooling capacities ranging from 1,000 Btu/hr – 5,600 Btu/hr. The Cabinet Cooler is the best solution for protecting your sensitive electronics from heat, dirt, and moisture. With Nema 4/4X systems available, the Hazardous Location Cabinet Coolers will keep the cabinet cool without compromising the integrity of the enclosure.

If you’ve got an electrical cabinet installed within a hazardous location, fill out the Cabinet Cooler Sizing Guide and allow an EXAIR Application Engineer to determine the most suitable model for you.

Jordan Shouse
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_JS

NEW From EXAIR! The Hazardous Location Cabinet Cooler – For Use In Classified Areas

EXAIR is always focused on releasing new products and improving on existing product lines, and 2018 has been no different! Earlier on this year we introduced the New Super Air Scraper as an accessory to our 2” Flat Nozzles and Safety Air Guns. Just last month, EXAIR has also introduced a new line of products to the Cabinet Cooler family: The Hazardous Location Cabinet Cooler.

hazloc_illLsr-800w

EXAIR’s Hazardous Location Cabinet Coolers are engineered for use with purged (not included) electrical enclosures. The HazLoc Cabinet Coolers are not purged and pressurized control systems and should not be relied upon nor used in place of a purged and pressurized controller. They are meant for use in conjunction with a purged and pressurized control system. These systems have been approved and tested by UL for use in the following areas:

Class I Div 1&2 – Groups A, B, C, and D

  • Class I Areas refer to the presence of flammable gases or vapors in quantities sufficient to produce explosive or ignitable mixtures. Class I Div 1 will have ignitable concentrations of flammable gases present during the course of normal operations. This is level of approval is one that differentiates the EXAIR Hazardous Location Cabinet Coolers from much of the competition. Class 1 Div 2 areas will have flammable gasses or vapors present only in the event of an accident or during unusual operating conditions.

Class II Div 1&2 – Groups E, F, and G

  • Class II areas are locations in which combustible dust may exist. The end user shall avoid installation of the device in a Class II environment where dust may be readily disturbed from the exhausts of the Hazardous Location Cabinet Cooler. Any dust formed in the vicinity of the cooler must be cleaned regularly.

Class III

  • Class III areas are locations that will have ignitable fibers or flyings present. This is common within the textile industry.

The Cabinet Cooler also carries a temperature rating of T3C, meaning it cannot be installed near any materials that could auto-ignite at temperatures in excess of 320°F. For a comprehensive list and description of all of the various Classified areas, check out the UL website.

The Hazardous Location Cabinet Cooler is available in (8) different cooling capacities ranging from 1,000 Btu/hr – 5,600 Btu/hr. The Cabinet Cooler is the best solution for protecting your sensitive electronics from heat, dirt, and moisture. With Nema 4/4X systems available, the Hazardous Location Cabinet Coolers will keep the cabinet cool without compromising the integrity of the enclosure.

If you’ve got an electrical cabinet installed within a hazardous location, fill out the Cabinet Cooler Sizing Guide and allow an EXAIR Application Engineer to determine the most suitable model for you.

Tyler Daniel
Application Engineer
E-mail: TylerDaniel@exair.com
Twitter: @EXAIR_TD