Hazardous Location Cabinet Coolers

Last year was a big year for EXAIR’s Cabinet Cooling product line, in November  we launched our first Hazardous Location Cabinet CoolersEXAIR has always been a leading supplier in compressed air-based Cabinet Coolers, now we have expanded on that to work in the most high-risk conditions.

When a Hazardous Location Cabinet Cooler is used in conjunction with a purge system, they will keep electrical equipment at the desired operating temperature to protect and lengthen the lifetime of pricey controls and power supplies.

hazloc_illLsr-800w
Hazardous Location Cabinet Cooler

 

Electrical equipment can cause explosions in certain atmospheres. Equipment used in areas where explosive concentrations of dusts or vapors may exist must be equipped with special wiring and other electrical components for safety purposes. Hazardous (classified) locations such as these might exist in aircraft hangars, gasoline stations, paint-finishing locations or grain bins. EXAIR’s Hazardous Location Cabinet Coolers have been approved and tested by UL for use in the following areas:

classified_cULus_360x283
UL Approved and Tested

Class I Div 1&2 – Groups A, B, C, and D

  • Class I Areas refer to the presence of flammable gases or vapors in quantities sufficient to produce explosive or ignitable mixtures. Class I Div 1 will have ignitable concentrations of flammable gases present during the course of normal operations. This is level of approval is one that differentiates the EXAIR Hazardous Location Cabinet Coolers from much of the competition. Class 1 Div 2 areas will have flammable gasses or vapors present only in the event of an accident or during unusual operating conditions.

Class II Div 1&2 – Groups E, F, and G

  • Class II areas are locations in which combustible dust may exist. The end user shall avoid installation of the device in a Class II environment where dust may be readily disturbed from the exhausts of the Hazardous Location Cabinet Cooler. Any dust formed in the vicinity of the cooler must be cleaned regularly.

Class III

  • Class III areas are locations that will have ignitable fibers or flyings present. This is common within the textile industry.

The Cabinet Cooler also carries a temperature rating of T3C, meaning it cannot be installed near any materials that could auto-ignite at temperatures in excess of 320°F.

The Hazardous Location Cabinet Cooler is available in (8) different cooling capacities ranging from 1,000 Btu/hr – 5,600 Btu/hr. The Cabinet Cooler is the best solution for protecting your sensitive electronics from heat, dirt, and moisture. With Nema 4/4X systems available, the Hazardous Location Cabinet Coolers will keep the cabinet cool without compromising the integrity of the enclosure.

If you’ve got an electrical cabinet installed within a hazardous location, fill out the Cabinet Cooler Sizing Guide and allow an EXAIR Application Engineer to determine the most suitable model for you.

Jordan Shouse
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_JS

UL Classified Certification for HazLoc Cabinet Coolers

Although history only records back so far, I am certain (based on my experiences with sharp and heavy objects) that humans have been injuring themselves with tools, and the stuff they make with them, since the beginning of time.  In fact, recorded history DOES bear this out…the famous Code of Hammurabi (circa 1750 B.C.) set specific amounts of compensation for specific injuries, as did laws from all over the ancient world, from the empires of Rome to China.  Since then, we’ve come a long way in regulating safety not only for the worker in the workplace, but in public places, homes, and workplaces where manufactured products are used.

UL LLC (or Underwriters Laboratories, as they were known throughout the 20th Century) is a safety consulting & certification company founded in 1894 by an electrical engineer named William Henry Merrill.  A year earlier, an insurance company hired Merrill to perform a risk assessment and investigation of new potential clients…George Westinghouse and Nikola Tesla, the proprietors of the Palace of Electricity at the 1893 Chicago World’s Fair.  It was this experience that made him realize the potential for such an agency to test and set standards for product safety at the dawn of a new age of technology development.  And 120 years on, the benefits in safety & protection have been proven many times over.

If a product or device carries one of these markings, it’s been evaluated for safety by top professionals in the field.

One of the more critical accreditations that a manufacturer can receive for a product is the UL Classified Mark.  This differs from other markings (like the ones shown above for Certified, Listed, or Recognized) in that Classification means that samples of the product were tested & evaluated with respect to certain properties of the product.

EXAIR’s new Hazardous Location Cabinet Cooler Systems bear the UL Classified Mark.  This means they meet the stringent UL requirements for installation on purged electrical enclosures in specific classified areas:

  • Class I Div 1, Groups A, B, C and D
  • Class II Div 1, Groups E, F and G
  • Class III
EXAIR Hazardous Location Cabinet Cooler Systems maintain NEMA 4/4X Integrity and are CE Compliant.

When choosing products for use in classified areas, it’s critical to ensure safety through compliance, and the HazLoc Cabinet Cooler Systems allow you to do that, with simplicity and reliability.  If you’d like to discuss an enclosure cooling application, in or out of a classified area, give me a call.

Russ Bowman
Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook

NEW From EXAIR! The Hazardous Location Cabinet Cooler – For Use In Classified Areas

EXAIR is always focused on releasing new products and improving on existing product lines, and 2018 has been no different! Earlier on this year we introduced the New Super Air Scraper as an accessory to our 2” Flat Nozzles and Safety Air Guns. Just last month, EXAIR has also introduced a new line of products to the Cabinet Cooler family: The Hazardous Location Cabinet Cooler.

hazloc_illLsr-800w

EXAIR’s Hazardous Location Cabinet Coolers are engineered for use with purged (not included) electrical enclosures. The HazLoc Cabinet Coolers are not purged and pressurized control systems and should not be relied upon nor used in place of a purged and pressurized controller. They are meant for use in conjunction with a purged and pressurized control system. These systems have been approved and tested by UL for use in the following areas:

Class I Div 1&2 – Groups A, B, C, and D

  • Class I Areas refer to the presence of flammable gases or vapors in quantities sufficient to produce explosive or ignitable mixtures. Class I Div 1 will have ignitable concentrations of flammable gases present during the course of normal operations. This is level of approval is one that differentiates the EXAIR Hazardous Location Cabinet Coolers from much of the competition. Class 1 Div 2 areas will have flammable gasses or vapors present only in the event of an accident or during unusual operating conditions.

Class II Div 1&2 – Groups E, F, and G

  • Class II areas are locations in which combustible dust may exist. The end user shall avoid installation of the device in a Class II environment where dust may be readily disturbed from the exhausts of the Hazardous Location Cabinet Cooler. Any dust formed in the vicinity of the cooler must be cleaned regularly.

Class III

  • Class III areas are locations that will have ignitable fibers or flyings present. This is common within the textile industry.

The Cabinet Cooler also carries a temperature rating of T3C, meaning it cannot be installed near any materials that could auto-ignite at temperatures in excess of 320°F. For a comprehensive list and description of all of the various Classified areas, check out the UL website.

The Hazardous Location Cabinet Cooler is available in (8) different cooling capacities ranging from 1,000 Btu/hr – 5,600 Btu/hr. The Cabinet Cooler is the best solution for protecting your sensitive electronics from heat, dirt, and moisture. With Nema 4/4X systems available, the Hazardous Location Cabinet Coolers will keep the cabinet cool without compromising the integrity of the enclosure.

If you’ve got an electrical cabinet installed within a hazardous location, fill out the Cabinet Cooler Sizing Guide and allow an EXAIR Application Engineer to determine the most suitable model for you.

Tyler Daniel
Application Engineer
E-mail: TylerDaniel@exair.com
Twitter: @EXAIR_TD