UL Certifications Explained

If a product or device carries one of these markings, it’s been evaluated for safety by top professionals in the field.

You probably walked by many items in a department store that had a UL mark, and not even noticed.   What does this mark mean?  The Underwriters Laboratories (UL) is a third-party organization that verifies that products are safe for use.  They have been around for more than 100 years, and they are very important for checking the design of electrical systems.  In order to receive the UL stamp, it has to pass stringent tests for conformance and safety, and they register the items on a database for users to review.  EXAIR uses this service for our products.  EXAIR stands behind our products with the Underwriters Laboratories recognition.  I will go over the products that EXAIR manufacturers and the type of UL marks that we have. 

There are three main types of UL marks; UL Listed, UL Recognized, and UL Listed Classified. 

UL Listed:  All EXAIR Cabinet Coolers are UL Listed!  It is important to note that EXAIR was the first to ensure that your electrical panel’s NEMA rating remained when using our Cabinet Cooler Systems.  Our products underwent numerous tests and scenarios to verify that an operator will be safe during normal operations.   The tests for the Cabinet Cooler Systems included environmental exposure for the given NEMA type along with many other tests.  When you place a Cabinet Cooler onto your electrical panel, the degree of protection is not affected.  Our Cabinet Cooler Systems come in NEMA 12, NEMA 4, and NEMA 4X.  They are designed to keep the electrical components inside cool; stopping unnecessary shutdowns from excessive heat.  With the UL listed mark, the Underwriters Laboratories have deemed these products safe for operation throughout the US and Canada per their standards.  

UL Recognized:  The Gen4 Static Eliminators and Power Supplies are UL Recognized.  UL Recognition is most often seen with components, in a form of power supplies or circuit boards, that are used to power other parts. UL Recognition ensures the safety and efficiency of machinery used by operators. In other words, it certifies that a component within a larger instrument meets UL standards.  The Gen4 Power Supplies are used to generate ions with our Gen4 Static Eliminators.  These ions will remove any type of static that can cause jams, misalignment, and harmful shocks.  We offer two types of Power Supplies, a two port and a 4 port, to operate eight different styles of Static Eliminators.  And together, you can make sure that your operators are safe when using our products to remove static nuisances.    

UL Listed Classified: The UL Classified certification means that the product has been evaluated, tested and passed the test for being safe when installed within classified areas. This includes a large range of hazardous locations which according to OSHA is defined as an explosive atmosphere due to the presence of flammable gases (Class I), combustible dusts (Class II), or ignitable fibers and flyings (Class III).  Unlike the Cabinet Coolers above, the HazLoc Cabinet Cooler went through a more stringent test to operate in all classified areas.  Used with a purge system, the HazLoc Cabinet Cooler keep the electronics from faulting due to over-temp. 

Here are our registration number with UL for you to review:

Cabinet Cooler Systems:                                        E182292

Static Neutralizing Equipment:                             E138256

Hazardous Locations Cabinet Cooler Systems:     E498880

It is widely known that machines are the lifeblood of any business. Taking steps to protect your investment and your operators that use the equipment is essential for long-term success of a company.  The UL certification will give you that peace of mind.  Lastly, since UL is a third-party service, you can be confident that the UL label is a true sign of safety and longevity within electrical systems.  If you would like to discuss more about our UL listed products for removing static or cooling electronics, an Application Engineer at EXAIR will be happy to help you. 

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

The UL Classified Mark

Safety, it’s a word that gets tossed around in both the work place and in your daily life.  From the beginning of time, people have been injuring themselves at work and at home. Today’s well known phrases “Hey watch this” or “Hold my Beer” became a popular way to say I am about to do something crazy and stupid and I know it. As someone who enjoys the outdoors and the thrills of extreme sports, I can attest from both personal experience and the experiences of those around me that people don’t make smart decisions. At a young age I had a laundry list of injuries longer than most people 10 years older than me. But even in the craziest of my stunts (i.e. running an 18’ waterfall in a kayak) there is a level of safety that is put into place. That safety can come from the practice it takes to develop higher skill (experience) or from the knowledge of experts around you. 

Companies have been trying to figure out ways to make offices and manufacturing plants a zero-incident environment for a long time. A lot of safety departments call this journey the Road to Zero and track each incident closely. Aside from policies and equipment modifications there are consulting and certification companies that focus solely on the safety of products used in manufacturing and production plants. One of the more prominent companies in the U.S. is UL or Underwriters Laboratories; this company was founded by an electrical engineer named William Henry Merrill in 1894. In 1893 an insurance company hired Merrill to perform a risk assessment on new potential clients, George Westinghouse and Nikola Tesla. This led him to realize the potential for an agency to test and set standards for product safety.

One example of a sought after and critical accreditation is the UL Classified Mark. The UL Classified certification means that the product has been evaluated, tested and passed the test for being safe when installed within classified areas. This includes a large range of hazardous locations which according to OSHA is defined as an explosive atmosphere due to the presence of flammable fluids (Class 1), combustible dusts (Class 2), or ignitable fibers and flyings (Class 3). These areas include everything from chemical plants to the food industry.

EXAIR’s Hazardous Location Cabinet Cooler

EXAIR has a Cabinet Cooler that can be used in these Hazardous Locations and earned the UL Classified Mark. The Hazardous Location Cabinet Cooler Systems are designed to be used with purged and pressurized systems in the following locations:

Class I Div 1, Groups A, B, C, and D
Class II Div 1, Groups E, F, and G
Class III

This means that the Hazardous Location Cabinet Coolers can be used in areas with explosive gas and vapors, combustible dusts, or ignitable fibers. 

If you have any questions about compressed air systems or want more information on any of EXAIR’s products, give us a call, we have a team of Application Engineers ready to answer your questions and recommend a solution for your applications.

Cody Biehle
Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook

Class II Hazardous Areas, Groups E, F and G Explained

The National Electrical Code, or NEC, classifies hazardous areas into three different categories; Class I, Class II, and Class III.  To use equipment in or around these types of areas, caution has to be taken to not cause an explosion or fire.  In the U.S., the Underwriter’s Laboratory, UL, can certify products that can be used safely in these hazardous areas.  EXAIR received our UL Classification for our HazLoc Cabinet Cooler® Systems.  Under certain guidelines, the HazLoc Cabinet Coolers can be used in Class I areas for gases and vapors, Class II areas for flammable dust, and Class III areas for ignitable fibers and flyings.  In this blog, I will cover the Class II hazardous areas.

First, HazLoc Cabinet Coolers are designed to keep electrical components cool during summer months and higher ambient conditions.  They are powered by an EXAIR Vortex Tube which only uses compressed air to generate cold air.  They do not have any moving parts, refrigerant, or refrigerant compressors to fail.  These simple, but effective, cooling devices can be used in the toughest of environments.  With the Vortex Tube as the “engine”, the reliability of the EXAIR HazLoc Cabinet Cooler is unmatched.  It is an easy choice for cooling electrical panels and reduce premature shutdowns.

For a fire to occur, we only need three things as described by the fire triangle; oxygen, fuel, and an ignition source.  For an explosion, we need two other conditions, dust concentration and confinement.  For a Class II area, the fuel is combustible dusts.  “Combustible dusts are fine particles that present an explosion hazard when suspended in air under certain conditions.”1  By NEC standards, dust is categorized into three different groups.  Group E is for metal dust.  This will include aluminum and magnesium dust.   Group F is for carbonaceous dust like charcoal, coal, and carbon black.  And Group G is for non-conductive dust like flour, grain, and plastic.  These fine particles can float and collect on equipment in the surrounding areas.  This collection of material can ignite and cause a fire from a spark or a heat source.  If they are contained like within a panel, then there is a possibility of an explosion.

The ignition source (the second leg of the fire triangle above) is generally from electrical equipment, heat, and static.  Arcs and sparks from motors, contacts, and switches can ignite Class II materials; as well as, high temperatures from equipment.  NEC and UL segregate this hazardous location into two divisions.  Class II Division 1 is in an area where dust material is handled, manufactured, or used.  Class II Division 2 is where the dust material is stored or handled other than in the process of manufacturing.  In both divisions, it is important to protect your electrical systems from these particles “floating” in the surrounding air.

The EXAIR HazLoc Cabinet Cooler Systems are designed to keep your electrical panels cool within hazardous areas like Class II above.  Because system shutdowns from electrical components overheating are costly and potentially dangerous, you can install a HazLoc Cabinet Cooler System without sacrificing your panel’s integrity.  If you would like to discuss in more detail about the different types of EXAIR HazLoc Cabinet Coolers, an Application Engineer at EXAIR will be happy to help you.

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

 

Note 1: Osha.gov publication

Photo: Inflammable Sign Hazardous Symbol European by Clker-Free-Vector-Images.  Pixabay License

UL Classified Certification for HazLoc Cabinet Coolers

Although history only records back so far, I am certain (based on my experiences with sharp and heavy objects) that humans have been injuring themselves with tools, and the stuff they make with them, since the beginning of time.  In fact, recorded history DOES bear this out…the famous Code of Hammurabi (circa 1750 B.C.) set specific amounts of compensation for specific injuries, as did laws from all over the ancient world, from the empires of Rome to China.  Since then, we’ve come a long way in regulating safety not only for the worker in the workplace, but in public places, homes, and workplaces where manufactured products are used.

UL LLC (or Underwriters Laboratories, as they were known throughout the 20th Century) is a safety consulting & certification company founded in 1894 by an electrical engineer named William Henry Merrill.  A year earlier, an insurance company hired Merrill to perform a risk assessment and investigation of new potential clients…George Westinghouse and Nikola Tesla, the proprietors of the Palace of Electricity at the 1893 Chicago World’s Fair.  It was this experience that made him realize the potential for such an agency to test and set standards for product safety at the dawn of a new age of technology development.  And 120 years on, the benefits in safety & protection have been proven many times over.

If a product or device carries one of these markings, it’s been evaluated for safety by top professionals in the field.

One of the more critical accreditations that a manufacturer can receive for a product is the UL Classified Mark.  This differs from other markings (like the ones shown above for Certified, Listed, or Recognized) in that Classification means that samples of the product were tested & evaluated with respect to certain properties of the product.

EXAIR’s new Hazardous Location Cabinet Cooler Systems bear the UL Classified Mark.  This means they meet the stringent UL requirements for installation on purged electrical enclosures in specific classified areas:

  • Class I Div 1, Groups A, B, C and D
  • Class II Div 1, Groups E, F and G
  • Class III

EXAIR Hazardous Location Cabinet Cooler Systems maintain NEMA 4/4X Integrity and are CE Compliant.

When choosing products for use in classified areas, it’s critical to ensure safety through compliance, and the HazLoc Cabinet Cooler Systems allow you to do that, with simplicity and reliability.  If you’d like to discuss an enclosure cooling application, in or out of a classified area, give me a call.

Russ Bowman
Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook