Achieve the Perfect Temperature with EXAIR’s Adjustable Spot Cooler

EXAIR’s Adjustable Spot Cooler is an ideal fit for those who need the ability to adjust the temperature of their spot cooling solution. This user-friendly tool is available right out of the box with the necessary accessories to allow you to quickly install and implement the solution. It can be great for dry-machining processes or applications where you’re looking to replace a standard coolant-based method of cooling.

If that sounds like something you’re looking for, then the Adjustable Spot Cooler could be an excellent product for optimizing your processes. EXAIR’s Adjustable Spot Cooler incorporates Vortex Tube technology to produce temperatures ranging from -30°F – +70°F. A Vortex Tube works by imparting a rapid spinning motion to the supplied compressed air. This airflow makes its way to the end of the tube where it is forced to abruptly change direction. It is during this change of direction that energy is given off in the form of heat. The hot air then exits the tube from the hot end, while cold air exits the other end of the tube. As the valve is opened to allow more air to exhaust from the hot end, the temperature at the cold end will decrease. At a sound level of just 73 dBA when operated at 100 psig and a stock generator installed, this compact cooler will keep your operation clean and dry without causing unnecessarily high noise levels.

When looking at a Vortex Tube based solution, the variety of options can sometimes be daunting. This is where the Adjustable Spot Cooler shines. Through a simple turn of the control knob, you can easily adjust the temperature and cold fraction of the unit. Additionally, the kits come with (2) extra generators (15-H and 30-H) that can be swapped out for the stock generator for more/less cooling power and air consumption. The 15-H generator will deliver up to 1,000 Btu/hr of cooling capacity and the 30-H will provide up to 2,000 Btu/hr of cooling capacity. We have (2) different kits available, the Model 3825 Single Point and the Model 3925 Dual Point Kit. The 3825 is recommended for use in applications where you’re cooling a small surface such as solder joints, hot melts, or drilled plastics. The 3925 system is better served when heat is generated over a larger surface area, such as saw blade cooling. The kits use a flexible Loc-Line hose to allow you to precisely position the cold airflow onto your target. The Adjustable Spot Cooler provides easy mounting with a swivel magnetic base, allowing you to position the cold air flow directly at the most critical point where heat is being generated.

If you’re tired of cleaning up your coolant or have an application that requires dry machining, get one of the Adjustable Spot Cooler systems on order today. They’re in stock ready to ship the same day with an order received by 2:00 ET!

Tyler Daniel, CCASS

Application Engineer

E-mail: TylerDaniel@exair.com

X: @EXAIR_TD

Hot Off The Press (Release): Adjustable Spot Cooler Provides Precise Industrial Cooling

I got a new cell phone a few months ago. It was my first ‘upgrade’ in quite some time, and while it has some neat features (along with a bunch of stuff I’ll NEVER use), there was one glaring omission: a 1/8″ port for the cord of my trusty earbuds. I even took the protective case off, looking for it. After just barely managing to get the case back on, I bought myself my first ever wireless earbuds. After scanning the ‘quick reference’ guide, I steeled my reserve for the long & arduous process of getting them up and running. To my pleasant surprise, they were fully charged, and, right out of the case, started pairing with my new cell phone. I was drowning out the sound of my lawnmower to 1970s Heavy Metal in no time!

You know what else is ready to go, right out of the box? EXAIR’s Adjustable Spot Cooler System, that’s what. OK; it doesn’t automatically connect itself to your compressed air system, but once you hook an air hose up to it, it makes a flow of cold air instantly. With the Temperature Control Valve, you can change the cold air flow and temperature just as instantly. If the 25 SCFM Generator that comes installed doesn’t make enough flow – or if it makes too much – the Adjustable Spot Cooler System comes with two more Generators (15 SCFM and 30 SCFM) that’ll put it into a whole new performance band.

The Adjustable Spot Cooler incorporates a vortex tube to convert an ordinary supply of compressed air (1) into two low pressure streams, one hot and one cold. With the turn of a knob, the temperature control valve (2) allows some hot air to flow through a muffling sleeve and out the hot air exhaust (3). The opposite end provides a cold airstream (4) that is muffled and discharged through the flexible hose, which directs it to the point of use. The swivel magnetic base (5) provides easy mounting and portability.

I was excited to hear that the Adjustable Spot Coolers were the focus of our latest Press Release. With their ease of installation and operation, they’re ideal for a wide variety of applications:

  • Adjusting thermostats
  • Cooling solder
  • Setting hot melts
  • Cooling welding horns, machined or molded plastics, gas samples, etc.
Your choice of a system with a one outlet, or two outlet Cold Air Hose.

If you need a blast of cold air that can be precisely controlled, right at the source, look no further than the Adjustable Spot Cooler. If you have an application you’d like to discuss, give me a call.

Russ Bowman, CCASS

Application Engineer
Visit us on the Web
Follow me on Twitter
Like us on Facebook

EXAIR’s Cold Gun Promotion

It’s that time of year again for EXAIR‘s Cold Gun Promotion (online only). From November 1st 2024 through to the end of the year, you can receive a Dual Point Hose Kit for free with the purchase of our promotional Cold Gun System w/ Single Point Hose Kit or promotional High Power Cold Gun System w/ Single Point Hose Kit. These hose kits come with standard point tips or 1″ fan tips. The dual point kit gives you the ability to provide cooling to more than one side of large diameter cutters and components that need cooling.

Cold Guns Systems

So, what’s so great about EXAIR’s Cold Gun? If you’re looking for a way to extend the life of your tools by keeping them cool without the mess that can be left when using a coolant, then our Cold Gun is the perfect solution. When supplied with a source of compressed air, the Cold Gun and High Power Cold Gun produces a stream of clean, cold air that is 50°F below your compressed air supply temperature. In addition to this, the Cold Gun is very quiet at only 70dBA and has no moving parts to wear out. Just supply it with clean, dry compressed air, and it will run maintenance free for many years!

With a magnetic base, the Cold Gun is easy to install and mount. The Cold Gun is an ideal alternative to messy and expensive coolant mist systems. It eliminates the cost of purchase and disposal of cutting fluids as well as worker related health problems from breathing airborne coolant or slipping on wet floors. Replacing a coolant-based system also eliminates the need for secondary cleaning operations after milling or drilling.

If you would like to discuss how an EXAIR Cold Gun can help you with your coolant application, then give us a call!

Al Wooffitt
Application Engineer

Send me an Email
Find us on the Web
Like us on Facebook
Twitter: @EXAIR_AW

Controlling Temperature And Flow From A Vortex Tube

The Vortex Tube is among the most fascinating air-operated devices to me. It’s right up there with the pneumatic impact wrench, which is my HIGHLY preferred method of removing (and replacing) a tire on a vehicle. While there are several different types of impact wrenches, they all basically use air pressure to move internal parts in a manner in which they strike (or impact) a rotating element with a socket on the end, resulting in a lot more torque being applied than if it was simply spinning a propeller attached to the shaft.

Vortex Tubes, on the other hand, all work on the same principle, discovered by a French engineer, Georges Ranque, while he was experimenting with a new design of a vacuum pump in 1922. There doesn’t seem to be any record of him completing the work on his newfangled vacuum pump, but he did continue experimenting with this device that made hot air come out one end, and cold air come out the other, getting a patent for it in 1931.

How a Vortex Tube Works: compressed air enters the vortex spin chamber (big blue arrow from above left), where the Generator imparts a spinning motion to it (red ribbon, moving to the right). When the spinning air flow reaches the other end, some of it is forced to change direction and, while still spinning, flow the other way (blue ribbon, moving to the left). The rest exits through the hot valve (represented by the yellow cone). When the spinning air flow changes directions, it gives off energy in the form of heat, causing hot air to exit one way, and cold air to exit the other.

EXAIR offers two series of Vortex Tubes:

  • 32XX series, or Maximum Refrigeration. These make the highest flows of cold air, at temperatures suitable for rapid cooling of warm objects to ambient (or below) temperatures.
  • 34XX series, or Maximum Cold Temperature. These will give you the coldest air possible – as low as minus 50°F – but at lower flows, relative to the 32XX series. I’ll go into more detail on both of these in a minute.
Sub-zero air flow from Model 3408 Vortex Tubes cools & solidifies chocolate in candy molds.

Both of these series consist of Vortex Tubes in three sizes, with multiple models in each size. The difference between the models in each series is the compressed air consumption:

You can control the temperature, and the flows (both hot and cold), of any Vortex Tube in a few different ways:

  • Supply pressure affects the total flow of the two air streams, and the magnitude of the change in temperature. Since higher pressure equals more energy, it stands to reason that, at higher pressures, the hot air will be hotter, and the cold air will be colder.
  • Cold Fraction is the percentage of the compressed air supply that gets directed to the cold end. You can get VERY cold air from a Vortex Tube by setting it to a low cold fraction. This is done by opening the Hot Valve to let more hot air out. That causes the flow rate, and the temperature of the air coming out of the cold end, to drop.
Turning the Hot Valve counterclockwise (blue arrow) lets more hot air out, which lowers the cold air flow, and temperature. Turning it clockwise (red arrow) lets less hot air out, which raises the cold air flow…and temperature.
  • Two types of Generators can be installed in an EXAIR Vortex Tube – these are what determine the series I mentioned above:
    • Type “R” (Maximum Refrigeration) Generators allow for Cold Fraction adjustments from 50-80%. With an air supply pressure of 100psig, the cold air will be 54°F (when set to an 80% Cold Fraction) to 100°F (at a 50% Cold Fraction) lower than the compressed air supply temperature. This makes them suitable for applications where rapid cooling of an object is needed.
    • Type “C” (Maximum Cold Temperature) Generators give you Cold Fraction adjustments from 20-50%. A Vortex Tube with a “C” Generator installed will give you the same 100°F temperature drop as the “R” Generator will at a 50% Cold Fraction, but at a 20% Cold Fraction, it’ll be 123°F colder than the supply. These are used where cooling to temperatures below 0°F is needed.
How to tell which Generator is installed in a Vortex Tube.

If you need to remove & replace a tire, I strongly recommend using a pneumatic impact wrench. If you need to blow cold air for something, I just as strongly recommend using an EXAIR Vortex Tube. Different applications require different series, models, and settings. Give me a call if you’d like to find out which combination of those is right for your application.

Russ Bowman, CCASS

Application Engineer
Visit us on the Web
Follow me on Twitter
Like us on Facebook