Gen4 Static Eliminators Sove Static Problems for Printing Co.

When the weather gets dry and cool, static can be generated very easily, and it can become a real nuisance.  For the printing industry, static forces can pull or push the ink droplets which can create poor print quality like “ghost” images.  Static can also cause contamination to “stick” to the surface of the sheets affecting the printing process.  This can slow production, generate high scrap rates, and allow for poor quality.  In this blog, I will share the details about a printing company having static problems and a simple solution with a Gen4 Static Eliminator.

For this printing company, static was causing issues in print quality on their polypropylene sheets. Polypropylene is a non-conductive material which can generate high amounts of static that can cause many issues.  Their manual operation of moving, sliding, and picking up of the polypropylene sheets was generating the static.  Now that we found the cause, I had to determine a solution.

They sent pictures to describe the process in more detail.  An operator would pick up a sheet with the dimensions of 3 feet wide by 5 feet long (0.9 meters by 1.5 meters) from a bin.  He or she would load three polypropylene sheets onto a wide vacuum table next to the printing machine.  The table had an indicating bar which used yellow/green lights to align each sheet.  Once the indicator lights turned green, this meant that the sheet was aligned properly, and the operator would then hit a switch.

A dual rail with vacuum cups would come over and “grab” the three sheets.  The vacuum rail would pull the new sheets onto a sliding platform at the same time removing the printed sheets into a stacking area.  With the new sheets, this sliding platform would travel into the print machine where the print head would create the images.

Once the printing was completed, the sliding platform would come back to the original position where the process would repeat itself.  With all the handling and moving of the polypropylene sheets, static was being generated.  To improve their printing process by removing the static, we had to target an area where we would not have to worry about static regenerating.

EXAIR is a leading manufacturer of Static Eliminators, and we had a good discussion in solving his issue.  Ideally, we want to place the Static Eliminator just before the printing process.  In this application.  I recommended to them to locate a Gen4 Ionizing Bar just behind the indicating bar.  This would remove any static as the sheets were going onto the sliding platform.  Since the sheets were 3 feet (0.9 meters) wide, we needed to cover a span of 9 feet (2.7 meters) total.  Believe it or not, EXAIR manufactures and stocks an Ionizing Bar this long!!!

For this customer, they would not have to worry about any stop gaps in coverage with a single length product.  Also, the profile for the Gen4 Ionizing Bar is very thin and would not interfere with the vacuum rail system.  So, when the vacuum rail picks up the polypropylene sheets, the Gen4 Ionizing Bar will be able to remove the static from the printable surface.

Gen4 Ionizing Bar with 7960 Power Supply

I recommended the model 80108 Gen4 Ionizing Bar with the model 7960 Gen4 Power Supply.  This model can emit ions that can cover a span of 108 inches (2.73 meters).  The Gen4 Power Supply, which generates a 5,000 Volt signal, connects to the Gen4 Ionizing Bar with an electromagnetically shielded durable cable.  The alternating current generated by the Power Supply allows for the creation of both positive and negative ions from each point.  This will ensure neutralization of any type of static.

The Ionizing Bar can be positioned between 0.5” (13mm) to 2” (51mm) from the sheet surface to optimize decay rates.  After they mounted and started using the Ionization Bar, the static was removed quickly, and the printing issues were eliminated.  With a quick and simple set up of the Gen4 Ionizing Bar, they were able to get back on track with great quality and fast productivity.

If you have static issues with your printing process, you can contact an Application Engineer at EXAIR.  We will be happy to make your static issues disappear and your vibrant images reappear.

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

 

Video Blog: Cleaning Gen4 Ionizing Bars

EXAIR’s Gen4 Super Ion Air Knife and Ionizing Bars are a great way to relieve static charges in your products and/or processes.  They are a very powerful, efficient design that will eliminate static charges and require only minimal maintenance to keep them performing at peak efficiency.

Check out the video below to see just how easy it is!

When you are looking for expert advice on your static relief application or any of our safe, quiet and efficient point of use compressed air products give us a call.   We would enjoy hearing from you!

Steve Harrison
Application Engineer
Send me an email
Find us on the Web 
Follow me on Twitter
Like us on Facebook

EXAIR Displays Benefits of Ion Air Gun Static Eliminators

EXAIR manufactures a range of Static Eliminator products that are all efficient, effective, and easy to use…none more so than the Gen4 Ion Air Gun. Consider:

  • It’s “plug and play,” all the way.  Connect the cable to the Power Supply, and hook it up to your compressed air system, and you’re ready to go.
  • It’s efficient and quiet.  The high velocity jet entrains an enormous amount of air from the surrounding environment, where it’s ionized and ready to eliminate static charge quickly and effectively.
  • Instant static dissipation, at your fingertips (literally) – squeeze the trigger to blow ionized air, anywhere you want (well, within the reach of the 10 foot cable, anyway.)
Model 8493 Gen4 Ion Air Gun Kit comes with everything you need, right out of the box. Just add compressed air.

Again, the Gen4 Ion Air Gun is just one of our Static Eliminator products.  How do you know if it’s the right one?  The selection of many EXAIR Intelligent Compressed Air Products comes down to the size & shape of the air flow that will solve the application.  Static Eliminators are no different.

  • If you need to treat a large surface, you might be looking for a Gen4 Super Ion Air Knife.  They come in lengths from 3 inches to 9 feet long, and blow a laminar, even curtain of ionized air that’s extremely effective and fast at static elimination, even at very low supply pressures.
  • Gen4 Super Ion Air Wipes blow a 360° ionized airstream for pipes, cables, extruded shapes, etc.
  • Gen4 Ion Air Cannons and Gen4 Ion Air Jets are made to mount in place, and blow a focused, conical flow of ionized air.

If you’ve got large areas, multiple surfaces, or complex geometries to contend with, one (or an array) of these products might be the solution.  For a simple, straightforward, hand held static elimination solution, though, it just doesn’t get any easier than the EXAIR Gen4 Ion Air Gun.  Call me to find out how you can get one today.

***Order any qualifying EXAIR Static Eliminator by February 28, 2019, and we will include a FREE AC Sensor.  Click here for details.***

Russ Bowman
Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook

Gen4 Ion Air Cannon Static Eliminators Used in Tight Spaces

gen4-iacfillbotl_500xsq
Gen4 IAC removing static from the inside of plastic bottles

The lower relative humidity associated with the cold, dry air of winter results in a significant increase in calls related to static problems. Luckily, EXAIR has a wide-range of Static Eliminators that are designed specifically to address static issues in a variety of industries. Materials such as paper, plastic, or textiles will normally contain an equal number of both positive and negative ions. When subjected to friction, this balance can be disturbed if the atoms gain or lose an electron. This gaining/losing of an electron causes the atom to be electrically imbalanced.

The static charge will then exert a force on nearby charged objects or grounded conductors (including personnel). These issues can also manifest in the form of dust clinging to product, product clinging to itself, rollers, machine beds or frames, materials jamming, and sheet feeding problems. Our Gen4 Static Eliminators have undergone independent laboratory tests to certify that they meet the rigorous safety, health, and environmental standards of the USA, European Union and Canada that are required to attain the CE and UL marks.

One of these such products is the Gen4 Ion Air Cannon. EXAIR’s Gen4 Ion Air Cannon neutralizes static charges at distances up to 15 feet without any moving parts. Utilizing EXAIR’s 2” Super Air Amplifier, the Ion Air Cannon will maximize ionized airflow while minimizing compressed air consumption. The strong, concentrated, quiet, and efficient ionized air is capable of eliminating a 5kV charge in as little as .37 seconds.

iac_plasticsheets800sq
Ion Air Cannon removing static from in between plastic sheets

The compact design saves space and allows it to be mounted in confined areas on walls, machine frames, bench tops, etc. The stand is pre-drilled for easy mounting, and incorporates a swivel adjustment to precisely position the airflow. Some examples of applications that have required the assistance of an Ion Air Cannon include: removing static from motorcycle bodies prior to painting, static removal on PCB boards, and disposable diaper manufacturing.

With a wide variety of Static Eliminating products available from stock, don’t wait for your static problems to subside when humidity levels come back up in the spring. Get yourself a Gen4 Static Eliminator from EXAIR and make sure you’re able to operate, static-free, for the rest of this winter and in the subsequent seasons to come!

Tyler Daniel
Application Engineer
E-mail: TylerDaniel@exair.com