Industrial Safety: Compressed Air

We have a statement that says, “Safety is everyone’s responsibility.”  EXAIR builds its name around this by manufacturing safe and protective compressed air products.  In the United States, we have an organization called the Occupational Safety and Health Administration (OSHA) that enforces governmental directives for safe and healthy working environments.  They do training, outreach programs, and educational assistance for manufacturing plants to reduce injuries and fatalities.  They can also enforce these directives with heavy fines for violations.  With compressed air systems, the two most common violations are 29CFR 1910.242(b) for dead-end pressure/chip shielding and 29CFR 1910.95(a) for maximum allowable noise exposure.

Unsafe Nozzle

Here is an example of a nozzle that is dangerous.  As you can see, there is only one path where the air can pass through and be blocked.  Other similar types of blow-off devices that would fall into this same group would include copper tubes, flexible lines, and open pipes.  They are dangerous as compressed air cannot escape if it is blocked by your body or skin.  If operated above 30 PSIG (2 bar), these nozzles could penetrate the skin and create an air embolism within the body, which can cause bodily harm or death.  This is a hazard that can be avoided by using EXAIR Super Air Nozzles and Safety Air Guns.  The nozzles are designed with fins, which allow the air to escape and cannot be blocked by your skin.  So, you can use the EXAIR Super Air Nozzles safely above 30 PSIG (2 bar) and remain OSHA compliant.

Unsafe Air Gun

To counteract the dead-end pressure violation, some nozzle manufacturers create a hole through the side of the nozzle (reference photo above).  This will allow the compressed air to escape, but now the issue is noise level.  With an “open” hole in the nozzle, the compressed air is very turbulent and very loud.  The National Institute for Occupational Safety and Health (NIOSH) states that 70% to 80% of all hearing loss within a manufacturing plant is caused by compressed air.  OSHA created a chart to show the maximum allowable noise exposure.  This chart shows the exposure time and noise limits before hearing protection is required.  The EXAIR Super Air Nozzles, Super Air Knives, and Super Air Amplifiers are designed to have laminar flow, which makes them very quiet.  As an example, the model 1210 Safety Air Gun has a sound level of only 74 dBA, well under the noise exposure limit for 8 hours.

NIOSH created an overview of how to handle hazards in the workplace.  They call it the Hierarchy of Controls to best protect workers from danger.  The most effective way is by eliminating the hazard or by substituting the hazard.  The least effective way is with Personal Protective Equipment, or PPE.  For unsafe compressed air nozzles and guns, the proper way to reduce this hazard is to substitute it with an engineered solution.

One of the last things that companies think about when purchasing compressed air products is safety.  Loud noises and dead-end pressure can be missed or forgotten.  To avoid any future fines or having to purchase additional personal protective equipment (PPE), it will be less expensive and a preferred safety strategy to purchase EXAIR products.  As in the above Hazard Hierarchy of Controls chart, EXAIR products are that engineered solution.  If you would like to improve the safety of your facility and reduce energy costs, an Application Engineer at EXAIR can review your current blow-off devices.  Remember, safety is everyone’s responsibility. 

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

Picture:  Safety First by Succo.  Pixabay License

About OSHA 29 CFR 1910.242(b) for Compressed Air Safety

In February of 1972 OSHA released a standard to improve worker safety when operating handheld compressed air devices being used for cleaning purposes. This directive focuses around human skins permeability. That is, if you were to take an open ended pipe that had compressed air being discharged over 30 psig it can actually push through the skin and create an air embolism.

OSHA’s Directive 29 CFR 1910.242(b)

Air Embolisms are extremely painful, and in extreme cases, can be deadly. The risk associated with an air embolism can be mitigated by following the OSHA directive and reducing the downstream pressure of an air nozzle or nozzle pressure below 30 psi for all static conditions. Dead ending is when the passageway for the air becomes blocked and turns a dynamic flow of air into a static flow. This is in the event the pipe, nozzle, lance, etc. becomes blocked by a human’s body. This is a directive that all Intelligent Compressed Air® products from EXAIR focus on meeting or exceeding.

Our Air Nozzles and Jets video shows a great depiction of how this can be achieved with our engineered design of nozzles. The recessed holes and the fact that there are multiple passages for the air to exit are easy to see on the nozzle. Products like the Super Air Knife may not be so easy to see but the way the air knife cap overlaps prevents the Super Air Knife from being dead ended in the event an operator comes into contact with the discharge air.

Even though this directive was created in 1972 it continues to be at the forefront of industrial environments. I have even been to a custom artwork facility that was effected by this standard because they would use a handheld blowgun to remove dust and debris before matting and framing artwork with glass. They also removed dirt and dust from the frames before paint. This wasn’t your typical manufacturing environment yet they were still held to the same standards and were made safe by implementing engineered solutions such as our Super Air Nozzle.

If you would like to discuss how we can help increase your operator safety and ensure you meet or exceed OSHA 29 CFR 1910.242(b), please contact an Application Engineer today.

Brian Farno
Application Engineer
BrianFarno@EXAIR.com
@EXAIR_BF

1 – OSHA Instruction STD 01-13-001 – Retrieved from: https://www.osha.gov/enforcement/directives/std-01-13-001