EXAIR’s Flat Nozzles: Safe, Reliable, and Efficient

Here on the EXAIR Blog we frequently discuss dead-end pressure as explained in OSHA Standard 1910.242(b). This directive states that the when compressed air is used for cleaning purposes, the dead-ended pressure must not exceed 30 psig. When pressures greater than this occur, there is potential for an air embolism. This animation shows and explains how an air embolism can affect the body.

EXAIR’s Flat Nozzles adhere to this OSHA directive. The Flat Nozzles consist of three primary components: the body, the cap, and the shim. The thickness of the shim will dictate the flow and force through the nozzle and can be easily adjusted. The cap slightly protrudes from the body and shim, creating a gap when it is pressed up onto the skin. By ensuring that there is always an avenue for that air to escape, there is no potential for it to be dead-ended.

2fsanfam2
From top to bottom: Model 1126, 1126SS, 1122, and 1122SS

EXAIR’s flat nozzles are available in two sizes: 1” and 2”. Each size has a shim set that can be purchased for adjusting both the flow and force from the nozzle. These nozzles are available in both zinc/aluminum alloy as well as 316 grade Stainless Steel. They can be used by themselves, installed on our Safety Air Guns, or in conjunction with our Stay Set Hoses that allow for easy re-positioning.

You may have seen (or used) the plastic flat nozzles that come in a variety of different colors. EXAIR’s flat nozzle is a safe, efficient, and more robust replacement that will maintain a similar airflow pattern at a dramatically reduced operating cost. Where plastic nozzles may become damaged or break off, the rigid construction of EXAIR’s Flat Nozzle will not. In addition to be safe, durable, and reliable, EXAIR’s flat nozzles also offer a reduced sound level compared to these styles of nozzle. Reducing sound is another directive that OSHA 29 CFR 1910.95 covers. If you’re using an unsafe nozzle in your facility, OSHA can quickly begin assessing fines for each violation. They don’t announce their visits beforehand, so make sure you do your due diligence and assess your compressed air blowoff products yourself!

2san_blowaway
EXAIR 2″ Flat Super Air Nozzle “blows” away the competition!

If you would like to discuss how to make your compressed air use safer and more efficient, give us a call. Our team of highly-trained Application Engineers is standing by, ready to help you make the switch to an Intelligent Compressed Air Product.

Tyler Daniel
Application Engineer

E-mail:TylerDaniel@exair.com
Twitter:@EXAIR_TD

Award Winning Compressed Air Nozzle Saves Hundreds of Dollars Annually

awards2013_1126_400wide

 

EXAIR’s 1 Inch Flat Super Air Nozzle won the Gold Award for Compressed Air from Plant Engineering in 2014. We won the award for the immense savings that our customers reap by using this nozzle to replace open blow offs. While saving compressed air, we also reduce noise level and comply with an OSHA regulation 192.242(b).  Do not leave that blow off open. It is costing you everyday in dollars; it may cost you more in OSHA fines later, and it will cost your employees hearing later.

A 1/4″ copper tube can use 33 SCFM at 80 PSIG of inlet pressure. This homemade blow off will use 1,980 standard cubic feet per hour. Typical industrial compressed air cost $0.25 per 1,000 standard cubic feet.  That 1/4 copper tube is costing you $0.50 every hour to run. Each year, one 1/4″ copper tube costs $2,970*.

The 1 inch Flat Super Air Nozzle, model 1126, uses 10.5 SCFM or 22.5 SCFM less than 1/4″ Copper tube.  Saving your company 22.5 SCFM, is the same as saving $0.34 every hour or $2,025 every year.*  Saving 22.5 SCFM also, means that your compressor system doesn’t have to work as hard.  A 5 HP compressor will put out 20 SCFM, so replacing one 1/4″ Copper Tube with a model 1126 will save you from upgrading compressor system as your company expands.

Regardless of the $2,025 you just saved by replacing the homemade blow offs with engineered nozzle, it is also an industry best practice because it can lower the noise exposure for personnel and prevent any harm from dead end pressure.  OSHA standard 29 CFR – 1910.95(a) requires that if an employee is exposed to greater than 100 dBA for 2 hours, he or she needs to wear hearing protection.  A 1/4″ copper tube will easily exceed 100 dBA.  The model 1126 will lower the noise level to 77 decibel, 13 dBA lower than the OSHA requirements for an 8 hour day.

Finally, the 1″ Flat Super Air Nozzle cannot be dead ended, which protects your employees from serious injury. In the event, that a compressed air orifice is blocked with no means of escape, air may enter the bloodstream from an open cut or wound in the skin. Compressed air must be kept below 30 PSIG to eliminate this danger when using an open pipe, tube or many commercial air nozzles. With EXAIR nozzles, pressure to the nozzle  can remain at line pressure and produce the maximum velocity and force for a successful application.

*Assuming 24 hours a day and 250 working days

Dave Woerner
Application Engineer
Davewoerner@EXAIR.com
@EXAIR_DW