NEMA 4X Panel Cooling Challenges

Electronic components don’t like heat, which is kind of ironic, considering they generate so much heat by themselves. Heat causes them to malfunction, and prolonged exposure can shorten their lifespan, or even cause them to fail RIGHT NOW. In any case, it’s important to keep them cool.

The computer that sits on my desk has a little fan in the back. This circulates fairly clean air from our climate-controlled office through the inside, keeping everything working just like it should.

It’d be great if ALL electrical & electronic component enclosures were situated in such ideal environments. Many, though, are subject to HARSH conditions: dust, oil vapor, high humidity, water spray for sanitation, high temperatures, corrosive elements – just to name a few. And EXAIR has panel cooling solutions for ALL of them.

Today, dear reader, we’re going to look at that last one: corrosive elements in the environment. Some of the more popular places where we encounter these are:

  • Paper mills use chemicals that create harsh vapors. If you’ve ever been around a paper mill, you likely know the smell of methyl mercaptan. Whether you know the name or not, it’s the source of that trademark odor that permeates the air for MILES around paper mills, and it’s a byproduct of pulp processing that’s corrosive in wet or humid environments . . .like paper mills.
  • Wastewater treatment plants use highly corrosive chemicals to make clean water out of — let’s just say, not-so-clean water. And, the process releases hydrogen sulfide gas, which is HIGHLY corrosive.
  • Chemical plants: they make corrosive stuff ON PURPOSE. To be fair, those harsh chemicals are used in the production of just about everything in the modern world.
  • Electroplating facilities use some of the strongest acids and bases in their plating solutions, which release harsh & corrosive vapors.
  • Food processing facilities have to wash down entire rooms within their buildings, and some of the sanitizing agents they use create corrosive conditions.

You obviously can’t use fans (like my desktop computer in our clean office environment) for cooling control panels in these environments. Panel air conditioners have filters that can get dirty in a hurry, cooling coils that get fouled and corroded, and electric motors that burn out quicker in harsh environments. These environments are where Cabinet Cooler Systems make the most sense. With no moving parts to wear or electrical components to burn out, they’ll run darn near indefinitely, maintenance free, as long as they’re supplied with clean compressed air. And since 100% of the cold air they make comes from the compressed air supply, when they’re properly installed on a sealed panel, the only thing the components inside are ever exposed to is clean, cold, moisture-free air.

EXAIR NEMA 12 (oil tight, dust tight, indoor duty) and NEMA 4 (splash resistant, indoor/outdoor duty) Cabinet Coolers are made of lightweight and fairly corrosion-resistant aluminum. When harsh corrosive elements are present, though, our NEMA 4X (corrosion resistant, indoor/outdoor duty) Cabinet Coolers are made of type 303 Stainless Steel. When PARTICULARLY corrosive elements are present, we also offer them in type 316 Stainless Steel as well.

EXAIR NEMA 4X Cabinet Coolers are made of Stainless Steel for corrosion resistance in the harshest of conditions.

If you’ve got electric panels in a harsh environment, EXAIR has reliable, durable cooling solutions. If you’d like to find out more, give me a call.

Russ Bowman, CCASS

Application Engineer
Visit us on the Web
Follow me on Twitter
Like us on Facebook

Hazardous Location Cabinet Cooler Systems “Make Things Better”

In a previous arc in my career path, I worked on, and then built, and then sold industrial pumps, so I’ve been in my fair share of chemical plants. Did you ever wonder what all these places make? A decent number of them make what are called “intermediates”. These are compounds, solutions, & substances that aren’t found in stores, but go into almost all of the goods that ARE found in stores. One such company used to make commercials that explained it nicely:

I recently had the pleasure of assisting a caller from a company like this, who wanted to install three of our Hazardous Location Cabinet Cooler Systems in their facility. This particular company doesn’t make anything shown in the commercial above; they make intermediates for agricultural use (to paraphrase the commercial, “they don’t make fertilizer; they make fertilizer better”). As is the case in MANY chemical plants, a good portion of their real estate is classified as hazardous area (as defined by regulatory oversight agencies) AND subject to exposure to some fairly corrosive chemicals. Now, these places all go to great lengths to ensure safety for personnel AND equipment, through compliance AND design. So, when they needed to add durable & reliable heat protection to their electrical panels, they called EXAIR.

This was a pretty easy application, as the engineer I spoke to had gotten the internal heat loads from the equipment supplier, and already knew that 316SS construction was needed for the corrosive elements the equipment could be exposed to. The panel was in a Class I Div 2 area (flammable gasses or vapors may be present in the event of an accident or during unusual operating conditions). After calculating the external heat load, we specified a Model HZ4725SS-316 NEMA 4X (316SS Construction) Hazardous Location Cabinet Cooler System, rated for 1,700 Btu/hr, and Model 902021 24VDC HazLoc Solenoid Valve. These panels came equipped with temperature monitors that they could wire our valves into, otherwise we’d have supplied Thermostat Controlled systems.

EXAIR HazLoc Cabinet Cooler Systems are rated for Class I Div 1 & 2, Class II Div 1 & 2, and Class III environments.

EXAIR Cabinet Cooler Systems are available, from stock, to suit most any electric/electronic panel heat protection need:

  • Cooling capacities from 275 to 5,600 Btu/hr. Call me if your heat load is outside this range…we can look at customized solutions too.
  • NEMA 12 (IP54), 4, or 4X (IP66) ratings.
  • Thermostat Control – Standard, or Electronic Temperature Control.
  • Non-Hazardous Purge for contaminant exclusion on less-than-ideally sealed enclosures.
  • High Temperature models for ambient temperatures from 125°F (52°C) to 200°F (93°C).
  • Side Mount Kits when space is limited above the panel.
  • 316SS construction for particularly aggressive environments.
  • UL Classified for hazardous locations, just like the one I wrote about above.

If you’d like to find out how easy it is to provide durable and reliable heat protection for your electrical panels, give me a call.

Russ Bowman, CCASS

Application Engineer
EXAIR Corporation