Measuring and Adding Sounds

My colleague, Russ Bowman, wrote a blog about “Sound Power vs Sound Pressure vs Sound Pressure Level”.  He discussed the logarithmic equations around sound.  I will be discussing what happens when you have more than one sound source, as often heard within manufacturing plants.  Sounds can be added together to determine the overall sound level that you hear.  This is very important when it comes to minimizing hearing loss.

In looking at a single source of sound, sound pressure is created by the loudness of a noise.  The units are measured in Pascals.  The lowest pressure perceived by human hearing is 0.00002 Pa, and we can use this value as a reference point.  From sound pressures, we can arrive at a sound pressure level which is measured in decibel, dB.  This correlation between sound pressures and sound pressure levels are calculated by Equation 1:

L = 20 * Log10 (P / Pref)

L – Sound Pressure Level, dB

P – Sound pressure, Pa

Pref – reference sound pressure, 0.00002 Pa

As an example, the sound pressure from a passenger car as heard from the roadside is 0.1 Pa.  With Equation 1, we can get the following decibel level:

L = 20 * Log10 (0.1Pa/0.00002Pa) = 74 dB

Because human ears are sensitive to different frequencies, the sound pressure levels can be modified, or weighted, to indicate an effective loudness level for humans.  This adjustment is done in two different ways; A-weighting and C-weighting.  The C-weighting is for very loud noises with high peaks or sharp impacts like gunfire. The A-weighting is the most used value as the sound pressure levels are adjusted by the frequency level.  For higher and lower frequencies, the change in the sound value is much greater than the mid-level frequencies that are within our hearing range.  Sound measurements for safety are measured on an A-weighted scale.  OSHA created a chart in the standard 29CFR-1910.95(a).  It shows the noise levels over exposure times for an operator.  To use the OSHA chart accurately, the total noise level in dBA should be calculated.

Hearing loss is the best known, but not the only, ill effect of harmful noise exposure. It can also cause physical and psychological stress, impair concentration, and contribute to workplace accidents or injuries.

To determine the total sound level, we can add all the sound pressure levels together by Equation 2:

Equation 2:

Where L1, L2… represents the sound pressure level in dBA for each sound source.

As an example, a manufacturing plant had an operator using a machine that had four copper tubes to blow off a cutting operation (reference photo below).

Blow off station

The decibel level for a copper tube was measured at 98 dBA.  The total amount of sound that the operator was exposed to was determined by Equation 2 with four values.

L = 10 * log10 (109.8 + 109.8 + 109.8 + 109.8)

L = 104 dBA

In looking at the OSHA chart above, the operator would only be allowed to operate the machine only a little over one hour without hearing protection.  In this same example, we replaced the copper tubes with an EXAIR Super Air Nozzle, model 1100SS.  The noise level for each nozzle is 74 dBA at 80 PSIG (5.5 bar).  By replacing all four copper tubes with Super Air Nozzles, Equation 2 becomes:

L = 10 * log10 (107.4 + 107.4+ 107.4 + 107.4)

L = 80 dBA

The total sound level is now in accordance with OSHA regulations for the operator to work all 8 hours at the machine without hearing protection.

A commonly used acronym for hearing safety is NIHL, or Noise Induced Hearing Loss.  To keep your operators safe and reduce NIHL, it is important to measure the total sound level in that area.  As a protocol in safety, it is a requirement to use engineering standards before purchasing personal protective equipment or PPE.  For the customer above, they followed that protocol with our Super Air Nozzles.  If you need to reduce noise levels in your facility, EXAIR offers a large line of blow-off products that can meet the safety requirements.  You can contact an Application Engineer for more information. 

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

Photo: Ear by PublicDomainPictures  Pixabay License

Limiting Noise Exposure with Mufflers for Compressed Air

Mufflers come in many shapes and sizes. Each with their own benefits.

If you have ever walked into a manufacturing facility and heard the hiss or even worse the banshee scream of compressed air being exhausted to ambient, whether it be from a cylinder discharge, a timed drain going off, or a bypass valve being activated, they all could be hushed with a muffler. A muffler for compressed air comes in several shapes and sizes. EXAIR offers four separate types from stock to help attenuate the noise disruption within your facility.

The OSHA standard for allowable noise exposure is 29 CFR-1910.95(a) and outlines the number of hours per day any individual can be exposed to a particular noise level. These noise levels are expressed in decibels (dbA).

Hearing loss is the best known, but not the only, ill effect of harmful noise exposure. It can also cause physical and psychological stress, impair concentration, and contribute to workplace accidents or injuries.
Reclassifying Mufflers attenuating the exhaust of a pneumatic cylinder.

The first type I would like to showcase are the Reclassifying Mufflers. These are ideal for cylinder exhausts or valves which commonly contain an oil mist within the air stream which can easily contaminate the surrounding area. The patented design of the removable element separates oil from the exhausted air so virtually no atomized oil is released into the environment. They also attenuate the exhaust noise level up to 35 decibels. The filter element helps the exhaust to meet the OSHA Standard 29 CFR 1910.1000, a worker’s cumulative exposure to oil mist must not exceed 5 mg/m³ by volume in any eight hour shift of a forty hour work week.

The chart below helps to properly size the Reclassifying Muffler for a pneumatic cylinder. One key to proper installation of these mufflers is they must be installed vertically in order to properly trap and drain the oil.

Reclassifying Muffler Quick Pick Chart
Sintered Bronze mufflers are excellent choices for tight installation locations and are easily sized.

The next type of muffler to discuss are the Sintered Bronze Mufflers that are offered in ten different sizes. These are an excellent low cost solution which easily install into new or existing ports. Each size is designed to provide minimal back pressure and restriction for the individual port size. The quick pick chart below helps to easily select the correct size for attenuating the exhaust of a pneumatic cylinder. One key difference between these and the Reclassifying Mufflers is, these do not have to be oriented vertically as they do not collect the oil out of the exhaust air.

undefined

The model 3913 – 3/4″ NPT Straight Through Muffler

If the process air needs to be directed or plumbed away from the operator then the Straight Through Mufflers are the ideal selection as they offer an NPT threaded inlet and exhaust. They are available in three standard NPT sizes from stock. These mufflers can be installed in any orientation and work well with our Vortex Tubes to help pass the cold air through while lowering the operating sound level of the tube. The average noise reduction of the Straight-Through Mufflers is 20 dB. This can easily reduce the noise level of an operation to below the OSHA standard requiring hearing protection for operators in the area.

The model 3903 Heavy Duty Muffler

The final option for mufflers from EXAIR are the Heavy Duty Mufflers. These are available in two sizes from stock and are constructed of corrosion-resistant aluminum with a stainless steel internal screen. These can be installed in any orientation and are ideal for protecting exhaust ports from contaminants that may clog or damage the device they are attached to. The typical noise reduction from installation is 14 dB with these mufflers.

These are available in two sizes from stock and are constructed of corrosion-resistant aluminum with a stainless steel internal screen. These can be installed in any orientation and are ideal for protecting exhaust ports from contaminants that may clog or damage the device they are attached to. The typical noise reduction from installation is 14 dB with these mufflers.

To summarize, EXAIR offers a multitude of options when it comes to lowering sound levels in operation areas that are caused by exhausted compressed air. Each of the mufflers discussed above are shipped same day from stock to meet your immediate need. If you are unsure of which muffler to use for your application, feel free to contact an Application Engineer.

Brian Farno
Application Engineer
Ph. 1-513-671-3322
BrianFarno@EXAIR.com
@EXAIR_BF

Brian Farno
Application Engineer
BrianFarno@EXAIR.com
@EXAIR_BF