EXAIR Digital Flowmeters With Wireless Capability

“You can’t manage what you don’t measure” is a well-known axiom in engineering & process improvement circles.  We talk to callers every day who are keen on conserving compressed air use in their facilities by making a few tweaks, considering a complete overhaul, or more often, some point in between.  Bottom line (literally) is, compressed air isn’t cheap, so small gains in efficiency can add up.  And large gains can be complete game-changers…following our Six Steps To Optimizing Your Compressed Air System has resulted in users being able to shut down 50 and 100 HP air compressors, saving thousands of dollar A MONTH in operating costs.

Step #1 is measurement, and that’s where the EXAIR Digital Flowmeter comes in.  They’re easy to install, highly accurate, extremely reliable, and available for just about any size pipe used for compressed air distribution.  They can output a 4-20mA signal straight from their PCB board, or serial comms (RS485) through an optional control board.  USB Data Loggers and Summing Remote Displays have proven to be value-added accessories for data management as well.

Summing Remote Display (left) for remote indication and totalizing data. USB Data Logger takes data from the Digital Flowmeter to your computer and outputs to its own software (shown above) or Microsoft Excel.

If you want to go wireless, we can do that too: using ZigBee mesh network protocol, a radio module is installed in the Digital Flowmeter with wireless gateway to transmit data to an Ethernet connected gateway.  The transmitting range is 100 ft (30 meters,) and the data can be passed from one radio module to another, allowing for multiple Digital Flowmeter installations to extend the distance over which they can communicate with the computer you’re using for central monitoring.  Advantages include:

  • Wireless monitoring of EXAIR Digital Flowmeters throughout your plant.
  • Prevents unwanted joining upon the network.
  • Monitoring software is included at no extra charge.
  • Measures & transmits both current air usage, and cumulative air usage data.
  • 128 bit encryption for wireless transmissions.
  • Comes configured & programmed, out of the box, available for installation on 1/2″ to 4″ SCH40 iron pipe, or 3/4″ to 4″ Type L copper pipe.
Digital Flowmeter w/ Wireless Capability, Gateway, and Drill Guide Kit

If you’d like to find out more about how easy it is to measure, manage, and optimize your compressed air usage, give me a call.

Russ Bowman
Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook

Proper Air Supply Line Size Equals Proper Performance

Pipe_460top
Properly sized piping will allow your compressed air operated equipment to operate efficiently!

On any given day myself and my Application Engineering Brethren here at EXAIR have discussions with customers on air starvation of any given EXAIR Product.  The calls generally start off the same, “The Line Vac is not performing like it should”.  We at EXAIR absolutely want to help you get the most out of our products and we certainly want them to perform to your expectation.  However they must be supplied with clean/dry compressed air at sufficient pressure and volume.

Just the other day I was discussing a performance issue with a customer on a 1″ Line Vac.  The customer thought he needed a larger Line Vac.  I asked the questions regarding the diameter of his Supply Line and if he was using Quick Connect or Push Lock connectors.  He was attempting to feed this Line Vac with 1/4″ Poly Tubing through a elbow Push to Loc fitting.

This 1″ Line Vac was being severely starved for air and therefore not performing as expected.  The 1″ Line Vac require’s 14.7 SCFM @ 80PSI to reach the rated performance of 42″ of water column.

Below is a table for Pipe/Hose sizing from the Line Vac installation manual that you can use as a reference guide.  It is recommended that if using hose for the supply air to go up to the next size over the pipe recommendation.

Chart2

Don’t forget that quick connects and Push Lock fittings are not recommended and could restrict the air flow which will have a negative impact on performance.

If you would like to discuss Line Vacs or any EXAIR product,  I would enjoy hearing from you…give me a call.

Steve Harrison
Application Engineer
Send me an email
Find us on the Web 
Follow me on Twitter
Like us on Facebook

CFM, ICFM, ACFM, SCFM: Why so many volumetric flow rates?

Air Compressor

Flow rate is the quantity of material that is moved per unit of time.  Generally, the quantity of material can be expressed as a mass or a volume.  For example, mass flow rates are in units of pounds per minute or kilograms per hour.  Volumetric flow rates are stated in cubic feet per minute or liters per hour.  The trick begins when volumetric flow rates are used for a compressible gas.  In this blog, I will go over the various acronyms and the reasons behind them.

What acronyms will be covered?

CFM – Cubic Feet per Minute

SCFM – Standard Cubic Feet per Minute

ACFM – Actual Cubic Feet per Minute

ICFM – Inlet Cubic Feet per Minute

The volumetric component of the flow rate is CFM or Cubic Feet per Minute.  This term is commonly used for rating air compressors.  From history of air compressors, they could calculate the volume of air being drawn into the air compressor by the size of cylinder.  With the volume of the compression chamber and the rotations per minute of the motor, RPM, they could calculate the volumetric air flows.  As conditions change like altitude, temperature, and relative humidity, the value of CFM changes.  To better clarify these conditions, compressor manufacturers decided to add terms with definition.  (For your information, air compressors still use CFM as a unit of air flow, but now this is defined at standard temperature and pressure).

The first letter in front of CFM above now defines the conditions in which the volumetric air flow is being measured.  This is important for comparing pneumatic components or for properly sizing pneumatic systems. Volume is measured with three areas: temperature, pressure, and relative humidity.  We can see this in the Ideal Gas Law: P * V = n * R * T or Equation 1:

V = n * R * T / P

V – Volume

n – Number of molecules of gas

R – Universal Gas Constant

T – Absolute Temperature

P – Absolute Pressure

The volume of air can change in reference to pressure, temperature, and the number of molecules.  Where is the relative humidity?  This would be referenced in the “n” term.  The more water vapor, or higher RH value, the less molecules of air is in a given volume.

SCFM is the most commonly used term, and it can be the most confusing.  The idea of this volumetric air flow is to set a reference point for comparisons.  So, no matter the pressure, temperature, or relative humidity, the volumetric air flows can be compared to each other at that reference point.  There have been many debates about an appropriate standard temperature and pressure, or STP.  But as long as you use the same reference point, then you can still compare the results.  In this blog, I will be using the Compressed Air and Gas Institute, CAGI, reference where the “Standard” condition is at 14.5 PSIA, 68 deg. F, and 0% RH.  Since we have a reference point, we still need to know the actual conditions for comparison.  It is like having a location of a restaurant as a reference, but if you do not know your current location, you cannot reach it.   Similarly, we are “moving” the air from its actual condition to a reference or “Standard” condition.  We will need to know where the air began in order to reach that reference point.  We will talk more about this later in this blog.

ACFM is the volumetric air flow under actual conditions.  This is actually the “true” flow rate.  Even though this term is hardly used, there are reasons why we will need to know this value.  We can size an air compressor that is not at “Standard” conditions, and we can use this value to calculate velocity and pressure drop in a system.  We can correlate between SCFM and ACFM with Equation 2:

ACFM = SCFM * [Pstd / (Pact – Psat Φ)] * (Tact / Tstd)

Where:

ACFM = Actual Cubic Feet per Minute
SCFM = Standard Cubic Feet per Minute
Pstd = standard absolute air pressure (psia)
Pact = absolute pressure at the actual level (psia)
Psat = saturation pressure at the actual temperature (psi)
Φ = Actual relative humidity
Tact = Actual ambient air temperature (oR)
Tstd = Standard temperature (oR)

ICFM is one of the newest terms in the history of air compressors.  This is where devices are added to the inlet of an air compressor, affecting the flow conditions.  If you have a blower on the inlet of an air compressor, the volumetric flow rate changes as the pressure and temperature rises at the “Inlet”.  If a filter is used, then the pressure drop will decrease the incoming pressure at the “Inlet”.  These devices that affect the volumetric flow rate for an air compressor should be considered.  The equation to relate the ACFM to ICFM is with Equation 3:

ICFM = ACFM * (Pact / Pf) * (Tf / Tact)

Where:

ICFM = Inlet Cubic Feet Per Minute

Pf  = Pressure after filter or inlet equipment (PSIA)

Tf = Temperature after filter or inlet equipment (°R)

Examples of these different types of flow rates can be found here in this EXAIR blog by Tyler Daniel.

To expand on my explanation above about SCFM and ACFM, a technical question comes up about the pressure when using SCFM.  The reference point of 14.5 PSIA is in the definition of SCFM.  Remember, this is only a reference point.  The starting location is actually required.  This would be the ACFM value where the air values are true and actual.  As an example, two air nozzles are rated for 60 SCFM.  An EXAIR Super Air Nozzle, model 1106, is cataloged at 80 PSIG, and a competitor is cataloged at 60 PSIG.  By comparison, they look like they use the same amount of compressed air, but actually they do not.  To simplify Equation 2, we can compare the two nozzles at the same temperature and RH at 68 Deg. F and 0% RH respectively.  This equation can be reduced to Equation 4:

ACFM = SCFM * 14.5 / (P + 14.5)

@60 PSIG Competitor:

ACFM = 60 SCFM * 14.5 PSIA/ (60 PSIG + 14.5 PSIA)

= 11.7 ACFM

@80 PSIG EXAIR Super Air Nozzle:

ACFM = 60 SCFM * 14.5 PSIA / (80 PSIG + 14.5PSIA)

= 9.2 ACFM

Even though the SCFM is the same amount, you are actually using 21% more air with the competitive nozzle that was reported at 60 PSIG.  So, when it comes to rating compressed air products or air compressors, always ask the conditions of pressure, temperature and RH.  The more you know about volumetric flow rates, the better decision that you can make.  If you need help, you can always contact our application engineers at EXAIR.

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

 

Advantages of Thermal Mass or Thermal Dispersion Flow Measurement

EXAIR’s Digital Flow Meter offers an easy way to measure, monitor and record compressed air consumption. The Digital display shows the current amount of compressed air flow, allowing for tracking to identify costly leaks and/or inefficient air users.

dfm

How exactly does the Digital Flow Meter work?  The unit falls under the category of Thermal Mass or Thermal Dispersion type flow meters.  Below shows the backside of a unit.

IMG_7387

Thermal mass flow meters have the advantage of using a simple method of measuring flow without causing a significant pressure drop. The EXAIR units have (2) probes that are inserted through the pipe wall and into the air flow.  Each of the probes has a resistance temperature detector (RTD.) One of the probes measures the temperature of the air flow.  The other probe is heated to maintain a preset temperature difference from the temperature measured by the first probe.  The faster the air flow, the more heat that is required to keep the second probe at the prescribed temperature.  From Heat Transfer principles, the heat energy input required to maintain the preset temperature is based on the mass velocity of the air.  Using basic physical properties for compressed air, the volumetric rate can be determined (SCFM), and displayed.

It is important to note that the compressed air should be filtered to remove oils, and dried to remove water, as these liquids have different physical properties from air, and will cause erroneous readings.

Advantages

  • Easy to install – No cutting or welding required
  • Summing Remote Display and Data Logger available
  • Sensitive at low flows
  • Rugged, reliable and no moving parts
  • No calibration or set-up required
  • Models from 1/2″ to 4″ schedule 40 iron pipe in stock
  • Short lead time for sizes up to 6″ Schedule 40 iron pipe
  • Available for size 3/4″ to 4″ copper pipe
  • New Wireless Capability