Intelligent Compressed Air: What You Need To Know About Deliquescent Dryers

Moisture free air is a “must” for industrial use, for a number of reasons:

  • An awful lot of distribution systems incorporate iron pipe. It’s inexpensive, readily available, easy to work with, rated for pressure, and has a long history of successful installations. Iron pipe will also oxidize (make rust) in the presence of water:
Here’s what we find a lot of the time inside a Reversible Drum Vac that’s been sent in for refurbishment because it’s not drawing effective vacuum anymore.
  • Regardless of what your distribution lines and components are made of, water droplets can erode them. Compressed air itself is a gas; it follows the curves in elbows, and flows around valve discs & regulator diaphragms. Water droplets, on the other hand, run full speed INTO those things, often at high velocity. This eventually causes pitting, which is bad enough…those pits, though, are little pockets for salts, acids, or alkalines to effect their destructive little chemical reactions.
  • When used for blow off applications, anything in your compressed air will get on anything you’re blowing off. If the intent is to remove moisture from a surface, moisture in your compressed air supply decidedly works against your goal.
  • Water can freeze as it is carried along with air flow through orifices. This can quickly block the flow of air. The US Navy lost a submarine, USS Thresher (SSN-593) and all hands in 1963. A number of factors contributed to the sinking, but a significant one was that compressed air being blown into the ballast tanks (to create negative buoyancy) had higher than permissible moisture content, and froze in orifice plates in the lines. The ballast tanks stayed full of water, and 129 sailors & shipyard personnel died as the boat passed crush depth.

There are a number of types of air dryers that are commonly fitted to industrial air compressors to take care of moisture problems. The least expensive one of these is the Single Tower Deliquescent Dryer. Here’s how they work:

Deliquescent dryer: how it works (1)
  • Incoming compressed air enters near the base, where a form of mechanical separation occurs…the air flows back & forth, around trays of desiccant.  The simple act of changing direction causes some of the water to just fall out and collect in the bottom.
  • The air then flows upwards through the desiccant bed. The desiccant in a deliquescent dryer absorbs moisture (as opposed to the adsorption that occurs in a regenerative desiccant dryer) until they get so wet, they dissolve.
  • After the desiccant does its job, moisture free air flows out the top, and gets on with it’s work.

In addition to the low price tag, other things to like about them are:

  • Low pressure drop.
  • No moving parts or electrical components.
  • Can be used outdoors, and in hazardous, mobile, dirty, or corrosive environments.

Of course, there are things to NOT like about them as well:

  • Limited suppression of dew point – because they are drying the air to a specific relative humidity, as opposed to a specific dew point, the attainable dew point is dependent on the incoming air temperature, the chemical composition of the desiccant salt, and the ambient temperature where it’s installed. Unless you use some sort of specialty salt desiccant, the typical dew point is only 20-25ºF lower than the air inlet temperature.
  • Desiccant carryover – speaking of those specialty salts, they’re even more corrosive than the basic sodium chloride that’s often used. Any carryover will wreak havoc on your distribution system and air operated devices.

Deliquescent dryers’ particular set of “pros and cons” presents challenges for their use in industrial settings, for sure. But if the primary concern is preventing pipes from freezing up, then their low cost, low maintenance, and simplicity make them a great choice.

At EXAIR Corporation, we’re keen on compressed air efficiency. The attention to detail we pay to our products – from design, to manufacturing & assembly, to availability, and right on through to technical support – bears out our commitment to helping you get the most out of your compressed air system. If you’ve got questions, we can talk about this all day long…and most of the time, we do. Give me a call.

Russ Bowman, CCASS

Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook

Image courtesy of Brian S. Elliott, Wikimedia Commons Creative Commons Attribution-Share Alike 4.0 International License

Intelligent Compressed Air: Compressed Air System Components

In any manufacturing environment, compressed air is critical to the operation of many processes. You will often hear compressed air referred to as a “4th utility” in a manufacturing environment. The makeup of a compressed air system is usually divided into two primary parts: the supply side and the demand side. The supply side consists of components before and including the pressure/flow controller. The demand side then consists of all the components after the pressure/flow controller.

The first primary component in the system is the air compressor itself. There are two main categories of air compressors: positive-displacement and dynamic. In a positive-displacement type, a given quantity of air is trapped in a compression chamber. The volume of which it occupies is mechanically reduced (squished), causing a corresponding rise in pressure. In a dynamic compressor, velocity energy is imparted to continuously flowing air by a means of impellers rotating at a very high speed. The velocity energy is then converted into pressure energy.

Still on the supply side, but installed after the compressor, are aftercoolers, and compressed air dryers. An aftercooler is designed to cool the air down upon exiting from the compressor. During the compression, heat is generated that carries into the air supply. An aftercooler uses a fan to blow ambient air across coils to lower the compressed air temperature.

When air leaves the aftercooler, it is typically saturated since atmospheric air contains moisture. In higher temperatures, the air is capable of holding even more moisture. When this air is then cooled, it can no longer contain all of that moisture and is lost as condensation. The temperature at which the moisture can no longer be held is referred to as the dewpoint. Dryers are installed in the system to remove unwanted moisture from the air supply. Types of dryers available include: refrigerant dryers, desiccant dryers, and membrane dryers.

Also downstream of the compressor are filters used to remove particulate, condensate, and lubricant. Desiccant and deliquescent-type dryers require a pre-filter to protect the drying media from contamination that can quickly render it useless. A refrigerant-type dryer may not require a filter before/after, but any processes or components downstream can be impacted by contaminants in the compressed air system.

Moving on to the demand side, we have the distribution system made up of a network of compressed air piping, receiver tanks when necessary, and point of use filters/regulators. Compressed air piping is commonly available as schedule 40 steel pipe, copper pipe, and aluminum pipe. Some composite plastics are available as well, however PVC should NEVER be used for compressed air as some lubricants present in the air can act as a solvent and degrade the pipe over time.

Receiver tanks are installed in the distribution system to provide a source of compressed air close to the point of use, rather than relying on the output of the compressor. The receiver tank acts as a “battery” for the system, storing compressed air energy to be used in periods of peak demand. This helps to maintain a stable compressed air pressure. It improves the overall performance of the system and helps to prevent pressure drop.

Finally, we move on to the point-of-use. While particulate and oil removal filters may be installed at the compressor output, it is still often required to install secondary filtration immediately at the point-of-use to remove any residual debris, particulate, and oil. Receiver tanks and old piping are both notorious for delivering contaminants downstream, after the initial filters.

Regulator and filter

In any application necessitating the use of compressed air, pressure should be controlled to minimize the air consumption at the point of use. Pressure regulators are available to control the air pressure within the system and throttle the appropriate supply of air to any pneumatic device. While one advantage of a pressure regulator is certainly maintaining consistent pressure to your compressed air devices, using them to minimize your pressure can result in dramatic savings to your costs of compressed air. As pressure and flow are directly related, lowering the pressure supplied results in less compressed air usage.

EXAIR manufactures a wide variety of products utilizing this compressed air to help you with your process problems. If you’d like to discuss your compressed air system, or have an application that necessitates an Intelligent Compressed Air Product, give us a call.

Tyler Daniel
Application Engineer
E-mail: TylerDaniel@EXAIR.com
Twitter: @EXAIR_TD

Compressor Image courtesy of Compressor1 via Creative Commons License

Compressed Air Supply Side: What Is A Deliquescent Dryer, And When Would You Use One?

As we head in to the colder months here in Ohio, I will soon be getting my humidifier out of the basement and set up in my bedroom. The dry air that accompanies the onset of winter chaps my lips, cracks the skin on my knuckles, affects my nasal passages, and oftentimes makes me wake up with a sore throat…something I definitely don’t want to happen in the middle of a pandemic! So I put some water vapor in my home’s air, on purpose, to take care of all of that.

Moisture in an industrial compressed air system, however, isn’t good for anything.  It’ll corrode your pipes, get rust in your pneumatic tools, motors, and cylinders, and spit out of your blow off devices, all over whatever you’re using your air to blow off.  Depending on the type of compressor, where, and how, it’s used, there are different types of dryers.  Today, dear reader, we’re taking a look at one of the most basic moisture removal systems: the deliquescent dryer.  The principle of operation is as follows:

  • Deliquescent dryer: how it works (1)
    Incoming compressed air enters near the base, where a form of mechanical separation occurs…the air flows back & forth, around trays of desiccant.  The simple act of changing direction causes a certain amount of free liquid to just fall out and collect in the bottom.
  • The air then flows upwards through the desiccant bed. The desiccant in a deliquescent dryer absorbs moisture (as opposed to the adsorption that occurs in a regenerative desiccant dryer) until they get so wet, they dissolve.
  • The desiccant level has to be monitored (commonly via a sight glass) so it can be replaced as it’s consumed.
  • After the desiccant does its job, moisture free air flows out the top, and gets on with it’s work.

Deliquescent dryers, owing to their simplicity, are the least expensive air dryers.  They have no moving parts and no electricity, so the only maintenance involved is replacing the desiccant media as it’s consumed.  This makes them especially popular in mobile/on-site applications involving portable or tow-behind, engine driven compressors, since they don’t need power to run.

There are several disadvantages, also owing to their simplicity:

  • The deliquescent media has to be periodically replenished.  If you don’t stay on top of it, you can find yourself shut down while you go back to the shop to get a big bag of salt.  That’s time your boss can’t charge your customer for.  Also, the cost of the new media is a continual operating cost of the dryer…something you don’t have to account for with the regenerative desiccant models.
  • Disposal of the waste media can be a concern…you definitely want to check your local environmental regulations before dumping it in the garbage.  Your boss won’t like talking to the EPA about THAT either.
  • They have to be equipped with a particulate filter on the discharge to keep the deliquescent media (which, being a salt, is corrosive in nature) from entering your system.  That would be even worse than water moisture…which this is there to prevent in the first place.
  • They don’t get near as low of a dewpoint as other dryers – the best you can hope for is 20°F to 30°F.  Which is fine, given the above mentioned nature of applications where these are commonly used.  You just wouldn’t want to use them to supply a product like an EXAIR Vortex Tube…which can turn that in to -40°F cold air, causing the water vapor to turn to liquid, and then to ice.  In a hurry.

EXAIR Corporation is in the business of helping you get the most out of your compressed air.  If you want to learn more, please follow our blog.  If you have specific questions, give me a call.

Russ Bowman
Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook

 

(1) – Deliquescent Dryer Image: VMAC Air Innovated: The Deliquescent Dryer – https://www.vmacair.com/blog/the-deliquescent-dryer/

Compressed Air Membrane Dryers: What are They? How do They Work?

A critical component on the supply side of your compressor system is the dryer. Atmospheric air contained within a compressed air system contains water vapor. The higher the temperature of the air, the more volume of moisture that air is capable of holding. As air is cooled, this water vapor can no longer be contained and this water falls out in the form of condensation. The temperature where this water will drop out is referred to as the dew point.

At a temperature of 75°F and 75% relative humidity, approximately 20 gallons of water will enter a 25HP compressor during a 24-hour period. As air is compressed, this water becomes concentrated. Since it’s heated during the compression process, this water stays in a vapor form. When this air cools further downstream, this vapor condenses into droplet form.

Moisture within the compressed air system can result in rust forming on the inside of the distribution piping, process failure due to clogged frozen lines in colder weather, false readings from instruments and controls, as well as issues with the point of use products installed within the system.

The solution to this problem is to install a dryer system. We’ve spent some time here on the EXAIR blog reviewing refrigerant dryers , desiccant dryersdeliquescent dryers, and heat of compression dryers. For the purposes of this blog, I’m going to focus on one of the newer styles on the market today: the membrane dryer.

Membrane Dryer

In a membrane dryer, compressed air is forced through a specially designed membrane that permits water vapor to pass through faster than the air. The water vapor is then purged along with a small amount of air while the rest of the compressed air passes through downstream. Generally, the dew point after the membrane dryer is reduced to about 40°F with even lower dew points also possible down to as low as -40°F!

With such low dew points possible, it makes a membrane dryer an optimal choice in outdoor applications that are susceptible to frost in colder climates. Membrane dryers also are able to be used in medical and dental applications where consistent reliability is critical.

A membrane dryer does not require a source of electricity in order to operate. The compact size makes it simple to install without requiring a lot of downtime and floor space. Since they have no moving parts, maintenance needed is minimal. Most often, this maintenance takes the form of checking/replacing filter elements just upstream of the membrane dryer. The membrane itself does need to be periodically replaced, an indicator on the membrane dryer will display when it needs to be changed. If particular instruments or processes in your facility are sensitive to moisture, a membrane dryer might be the best option.

However, there are some drawbacks to these types of dryers. They’re limited to low capacity installations, with models ranging from less than 1 SCFM up to 200 SCFM. This makes them more applicable for point-of-use installations than for an entire compressed air system. The nature in which the membrane dryer works necessitates some of the air to be purged out of the system along with the moisture. To achieve dew points as low as -40°F, this can equate to as much as 20% of the total airflow. When proper filtration isn’t installed upstream, oils and lubricants can ruin the dryer membrane and require premature replacement.

Make sure and ask plenty of questions of your compressor supplier during installation and maintenance of your system so you’re aware of the options out there. You’ll of course want to make sure that you’re using this air efficiently. For that, EXAIR’s wide range of engineered Intelligent Compressed Air Products fit the bill. With a variety of products available for same-day shipment from stock, we’ve got you covered.

Tyler Daniel
Application Engineer
E-mail: TylerDaniel@EXAIR.com
Twitter: @EXAIR_TD