How Much Compressed Air Can YOU Save?

I had the pleasure of speaking with a service technician with a pneumatics company recently…he was finishing up a large project for a customer that involved modifying some machinery to reduce compressed air consumption. After the performance of the newly modified machinery was verified, the customer wanted to know how they could be sure they were indeed saving the amount of air that the project engineer estimated that they would save. That’s when he called to ask about EXAIR Digital Flowmeters.

EXAIR Digital Flowmeters are available for iron pipe up to 6", and copper pipe up to 4".
EXAIR Digital Flowmeters are available for iron pipe up to 6″, and copper pipe up to 4″.

If you follow the famous (to EXAIR blog readers, anyway) Six Steps To Optimizing Your Compressed Air System, you know that this is Step #1. So, was it too late to apply a measurement device? Of course not…in this case, the machinery’s original published compressed air consumption rates were used to compare the new actual usage according to the Digital Flowmeter, and it was simple arithmetic from there.  They installed a Model 9095 Digital Flowmeter for 2″ Iron Pipe on the header supplying the machinery, and were not only impressed with the results of the upgrade, but also enjoy the at-a-glance verification of air flow.

Naturally, if you ask for our assistance in the planning stages of a compressed air optimization project, we’ll encourage you to follow the Six Steps in order. Depending on the nature of the problem(s) and the size & complexity of your system, there may be more or less attention paid to certain steps than others.

For instance, a system that was originally equipped with Receiver Tanks at predetermined locations might allow us to skip right over Step #5. If engineered or automated controls, like our EFC Electronic Flow Control & Pressure Regulators are already incorporated, we can check off Steps #4 and #6.

Receiver Tanks are an ideal solution for intermittent demands for high volumes of compressed air.
Receiver Tanks are an ideal solution for intermittent demands for high volumes of compressed air.
The EFC Electronic Flow Control uses a photoelectric sensor to turn air flow on & off, as needed.
The EFC Electronic Flow Control uses a photoelectric sensor to turn air flow on & off, as needed.
Use an EXAIR Pressure Regulator to limit your air supply pressure to the value necessary to accomplish the task.
Use an EXAIR Pressure Regulator to limit your air supply pressure to the value necessary to accomplish the task.

Regardless of “where” you start with your optimization project, “when” you start should be right now. Leaks and inefficiencies won’t fix themselves. Give us a call, and let’s get started.

Russ Bowman
Application Engineer
Find us on the Web
Follow me on Twitter
Like us on Facebook

The Solution To Intermittent Compressed Air System Loads

I recently had the pleasure of assisting an EXAIR Cold Gun user with an application: the parts that the Cold Guns were supposed to be cooling weren’t always getting as cool as they wanted…they’re thermistors being assembled onto a component, and they need to be below a certain temperature when they test them, so they can make sure they’re set properly. Some were getting to the test station while they were at a temperature above their setpoint, which resulted in a rejection of that part. The user wanted to know what could make the Cold Gun work better at times, and worse at other times.

The Cold Gun Aircoolant System has a Vortex Tube with a preset Cold Fraction (that’s the percentage of air supply that is directed to the cold end), so, assuming a constant compressed air supply pressure and temperature, it’ll produce the same amount of cold air flow, at the same low temperature, continuously. The user told me that they used some pneumatic tools in the area, and that these were supplied off the same header as the Cold Guns. We supposed that, during the tools’ operation (which is largely intermittent, as are the Cold Guns’), that portion of the compressed air system may be experiencing a pressure drop, possibly large enough to affect the Cold Guns’ temperature drop.

This could have resulted in a complicated re-plumbing of the compressed air supply in this area, but they were in luck…they had an unused receiver tank, and were able to install it upstream of the feed to the Cold Guns. This resulted in an undisturbed supply of air at a constant 100psig, regardless of whether, or how many, pneumatic tools were being operated at the same time in this area.

This kind of intermittent pressure drop could just as easily affect an Air Knife used for blow off (causing it to not be able to remove moisture/debris in some spots but not others), a Line Vac’s conveyance rate, an E-Vac’s suction power…and the list goes on…not to mention the reduced performance of the pneumatic tools.

If this situation sounds familiar, give us a call. We can look at your supply and demand conditions, and see if a receiver tank might be the solution. Oh, and if you don’t have one, we do: our Model 9500-60 60 Gallon Receiver Tank is ASME rated, and is ideally sized for a wide range of intermittent demands. Let us know if we can help determine if this is a viable solution for your needs.

Russ Bowman
Application Engineer
EXAIR Corporation
(513)671-3322 local
(800)923-9247 toll free
(513)671-3363 fax
Web: http://www.exair.com
Blog: http://blog.exair.com/
Twitter: twitter.com/exair_rb
Facebook: http://www.facebook.com/exair

Video Blog: Receiver Tanks, When to Use One and How to Set One Up

IMG_2314

In the grand scheme of compressed air systems, Receiver Tanks are an oft overlooked component to a well designed system. The following video discusses when to use a secondary receiver tank and how to set one up. Enjoy!

Neal Raker
Application Engineer
nealraker@exair.com