Video Blog: Gen4 Super Ion Air Knife Conversion

The video below provides details on the simple conversion to the new Gen4 style Super Ion Air Knife from the previous style or the addition of a Gen4 Ionizing Bar to an existing Super Air Knife to add static elimination to an existing blow off.

If you have questions about the Gen4 Super Ion Air Knife or any of the 16 different EXAIR Intelligent Compressed Air® Product lines, feel free to contact EXAIR and myself or any of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

A Tale of Two Super Ion Air Knives

A manufacturer of plastic bottles had a problem with static charge. Right after the bottles are extruded and cooled, they have an apparatus that “unscrambles” them and places them, single file, onto a conveyor. It does so with some fabric belts and plastic rollers. If you know anything of static electricity, dear reader, you probably recognize that there aren’t too many better ways to generate a static charge than to rub plastic against plastic, or (even worse) plastic & fabric together.  Here’s a prime example of the kind of static charge you can get, just from unrolling plastic film.

The separation of the non-conductive surfaces (like when this plastic film is unrolled) is capable of generating an incredible amount of static charge.

Now, the bottle makers didn’t have a static meter, but they didn’t need one to know they had issues:  the bottles that the “unscrambler” was putting on the belt were still very much “scrambled.”  They installed a Model 112209 9″ GEN4 Super Ion Air Knife Kit, to blow ionized air up from under the bottles as they entered the belt conveyor, and they did see what they’d call an improvement, but not quite what they’d call a solution.

Unfortunately, dissipating the static from just about half of the surface area of the bottle was still leaving them with half a problem.  However, by adding a Model 112009 9″ GEN4 Super Ion Air Knife (the 112209 Kit’s Power Supply has two outlets, and its Filter Separator & Pressure Regulator are capable of handling the flow to two 9″ Air Knives,) they were able to blow ionized air down from the other side, and up from where the first one was installed.  A soft “breeze” was all it took…a stronger air flow would have worked against the “unscrambler” anyway…because even at very low supply pressures, the Super Ion Air Knives produce an extremely fast static dissipation rate.

Even with a 5psig supply…which makes for just a “whisper” of air flow, the EXAIR GEN4 Super Ion Air Knife eliminates a 5kV charge in under half a second.

If you’ve got problems with static charge, we’ve not only got improvements; we’ve got solutions. Give me a call to find out how we can help.

Basics of Static Electricity

Here in the Northern Hemisphere, we are in the middle of winter and that means extremely dry air, and frequent shocks when reaching for a door knob after walking across a carpeted surface.  While a shock is mildly uncomfortable and can be annoying to us, the presence of static electricity in an industrial manufacturing process can be much more problematic.

Problems that static cause range from operator discomfort to increased downtime to quality issues.  Dust can cling to product, product can cling to itself, rollers, frames, or conveyors. Materials may tear, jam, curl and sheet fed items can stick and mis-feed. Hazardous sparks and shocks can occur, possibly damaging sensitive electronics.

EXAIR has put together a useful tool, the Basics of Static Electricity white paper with Interactive Regions to help a person learn more about static.

Basics of Static Electricity

 

Topics covered include Electron Theory, Causes of Static Electricity, Triboelectric Series chart, and Types of Static Generation.  Also, the white paper covers the areas of How to Control Static Charge Buildup, Determining the Source of the Static Buildup, Eliminating or Minimizing the Source Causing the Buildup, and Treating Static Buildup.

The Treating Static Buildup is a comprehensive review of the EXAIR Static Elimination products and how each technology is best applied to different processes and applications.

To receive your copy of the Basics of Static Electricity white paper, click the photo above or the link here.

If you would like to talk about static electricity or any of the EXAIR Intelligent Compressed Air® Products, feel free to contact EXAIR and myself or one of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer

Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

Calibration – Keep Your Meters True

EXAIR offers meters to measure the level of physical parameters such as sound and static. Each meter has sensitive electrical circuitry and a periodic calibration is recommended to ensure the meter readings are tried and true.

The model 9104 Digital Sound Level Meter is an easy to use instrument that measures and monitors the sound level pressure in a wide variety of industrial environments. The source of loud noises can be quickly identified so that corrective measures can be taken to keep sound levels at or below OSHA maximum allowable exposure limits.

The sound meter comes from the factory with an NIST (National Institute of Standards and Technology) certificate of accuracy and calibration.  As a good practice, EXAIR recommends a yearly calibration of the instrument, and we offer a service that calibrates the unit to the same NIST standards and provide a written report of the calibration.

The model 7905 Static Meter allows easy one-hand static measurements.  It is useful in both locating sources of high static charge and checking the reduction of static after treatment with an EXAIR Static Elimination product.  The unit is sensitive and responsive, and indicates the the surface polarity of objects up to +/- 20 kV when measured from 1″ away.

It is also recommended that the Static Meter be calibrated on a yearly basis.  EXAIR offers (3) levels of calibration service.  The first two provide calibration in accordance with MIL Standards using accepted procedures and standards traceable to NIST.  The third calibration service conforms to the same Mil Standard, as well as ISO/IEC standards.

Annual calibration service of your EXAIR Digital Sound and Static Meter, along with proper care and storage, will keep your meter performing tried and true for many years, providing accurate and useful measurements.

To initiate a calibration service, give us a call and an Application Engineer will issue an Returned Good number, and provide instructions on how to ship the meter to EXAIR.

If you have questions regarding calibration services for your meters or would like to talk about any EXAIR Intelligent Compressed Air® Product, feel free to contact EXAIR and myself or one of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer

Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB