Basics of the Compressed Air System

Compressed air is used to operate pneumatic systems within a facility, and it can be separated into three categories; the supply side, the demand side, and the distribution system.  In this blog, I will cover each area. 

The supply side is the air compressor, after-cooler, dryer, and receiver tank that produce and treat the compressed air.  They are generally located in a compressor room somewhere in the corner of the plant.  There are two main types of air compressors: positive displacement and dynamic.  The core component of most air compressors is an electric motor that spins a shaft.  Positive displacement uses the energy from the motor and the shaft to change volume in an area, like a piston in a reciprocating air compressor or like rotors in a rotary air compressor.  The dynamic types use the energy from the motor and the shaft to create a velocity with an impeller like centrifugal air compressors.  This velocity converts to a rise in pressure.

How do they work?  Most air compressors are driven by an electric or gas motor.  The motor spins a shaft to push a piston, turn a rotor, or spin a vane.  At the beginning of the air compressor, we have the intake where a low pressure is generated from the displacement to bring in the surrounding ambient air.  Once trapped, Boyle’s law states that when the volume decreases, the pressure increases.  For the dynamic type, the velocity and design will increase the air pressure.  The higher pressure will then move to a tank to be stored for pneumatic energy.  The amount of power required is dependent on the pressure and the amount of air that needs to be compressed. 

The demand side is the collection of devices that will use that compressed air to do “work”.  These pneumatic components are generally scattered throughout the facility.  This would include valves, cylinders, blow-offs, pneumatic clamps, etc.   To condition the demand side, regulators and filters are used.  The Pressure Regulators help to limit the amount of pressure.  For blow-off devices, the lower the air pressure to “do the job”, the less compressed air is used.  To help with the fluctuations in demand, a secondary Receiver Tank can be used.  The demand side can also be a system to do specific jobs. In using pneumatic systems, the “power” must come from the supply side. 

To connect the supply side to the demand side, a compressed air distribution system is required.  Distribution systems are pipes which carry the compressed air from the compressor to the pneumatic devices.  For a sound compressed air system, the three sections have to work together to make an effective and efficient system. An analogy that I like to use is to compare the compressed air system to an electrical system.  The air compressor would be considered the voltage source, and the pneumatic devices would be considered as light bulbs.  To connect the light bulbs to the voltage source, electrical wires are needed which will represent the distribution system.  If the gauge of the wire is too small to supply the light bulbs, the wire will heat up and a voltage drop will occur.  This heat is given off as wasted energy, and the light bulbs will be dim.  The same thing happens within a compressed air system.  If the piping size is too small, a pressure drop will occur.  This is also wasted energy.  In both types of systems, wasted energy is wasted money.  One of the largest systematic problems with compressed air systems is pressure drop.  With a properly designed distribution system, energy can be saved, and, in reference to my analogy above, it will keep the lights on.  To have a properly designed distribution system, the pressure drop should be less than 10% from the reservoir tank to the point-of-use.

Processes lead to continuous improvement.

EXAIR created the “Six Steps to Optimizing Your Compressed Air System”.  By following these tips, you can have the supply side, demand side, and distribution system working at peak efficiency.  If you would like to reduce waste even more, EXAIR offers a variety of efficient, safe, and effective compressed air products to fit within the demand side.  This will include the EXAIR Super Air Knives, Super Air Nozzles, and Safety Air Guns.  This would be the electrical equivalent of changing those incandescent light bulbs into LED light bulbs.  If you wish to go further in enhancing your system, an Application Engineer at EXAIR will be happy to help you. 

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

Photo:  Lightbulb by qimono.  Pixabay Licence

Intelligent Compressed Air: System Equipment

At the end of Naval Nuclear Power School, students who’ve just spent two years learning how to boil water must pass a comprehensive examination board before they’re released into the fleet as real live “Navy Nucs.” One popular question at these boards (in 1987 anyway) was to describe, in detail, the path a drop of seawater takes to become reactor coolant (a warship at sea must be self-reliant, and that includes making our own pure water.) A correct answer would prove the student’s knowledge of various piping systems, the steam distilling and water purification processes, reactor coolant chemistry maintenance, and, if you were lucky, a deep dive into the Six Factor Formula which mathematically defines the six events* that affect the probability of neutron multiplication, and hence, the sustainability of nuclear fission in the reactor core:

*Two of these six events relate to the thermalization of neutrons by the coolant. That’s why it’s considered to be a valid part of the ‘seawater-to-reactor-coolant’ question.
The block on the left represents a cubic foot of air at atmospheric pressure. The one on the right represents how much space the first one takes up when compressed to 100psig.

In that same vein, for today’s EXAIR blog, I thought I’d trace a Standard Cubic Foot (SCF) of air from the compressor room, through a typical industrial compressed air system, to its point of use. First, let’s define what that is: Imagine a cubic foot of air in front of you. If the atmospheric pressure is 14.5psia (average for sea level elevation), the ambient temperature is 68°F, and relative humidity is 0%, then that’s one Standard Cubic Foot of air. Now, let’s say this air is in an ideal compressor room – ‘ideal’ meaning those atmospheric conditions apply – and follow its path to an EXAIR Super Air Knife:

  • Filter, Part 1 (intake): When the air compressor draws our SCF in, it passes through filtration media to remove impurities like dust, oil, and moisture. It’s important to remember that this filter is there to PROTECT THE COMPRESSOR from those contaminants, not to provide any measure of cleanliness to the compressed air itself.
  • Compression: This is where our SCF gets compressed by reciprocal or rotating elements imparting energy to it, and it now occupies considerably less space than it did in the atmosphere. This also raises the temperature. When all the molecules that comprise our SCF get closer together, they run into each other more often, and that increased friction makes them hotter. Which can be bad, unless we do something about it.
  • After cooler: Hot compressed air can cause unsafe surface temperatures and can damage gaskets, seals, or other components in the downstream system. Cooling our SCF down is the first thing we want to do after compressing it.
  • Filter, Part 2 (discharge): While the Intake Filter takes care of impurities that could have damaged the compressor, the compressor itself can add some back into our SCF – like oil, wear particulate from meshing gears or seals on moving parts, etc. You’ll want to remove those as well, before letting them go any further in the system. Contaminants like that can really do a number on the operation and effectiveness of some types of dryers.
  • Dryer: While the intake filter removes some finite amount of moisture from our SCF before compression, the compression cycle increases the moisture concentration of it. Dryers come in different types and configurations, each with their own pros & cons, and certain types are more suitable for certain situations. Here’s a link to a blog on the subject by Jordan Shouse that’s both informative and entertaining!
  • Primary Storage: Once our SCF gets cooled, cleaned, and dried, it can take a little break if it’s not needed right away, in a receiver tank. Such a tank, like EXAIR’s Model 9500-60 60 Gallon Receiver Tank (right), near the compressor discharge, serves several purposes:
    • It maintains header pressure during any load transients that happen too quickly for the compressor to keep up in real time.
    • It provides further moisture removal, as any water that condenses in this receiver can be drained from a valve on the bottom.
    • It also allows the compressed air to cool further.
  • Distribution Header Piping: This is the “highway,” if you will, that our SCF travels to where it’ll be used. It’s not alone, either – there are sometimes hundreds, if not thousands, of other SCF’s passing through every minute. And if it’s not appropriately sized, there’ll be problems akin to traffic jams on crowded roads. The appropriate size and layout of the header piping will be determined by a number of factors – here’s a link to a blog with more details on that.
  • Airdrops: These are the branches from the distribution header that lead to the various points of use in the facility. Our SCF will take whichever one it gets directed to…in this case, the aforementioned EXAIR Super Air Knife. The proper size of the drop piping or hose will be determined by the compressed air consumption of the load(s) serviced by the drop, and its length from the header. In the case of our EXAIR Super Air Knife that our SCF is heading towards, the recommended in feed pipe sizes are listed in the Installation/Maintenance Guide:
The longer the drop length, the larger the diameter needs to be to compensate for line loss due to friction.
  • Filter, Part 3 (point of use): Good engineering practice calls for point-of-use filtration. Our SCF has already been through two filters, I know, but it’s also potentially picked up some more contamination along the way. Rust from the inside walls of iron pipes is the most common culprit. The EXAIR Super Air Knife that our SCF is heading towards needs its supply to be filtered for particulate to a level of 10 microns or less. EXAIR Automatic Drain Filter Separators have 5-micron particulate elements, and centrifugal elements that ‘spin’ out any remaining moisture. Depending on the needs of the application, we also have Oil Removal Filters with coalescing elements for oil/oil vapor. They also provide additional particulate filtration to 0.03 microns.
  • Regulator: It’s taken a good deal of effort and expense to get our SCF to this point, so it only makes sense to use it as efficiently as possible. A Pressure Regulator allows us to precisely ‘dial in’ the supply pressure so that we don’t use it (or any of the other SCF’s that it’s traveling with) any more than needed.
EXAIR Automatic Drain Filter Separators (left) can be directly coupled to Oil Removal Filters (center) and Pressure Regulators (right) for a compact installation, free from threaded connections.
EXAIR’s award-winning EFC Electronic Flow Control is a ‘plug and play’ system that can save you THOUSANDS of dollars in compressed air costs.
  • Shutoff valve: Years ago, I talked to an engineer at a company that was using one of our Super Air Knives to blow off parts that were passed in front of it by a robot. The robot’s arm turned & rotated the part in the air curtain to ensure it got completely blown off. This only took a couple of seconds, as the operators had ‘tweaked’ the arm movement to do it as quickly as possible. However, there were about 15 seconds between parts…and the Super Air Knife WAS BLOWING THAT WHOLE TIME. Since they’d already told me how great their automation techs were at programming the robot, I suggested that they go one more step and install a Solenoid Valve in the supply line to the Super Air Knife and use the robot’s logic to open it right before the robot got there, and close it right after the robot left. Step Four of our Six Steps To Optimizing Your Compressed Air System is to “turn off the compressed air when it’s not in use,” and by doing so, they reduced the compressed air consumption of this one Super Air Knife by about 80%. THAT’S optimized. If you don’t have existing logic to do this, our EFC Electronic Flow Control will do it for you.
  • The Super Air Knife: At long last, our SCF is ready to fulfill its purpose, and the Super Air Knife will help it do so in the most efficient way possible. It uses that SCF of air, along with all the others that pass through, to entrain a WHOLE BUNCH of SCF’s from the surrounding environment. The amplification ratio for EXAIR Super Air Knives is 40:1, making them the most efficient compressed air-blowing products on the market.
EXAIR Super Air Knives come in lengths from 3″ to 108″, and are available from stock in aluminum, 303SS, 316SS, or PVDF.

It’s been a LONG time since I’ve used the Six Factor Formula for the neutron life cycle in nuclear fission (and honestly, I haven’t missed it all that much), but every day, I use formulas and figures related to:

Just to name a few. If you’d like to “math something out,” (just not the Six Factor Formula, please), give me a call.

Russ Bowman, CCASS

Application Engineer
Visit us on the Web
Follow me on Twitter
Like us on Facebook

Intelligent Compressed Air: Air Compressor Isentropic Efficiency

If you’re reading the EXAIR blog, odds are you’re interested in getting the most out of your compressed air system. While using engineered compressed air products is certainly one of the best ways to do that (see our Six Steps To Optimizing Your Compressed Air System), there are some things you can look at on the supply side as well. One such metric – and a key one, at that – is isentropic efficiency.

In a nutshell, isentropic efficiency is a measure of how well an air compressor converts the electrical energy it consumes into compressed air. The basic formula is a ratio between the compressor’s actual performance to that of an ideal compression process. Mathematically, it’s expressed as:

Now, as long as air compressors have moving parts, the actual energy consumed will always be higher than the amount of energy required for an ideal process. That’s because the ideal process ignores inescapable losses due to friction between – and inertia of – moving parts, electrical losses (motor efficiency), pressure drops, and heat of compression. So, like any other machine or engine, you’ll never get 100% efficiency.

It’s still a great idea to look for the highest efficiency. So great, in fact, that the U.S. Department of Energy, just this month, began efficiency regulation for oil-flooded rotary air compressors, meaning these compressors will have to meet minimum standards of isentropic efficiency. Specific Power used to be the standard by which an air compressor’s efficiency would be evaluated. It’s the ratio of power consumption to the amount of compressed air produced, normally expressed as kW/100CFM. That doesn’t take the compressor discharge pressure into consideration, which does indeed affect the power needed to generate a given amount of compressed air. We know that a 2psi pressure change will result in a 1% change in power consumption. So, if one manufacturer reports the Specific Power as kilowatts per 100 CFM @100psig, and another reports it as kilowatts per 100 CFM @140psig, that 40psi difference means a 20% variance.

Now, that doesn’t mean we stop using Specific Power – it’s one of the two variables in the isentropic efficiency equation. The other being, of course, the discharge operating pressure:

Where:

  • 16.52 and 0.2857 are constants
  • p2 is the discharge operating pressure (psig)
  • 14.5 is atmospheric pressure (psi) – this corrects gauge pressure to absolute pressure
  • P2 is Specific Power

The Compressed Air & Gas Institute (CAGI) publishes data sheets that are analogous to the fuel efficiency stickers on new car windows. Here’s a sample of one:

And, using the isentropic efficiency formula:

We get an isentropic efficiency of 86.50% (close enough to the CAGI Data Sheet’s 86.47%; likely due to a significant figure discrepancy in the calculations), which is pretty good. The highest published isentropic efficiency is about 92%. At EXAIR, our mission is to help you get the most out of our products and your compressed air system. If you have questions, we’ve got answers – give me a call.

Russ Bowman, CCASS

Application Engineer
Visit us on the Web
Follow me on Twitter
Like us on Facebook

Variable Speed Drive Air Compressors

Compressed air is a clean utility that is used in many different ways, and it is much safer than electrical or hydraulic systems.  But most people think that compressed air is free, and it is most certainly not.  Because of the expense, compressed air is considered to be a fourth utility in manufacturing plants.  I did write a blog earlier titled, “Basics of Compressors”.  There are two main types of speeds for air compressors; fixed and variable.  In this blog, I will cover the Variable Speed Drive (VSD) Air Compressors. 

The VSD Air Compressor controls the speed of the electrical motor by supplying different frequencies and voltages.  It can range from around 20% capacity to 100% capacity depending on the system requirement.  With most systems, the amount of air flow fluctuates throughout the day.  With a VSD Air Compressor, it can run at lesser horsepower ratings for lower demands.  If your plant operates at different compressed air demand levels, the VSD air compressor can help cut the electrical cost. 

 As an example, let’s say you have a 20-horsepower air compressor which can produce roughly 100 SCFM of compressed air.  If the demand drops to 20 SCFM, then the VSD can change the ratio of the electric motor to run like a 4-horsepower compressor.  And a 4-horsepower compressor uses much less electricity to generate compressed air. 

Overall, the VSD does offer better efficiency if there are fluctuations on the demand side.  To go even further, EXAIR has been manufacturing Intelligent Compressed Air Products since 1983.  We are able to save you money by reducing the use of compressed air on the demand side.  Together with a VSD air compressor, our products will help a compressor system to operate at much lower electrical power, saving you money.  If you need alternative ways to use your compressed air, an Application Engineer at EXAIR will be happy to help you. 

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

Photo: Technical Illustration of a portable single-stage air compressor by Brain S. Elliot.  Creative Commons CC BY-SA 4.0