Gen4 Stay Set Ion Air Jet Solves Printing Problem for PVC Manufacturer

We have mentioned here on the EXAIR Blog numerous times just how bad static can get in cooler, dryer regions with low humidity. The amount of moisture in the air is expressed as relative humidity. This value is given as a percentage of water vapor in the air, compared to how much it could hold at that temperature. In conditions of lower relative humidity, static charges build up much easier. When the relative humidity is high, there’s a higher concentration of water molecules present in the air. These water molecules “coat” the surface of the material, allowing electrons to move more freely and form a layer over the material. This layer of water molecules acts like a lubricant, reducing the forces that cause static to generate. There are many applications that static may only pose an issue once the climate changes. 

This could lead one to deduce that tropical climates don’t experience static, given the high humidity present in these areas. While it may be LESS common to experience static troubles in humid conditions, it’s far from impossible.

Such was the case during my recent visit with our partners in Costa Rica. A client of theirs that handles a variety of extruded PVC pipes and shapes was having some problems with a printing process. In their line, after the pipes are extruded, they must mark a batch code and company name on the outside of the pipe. On some days the residual static charge is so high that the ink won’t properly adhere to the outside of the pipes.

A process that should be automatic was requiring them to station an operator nearby to keep an eye on the printer. When issues arise, they must stop production, clean the marking off, and run it back through again. They don’t have the man-power to allocate a person to stand there and monitor things continuously, so this has led to some batches going out marked wrong and leading to rejection and subsequent return.

Fortunately, EXAIR has a wide variety of products designed specifically for use in treating industrial static problems. After checking out the application, it was clear that one of our Ion Air Jets was going to provide a great solution for the customer. Since the specific location of the marking varies depending on the diameter of pipe, they needed something that could also be adjusted. I recommended our Stay Set Ion Air Jet to be installed just prior to the printing head and directed onto the pipe where we’re to apply the marking.

After installation, they continued to monitor closely for a few shifts and managed to make it through a complete day without any rejected material. They no longer have a need to monitor this step in the process and can free up personnel for more important tasks in the facility.

As winter draws to a close, don’t assume static will just automatically go away when the warmer temperatures of spring and summer arrive. In some cases, as was in this application, static can be present despite humid conditions.

Tyler Daniel, CCASS

Application Engineer

E-mail: TylerDaniel@EXAIR.com

Twitter: @EXAIR_TD

Is PVC Pipe Alright to Use with Compressed Air?

A question arises every now and then on whether or not PVC pipe, yes the stuff from your local hardware store that says it is rated for 200 psi, is safe to use as compressed air supply line.   The answer is always the same,  NO! OSHA agrees – see their statement here.

Schedule 40 PVC pipe is not designed nor rated for use with compressed air or other gases.  PVC pipe will explode under pressure, it is impacted significantly by temperature and can be difficult to get airtight.

PVC pipe was originally designed and tested for conveyance of liquids or products that cannot be compressed, rather they can be pressurized.   The largest concern is the failure method of the piping itself.   When being used with a liquid that cannot be compressed, if there is a failure (crack or hole) then the piping will spring a leak and not shatter.   When introducing a compressed gas, such as compressed air, if there is a failure the method ends up being shrapnel.  This YouTube video does a good job of illustrating how the pipe shatters.

While it may seem that it takes a good amount of pressure to cause a failure in the pipe, that is often not the case.  I have chatted with some local shop owners who decided to run PVC as a quick and cheap alternative to get their machines up and running.

They each experienced the same failures at different points in time as well.  The worst one was a section of PVC pipe installed over a workbench failed where an operator would normally be standing. Luckily the failure happened at night when no one was there.  Even though no one got injured this still caused a considerable expense to the company because the compressor ran overnight trying to pressurize a ruptured line.

Temperature will impact the PVC as well. Schedule 40 PVC is generally rated for use between 70°F and 140°F (21°-60°C). Pipes that are installed outside or in non temperature controlled buildings can freeze the pipes and make them brittle.

If you haven’t worked with PVC before or do not let the sealant set, it can be hard to get a good seal, leading to leaks and a weak spot in the system.

The point of this is the cheapest, quick, and easy solutions are more often , the ones that will cost the most in the long run.

If you would like to discuss proper compressed air piping and how to save compressed air on your systems, please contact us.

Brian Farno
Application Engineer
BrianFarno@EXAIR.com
@EXAIR_BF

 

Image courtesy of: Dennis Hill, Creative Commons License

The Versatile Line Vac

Of all the tools that I own, my cordless drill has to be just about my favorite. I’m remodeling a bathroom in my house right now, and last night I was setting the new toilet flange onto the new tile floor. I had to drill some holes for this through the new tile. I’d never done this before, and was definitely feeling some heartburn about it. Especially after finding out just how fragile and brittle ceramic tile is…I cracked two pieces, just trying to cut a hole for the heat & AC vent register. Luckily, that was BEFORE I mortared & grouted it in, so it wasn’t a big deal…they’re about a buck a piece, and I got five extra anyway.

I know how to do this...but I have no idea how to fix this.
I know how to do this                                                 but I have no idea how to fix this.

THIS one, though, was fully installed, and, despite all the internet videos I found & watched on how to install a tile floor, I haven’t yet had the need to find one that shows me how to replace a broken tile. And I don’t really want to, so I went slowly and carefully with the drill, using the special glass & tile bit that I bought. On my first hole, when I got the bit through the tile itself, I changed to a different (smaller) bit to pilot the screw hole through the subfloor. Then, I put a Phillip’s head bit in to drive the screw. It occurred to me that I was performing these three related but separate tasks, with the same tool…I just thought that was very cool.

Over the course of the last couple of days, I’ve talked to three different callers, with three different Line Vac applications:

HDLV

 

*One wants to use a Model 150200 2” Heavy Duty Line Vac to convey cement. They’re currently hauling the bags, by hand, up to a hopper, where they cut them open and dump them in.

 

Heavy Duty Threaded Line Vac

*One needs to move small springs, one at a time, from a hopper to an automated assembly turret machine.  The springs are 5/8″ in diameter, and they’ll be fed through a length of PVC pipe.  Our Model 151100 1″ NPT Heavy Duty Threaded Line Vac will be easily installed in the pipe line using standard threaded fittings, and the springs will pass through the 0.75″ throat nicely.

 

sslv

 

*One has a auger-type chip conveyor that removes machining debris from a lathe, and it’s broken…again. They needed a Model 6066 3” Stainless Steel Line Vac, in a hurry, to use until they get their chip conveyor fixed. In fact, if it works, they may not fix the chip conveyor.

 

With a wide range of sizes and materials of construction, we've got your solution.  Call us.
With a wide range of sizes and materials of construction, we’ve got your solution. Call us.

So, kind of like my cordless drill, our Line Vac Air Operated Conveyors have a variety of uses, right out of the box. If you have an application that you think a Line Vac may be able to solve, give me a call.  By the way, if you order one before the end of October, 2014we’ll give you a FREE 2″ Flat Super Air Nozzle.  Really.

Russ Bowman
Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook