Electricity and water don’t mix. Electrical and electronic components don’t like many contaminants that can be found in industrial settings, either. Exposure to moisture or dirt are surefire ways to “let the smoke out” – it can be just as bad as letting them overheat. Once that’s happened, replacement of the failed components is usually the only option. THAT can get expensive not only in the cost of the component, but also in the downtime waiting for it to come in…which can be a REAL problem if they’re not in stock.
Luckily, there’s no shortage of cooling devices for electrical panels. They all have certain areas/situations where they’ll work just fine, but most have areas/situations that can cause real problems:
Panel air conditioners work a lot like the a/c in your home or office, and if you’ve ever used window a/c units, they work EXACTLY like those. Since they cool the air as they recirculate it through the space, they have filters to catch any particulate. If the panel isn’t sealed tightly, this filter may very well require regular attention. They also use air from the surrounding environment to condense the hot refrigerant gas:

Compressor: pressurizes low pressure refrigerant gas.
Condenser: transfers heat from hot, high pressure refrigerant gas to outside air.
Expansion valve: lowers pressure (and temperature) of condensed refrigerant, sending it to the evaporator to continue the heat transfer cycle.
If the condenser coils are exposed to contaminants (dust, oil, chemical vapors, etc.), they’ll be subject to fouling & corrosion, making panel air conditioners more prone to failure in more aggressive environments. Also, since they use air from the environment as a heat sink for the refrigerant, their cooling capacity is inversely affected by the ambient temperature.
Heat Pipe systems also use refrigerant, but they don’t have any moving parts to wear. Since they don’t have a compressor or expansion valve, though, they’re incapable of cooling the panel below ambient temperature. The evaporator fins or coils are also still subject to environmental contamination, so they have the same limitations as a panel a/c system…and are further limited in hot spaces.
Panel fans are easily the least expensive cooling method. They’re usually fitted with filters for the outside air that they move through the enclosure. Like heat pipes, they can’t cool the enclosure to a temperature below ambient for the area, and the filters are still subject to clogging from airborne particulate, and since those filters have to be coarse enough for the fan’s cooling air flow, smaller particulate can still make it inside the panel….along with any vapors or gases that could condense, or worse, corrode components inside the panel. If the fan on a home computer can get as dusty as the one in the photo to the left, imagine how much worse the one on a control panel on a factory floor can get.
Liquid to Air coolers use liquid – the most common being chilled water – for cold fluid flow through coils inside the panel to remove heat, which is then transferred to ambient through a refrigerant chiller, or a fan & radiator. The inside coils are subject to fouling and condensation if the panel isn’t sealed tightly, and the refrigerant chiller has the same limitations as a panel a/c unit. If it uses a fan & radiator, it (like panel fans or heat pipes) can’t cool the panel to less than ambient temperature in the area.
EXAIR Cabinet Coolers have no moving parts and use compressed air as the sole cooling medium, so they’re not affected at all by environmental conditions. When they’re properly installed on a sealed enclosure, the only thing the inside of the enclosure ever sees is clean, cold, moisture-free air. Wherever your panel is, and regardless of the environment, EXAIR has a wide selection of cooling capacities, features, and materials of construction. Consider:
- Cooling capacities from 275 to 5,600 Btu/hr. Call me if your heat load is outside this range…we can look at customized solutions too.
- NEMA 12 (IP54), NEMA 4, or NEMA 4X (IP66) ratings.
- Thermostat Control – Standard, or Electronic Temperature Control.
- Non-Hazardous Purge for contaminant exclusion on less-than-ideally sealed enclosures.
- High Temperature models for ambient temperatures from 125°F (52°C) to 200°F (93°C).
- Side Mount Kits where space is limited above the panel.
- 316SS construction for particularly aggressive environments.
- UL Classified systems for hazardous locations: Our HazLoc systems are approved for Class I Div 1, Class II Div 1 & Class III areas, and ATEX systems are approved for Zones 2 & 22.