More Efficient Compressed Air Use Could Lead To Energy Rebates

The use of compressed air can be found in almost any industry and is often referred to as a “fourth utility” next to water, gas and electric. The generation of compressed air accounts for approximately 1/3 of all energy costs in an industrial facility, in many cases, it’s the largest energy user in an industrial plant. With an average cost of $ 0.25 per every 1,000 SCF used, compressed air can be expensive to produce so it is very important to use this utility as efficiently as possible.

Utility companies recognize the benefit of using engineered products to reduce compressed air usage, like the ones manufactured by EXAIR, and offers rebate incentives for making a switch. Our local utility provider here in Cincinnati, Duke Energy, offers a $ 20 incentive for each replacement engineered nozzle.

 

Our Model # 1100SS 1/4″ FNPT and Model # 1101SS 1/4″ MNPT Super Air Nozzles

In their specification, the nozzle must meet a certain volumetric flow rate (SCFM) at 80 PSIG operating pressure for a given pipe size. For example, when looking at a 1/4″ nozzle, the flow rate must be less than or equal to 17 SCFM when operated at 80 PSIG. Our most popular nozzles for “general” blowoff applications would be our Model # 1100 (1/4″ FNPT) or our Model # 1101 (1/4″ MNPT) Super Air Nozzles. These nozzles require 14 SCFM @ 80 PSIG so this would be the ideal solution to reduce the air demand and take advantage of the rebate.

Here at EXAIR, much of our focus is to improve the overall efficiency of industrial compressed air operating processes and point of use compressed air operated products. If you’d like to contact one of our application engineers, we can help recommend the proper engineered solution to not only save on your compressed air usage but also assist with possible energy rebates available in your area.

Justin Nicholl
Application Engineer
justinnicholl@exair.com
@EXAIR_JN

 

 

Engineered Nozzles Replace Segmented Coolant Hose for Ink Drying Application

flat nozzle loc line comparison
Segmented Hose on the left and an HP1126 1″ Flat Nozzle on the right

A common item that can be found in a majority of machine shops is the blue or gray knuckle-jointed hose used to dispense coolant on lathes and CNC machines. EXAIR also uses this same hose with our Cold Guns and Adjustable Spot Coolers for applications that cannot or do not wish to use liquid coolant as a means of keeping the heat down on their tooling. Since the cold air discharges at atmospheric pressure, this is an acceptable application. Another application is using this style of hose as a compressed air blowoff. This is NOT a proper use of the hose and is not only a considerable waste of compressed air but can also pose a safety hazard. Using this method for compressed air blowoff is not compliant with OSHA 1910.242(b) (a directive we blog about).

I was recently contacted by a customer in Indonesia that was using an array of (6) of these knuckle-jointed hoses with a ¼” round nozzle attachment for a blowoff operation. The customer had a series of rubber pads used in the construction of a toy castle. The pads were brought along by an overhead conveyor and a design was printed on the head of the pad. The nozzles were used to dry the ink before the pad made it to the next part of the process. This was a new product line and the processes involved were being evaluated for potential places to save on compressed air rather than adding overall capacity to their system. After using a variety of EXAIR products for other blowoff applications, they came back for another engineered solution.

After testing both a 1009-9280 (Adjustable Air Nozzle w/ 30” Stay Set Hose) and an HP1126-9280 (1” High Power Flat Nozzle w/ 30” Stay Set Hose), the customer determined that the airflow pattern from the 1” Flat Nozzle was more conducive to drying the rubber pad and purchased the remaining units to replace their original method. The compressed air savings was noticed immediately!!

For the old operation, they had to regulate the pressure down on the hose to 25 psig so that the hose wouldn’t break apart. (1) This hose , with a ¼” round nozzle, will consume 52 scfm at 25 psig of supply pressure. With (6) of these they were consuming a whopping 312 scfm!! Since the HP1126 is compliant with OSHA directive 1910.242(b) and will not break apart at higher pressures, they were able to operate at 80 psig while only consuming 17.5 scfm. They saved more than enough air for their new process and are evaluating whether or not they can turn off one of their smaller 25 HP compressors.

The new setup with the EXAIR engineered solution was able to save them 207 scfm of compressed air. Assuming a cost of $.25/1000 scfm and a 40 hr work week, this translates to an overall savings of $6,458.40 per year off of their utility bill.

207 scfm x 60 minutes x 8 hrs/day x 5 shifts/week x 52 weeks/year =25,833,600 scf

25,833,600 scf x ($.25/1000 scf) = $6,458.40

If you’re using an inefficient compressed air blowoff in your facility, give us a call. An Application Engineer will be happy to evaluate your process and determine the safest and most efficient solution. With same day shipment for stock items on orders placed by 3:00 pm EDT, we can get a solution out to you by the following day!