Father’s Day Weekend & Leak Detection

In case you didn’t know, yesterday was Father’s Day. In our household, both Father’s Day and Mother’s Day are pretty low-key, and we normally just get some much-needed family time in. This year for Mother’s Day we prepared the patio and outdoor living space at our home for the Summer activities. For Father’s Day, the schedule was a little different. My wife and oldest had a play to go to in the early afternoon and I had a list of repairs to do as well as some recovery from a dodge ball tournament on Saturday. While most of my repairs were things like fixing a leaking hose, unpacking from the tournament, and weeding the garden, I did not have any major repairs on my list which meant I could take the younger two daughters and head to the pool. That ice-cold water definitely helped with the recovery part of my day, so we went. Met the rest of the crew after their show and had some nice ice cream time then home. I was feeling pretty good as my tasks were all completed, and I was going to be able to just enjoy the meal my wife had fixed for dinner and play some games with my girls. Well, the house had other plans, we arrived home to a thermostat that had crept up while we were gone.

Ice from the compressor line in the condensing coil.
While the leak detector wasn’t out, there was no shortage of thermometers being used here along with a slide rule. (Leak Detection had been completed.)

Now, our HVAC system has limped along for probably a decade longer than most, and we continue to regularly maintain it. This is a true testament to how well preventative maintenance can truly expand the life of an item. Needless to say, during my routine inspection and maintenance at the start of the year, we found the unit was low on refrigerant. One of the first steps we performed when we saw it was starting to freeze up was to begin testing for leaks. This task takes a special gas detection meter that will sniff out the refrigerant vs. just air movement. Sure enough, we found a corroded joint in the A-Coil that has developed a fairly considerable leak. This tool made me think of the Ultrasonic Leak Detector that we sell here at EXAIR. It also made me start to correlate how a leak in a refrigeration system can cause the entire process to ice over because there isn’t enough refrigerant present and so the entire system begins to work harder and harder and the coil temp drops below freezing. The humidity in the air begins to collect on the A-Coil inside the house because the coil is so much cooler than the humid air around it and the ice starts to form. Once the ice forms you restrict the airflow through the coil which causes more ice to form and eventually no airflow happens and the entire compressor line will freeze. This often can lead to other failed parts if not discovered early enough. How is this like a compressed air system?

Well, leaks in a compressed air system cause the compressor to work overtime. It drops efficiency within the other items in the system which creates a lack of performance and potentially shuts down the system. Leaks can be found by utilizing a less specialized, Ultrasonic Leak Detector which can be seen in operation in the video below. Fixing these leaks can easily put capacity back in and save additional maintenance and replacement costs.

If you want to discuss how the Ultrasonic Leak Detector can save you money and costly shutdowns, contact an application engineer today.

Brian Farno
Application Engineer
BrianFarno@EXAIR.com
@EXAIR_BF

General Guidelines for Maintaining Your Compressed Air System

Performing regular maintenance on your compressor system helps to keep everything operating in peak condition and ensures you’re not wasting unnecessary energy. Just as you perform regular routine maintenance on your vehicles, a compressed air system also needs a little TLC to keep things running smoothly. Neglected maintenance items can lead to increased energy costs, high operating temperatures, and coolant carryover. Much of these issues can be eliminated simply by performing routine maintenance on the components of the system.

According to the Best Practices for Compressed Air Systems by the Compressed Air Challenge (1), components within the system that need maintained include: the compressor, heat exchanger surfaces, lubricant, lubricant filter, air inlet filter, motors, belts, and air/oil separators.  

The compressor and all surfaces of the heat exchanger need to be kept clean and free of contaminants. When these components are dirty, compressor efficiency is greatly reduced. Any fans and water pumps should also be regularly inspected to ensure that they’re functioning properly. The air inlet filter and piping should also be cleaned. The quality of the air in the facility will impact the frequency, refer to the manufacturer’s specifications for ideal intervals for performing scheduled maintenance.

The lubricant and lubricant filter must also be changed per manufacturer’s specifications. Old coolant can become corrosive, impacting useful life and damaging other components while reducing efficiency. While synthetic lubricants are available that have an extended life compared to standard coolants, this does not extend the life of the lubricant filter itself.

Belts should be routinely checked for tension (every 400 hours is reasonable) to alleviate bearing wear. Belts will stretch and wear under normal operation and must be adjusted periodically. It’s a good practice to keep some spares on hand in the event of a failure.

End use filtersregulators, and lubricators should also be periodically inspected and filter elements replaced as needed. If left unchecked, a clogged filter will increase pressure drop. This can cause both a reduction of pressure at the point of use or an increase in the pressure supplied by the compressor, leading to increased energy costs.

Another often overlooked maintenance item is leak detection and repair. Leaks contribute to unnecessary air usage, pressure drop, and increased energy costs. EXAIR offers an Ultrasonic Leak Detector that can be used to identify the leaks in your system and allow you to make the necessary repairs.

EXAIR Ultrasonic Leak Detector

In order to keep your system running in peak condition, regular maintenance is critical. By paying close attention to the manufacture’s recommendations, and implementing a regular maintenance schedule, you can ensure you’re getting the most out of your system components.

Tyler Daniel, CCASS

Application Engineer
E-mail: TylerDaniel@EXAIR.com
Twitter: @EXAIR_TD

(1) Scales, W. (2021). Best Practices for Compressed Air Systems : Second Edition (2nd ed.). The Compressed Air Challenge,.

Compressor system image courtesy of Compressor1 via Flickr Creative Commons License Attribution-NoDerivs 2.0 Generic

Saving Compressed Air – The Fourth Utility

We all know the value of electric, water and gas but what about compressed air? Your compressed air system has an annual cost and deserves to be treated as a cost center. In my previous career, I was guilty of not having a budget for compressed air in my business plan and wish I knew then what I needed for a more efficient compressed air system. Compressed air carries a significant value and deserves to be a cost center with aggressive annual efficiency planning.

Unfortunately, several misconceptions about how to reduce energy costs through increased compressed air efficiencies have prevented many industrial operations from taking control of their compressed air energy costs. There are 2 main focuses about compressed air systems that can begin to reduce expenditures, improve the reliability of your systems and generate savings for future equipment improvements. First, you can look at energy savings in the compressor motors but this is a more complicated and more expensive endeavor that can be a next step when tackling compressed air savings head on. Second, the demand side of the compressed air system is where many efficiencies can be gained. A focus on leaks, storage, pressure and inefficient use are generally simple and inexpensive to address.

Increasing the pressure isn’t always the answer. In fact, frequently it is not. An efficient compressed air system is characterized by stable pressure levels. Steady pressure levels are achieved by addressing two things: air demand patterns and the minimum acceptable pressure level required for reliable production. Unfortunately, many operators who fail to properly diagnose the causes of system problems simply increase pressure to improve performance. Arbitrary increases to the pressure without understanding the root causes of performance issues can lead to increased energy costs. An audit completed by your compressed air specialist will reveal which aspects of your compressed system can be fine-tuned in order to reduce energy costs and increase reliability. Use of the “Six Steps to Optimizing Your Compressed Air System” will help achieve your goals for cost savings and efficiencies.

Begin with establishing a baseline for your system and learn what your typical air use looks like. This can be done with a flow meter installed at the compressor outlet. A flow meter is also useful at each machine or process demanding compressed air because they can (1) indicate if a machine or process is operating atypically and consuming more air than usual and (2) identify where high demand machines or processes are located in your facility.

It is estimated that up to 20% of compressed air produced by industrial air compressors is wasted due to leaks in typical facilities.¹ Approximately 20% of the air produced for industrial applications ends up being lost through leaks. The use of EXAIRs’ model 9061 Ultrasonic Leak Detector will enhance your efforts in finding leaks.

Choose engineered products to apply compressed air, these product have a focus on efficiency and outperform commercial products which do not concern themselves with air reduction.

When moving around your facility, look for applications of compressed air which can be turned off when personnel are on break or can be turned off in between parts. This step is very simple and can reap big savings.

Be sure to store compressed air close to high demand applications, this will prevent peaks and valleys in your compressed air demand which contributes toward less maintenance for your compressor.

Also lower your pressure at compressed air points of use. Keeping the pressure at the minimum pressure required for a successful application can also help keep system wide pressure to a minimum, which will increase lifetime of your compressor.

The good news is that, in most cases, lower energy costs are completely attainable for industrial operations that have not optimized their compressed air systems. To begin saving please contact EXAIR about compressed air products that can lower your compressed air costs today.

Eric Kuhnash
Application Engineer
E-mail: EricKuhnash@EXAIR.com
Twitter: @EXAIR_EK

  1. Best Practices for Compressed Air Systems, second edition. From The Compressed Air Challenge.

The Basics of a Compressed Air Leak Detection Program

It is no surprise that compressed air can be a costly utility for industrial facilities. It can easily chip away at the bottom line finances if used carelessly and without planning. This is one of the leading reasons we have educated continuously on how to ensure this vital utility is used with safety and conservation in mind. If we have installed all engineered solutions at the point of use throughout a facility, there is still more to be saved. One of the easiest things to do with a utility system inside of a facility is to leave it unchecked and undocumented until something goes wrong. This does not have to be the scenario and in fact, starting a leak detection program in a facility can help to save up to 30% of the compressed air generated.

Leaks cost money!

That’s right, up to 30% of the compressed air being generated in an industrial facility can be exhausting out to ambient through leaks that run rampant throughout the facility. When the point of use production is still working fine, then these sorts of leaks go unnoticed. Another common occurrence goes something like this example: Maybe there is a leak bad enough to drop the packaging line pressure slightly, this may get fixed by bumping up a pressure regulator, production is back up and it is never thought of again. In all actuality this is affecting the production more and more with each leak.

The leaks add additional load onto the supply side. The compressor has to generate more air, the dryer needs to process more air, the auto drains dump more moisture, it all ads up to additional wear and tear also known as false load. All of this additional load on the system can add more maintenance which if left undone can result in system shut downs. One way to begin to eliminate this false load is to deploy a leak detection program. The steps are fairly easy.

Similar to our 6 Steps to Compressed Air Optimization, you start with a baseline of how much air the system is seeing and operating pressures. This begins the documentation process which is critical to the success of the program. Next, acquire an ultrasonic leak detector (ULD) and a layout of your compressed air system piping. Utilizing the ULD, test all compressed air piping along with equipment, and tag each leak that is detected. Next, begin to repair all of the tagged leaks and document the amount of compressed air savings with each repair. This again, is more documentation which leads to giving a quantitative value to the return on investment of the program. Lastly, schedule a follow up scan that recurs on a pre-determined basis to prevent the system from returning to it’s original leaky state.

EXAIR Ultrasonic Leak Detector

If you would like to discuss starting a leak detection program in your facility or have questions about the ULD or any point of use compressed air product, please reach out to an Application Engineer today.

Brian Farno
Application Engineer
BrianFarno@EXAIR.com
@EXAIR_BF