Convective Heat Transfer: How Do We Use It?

Vortex Tubes have been studied for decades, close to a century. These phenoms of physics and the theory behind them have been discussed on this blog before. Many customers gravitate toward Vortex Tubes when needing parts and processes cooled. The fact of the matter is there is still more to be discussed on how to correctly select the which product may be needed in your application. The reason being, area, temperatures, and air flow volumes play a large role in choosing the best product for cooling. The tendency is to say, well I need to cool this down as far as possible so I need the coldest air possible which leads to the assumption that a Vortex Tube will be the right solution. That isn’t always the best option and we are going to discuss how to best determine which will be needed for your application. The first step, is to call, chat, or email an Application Engineer so that we can learn about your application and assist with the implementation of the Vortex Tube or other cooling product for you. You may also want to try and take some initial readings of temperatures. The temperatures that would help to determine how much cooling is going to be needed are listed below:
  • Part temperature
  • Part dimensions
  • Part material
  • Ambient environment temperature
  • Compressed air temperature
  • Compressed air line size
  • Amount of time desired to cool the part: Lastly desired temperature

With these bits of information, we use cooling equations to help determine what temperature and volume of air will best suit your needs to generate the cooling required. One of the equations we will sometimes use is the Forced or Assisted Convective Heat Transfer. Why do we use convective heat transfer rather than Natural Heat Transfer? Well, the air from EXAIR’s Intelligent Compressed Air Products® is always moving so it is a forced or assisted movement to the surface of the part. Thus, the need for Convective Heat Transfer.
Calculation of convection is shown below: q = hc A dT Where: q = Heat transferred per unit of time. (Watts, BTU/hr) A = Heat transfer area of the surface (m2 , ft2) hc= Convective heat transfer coefficient of the process (W/(m2°C), BTU/(ft2 h °F) dT = Temperature difference between the surface and the bulk fluid (compressed air in this case) (°C, °F)

The convective heat transfer coefficient for air flow is able to be approximated down to hc = 10.45 – v + 10 v1/2

Where: hc = Heat transfer coefficient (kCal/m2 h °C) v = relative speed between the surface of the object and the air (m/s)

This example is limited to velocities and there are different heat transfer methods, so this will give a ballpark calculation that will tell us if we have a shot at a providing a solution.  The chart below is also useful to see the Convective Heat Transfer, it can be a little tricky to read as the units for each axis are just enough to make you think of TRON light cycles. Rather than stare at this and try to find the hidden picture, contact an Application Engineer, we’ve got this figured out. convective_heat_transfer_chart

1 – Convective Heat Transfer Chart
Again, you don’t have to figure any of this out on your own. The first step to approach a cooling application is to reach out to an Application Engineer, we deal with these types of applications and equations regularly and can help you determine what the best approach is going to be.
Brian Farno Application Engineer BrianFarno@EXAIR.com @EXAIR_BF
1 – Engineering ToolBox, (2003). Convective Heat Transfer. [online] Available at: https://www.engineeringtoolbox.com/convective-heat-transfer-d_430.html [02/10/2021]

Six Steps To Optimizing Your Compressed Air System – Step 1: Measure

“To measure is to know – if you cannot measure it, you cannot improve it.”
-Lord Kelvin, mathematical physicist, engineer,and pioneer in the field of thermodynamics.

This is true of most anything. If you want to lose weight, you’re going to need a good scale. If you want to improve your time in the 100 yard dash, you’re going to need a good stopwatch. And if you want to decrease compressed air consumption, you’ll need a good flowmeter. In fact, this is the first of six steps that we can use to help you optimize your compressed air system.

Six Steps To Optimizing Your Compressed Air System

There are various methods of measuring fluid flow, but the most popular for compressed air is thermal mass air flow.  This has the distinct advantage of accurate and instantaneous measurement of MASS flow rate…which is important, because measuring VOLUMETRIC flow rate would need to be corrected for pressure in order to determine the true compressed air consumption.  My colleague John Ball explains this in detail in a most excellent blog on Actual (volume) Vs. Standard (mass) Flows.

So, now we know how to measure the mass flow rate.  Now, what do we do with it?  Well, as in the weight loss and sprint time improvements mentioned earlier, you have to know what kind of shape you’re in right now to know how far you are from where you want to be.  Stepping on a scale, timing your run, or measuring your plant’s air flow right now is your “before” data, which represents Step One.  The next Five Steps are how you get to where you want to be (for compressed air optimization, that is – there may be a different amount of steps towards your fitness/athletic goals.)  So, compressed air-wise, EXAIR offers the following solutions for Step One:

Digital Flowmeter with wireless capability.  This is our latest offering, and it doesn’t get any simpler than this.  Imagine having a flowmeter installed in your compressed air system, and having its readings continually supplied to your computer.  You can record, analyze, manipulate, and share the data with ease.

Monitor your compressed air flow wirelessly over a ZigBee mesh network.

Digital Flowmeter with USB Data Logger.  We’ve been offering these, with great success, for almost seven years now.  The Data Logger plugs into the Digital Flowmeter and, depending on how you set it up, records the flow rate from once a second (for about nine hours of data) up to once every 12 hours (for over two years worth.)  Pull it from your Digital Flowmeter whenever you want to download the data to your computer, where you can view & save it in the software we supply, or export it directly into Microsoft Excel.

From the Digital Flowmeter, to your computer, to your screen, the USB Data Logger shows how much air you’re using…and when you’re using it!

Summing Remote Display.  This connects directly to the Digital Flowmeter and can be installed up to 50 feet away.  At the push of a button, you can change the reading from actual current air consumption to usage for the last 24 hours, or total cumulative usage.  It’s powered directly from the Digital Flowmeter, so you don’t even need an electrical outlet nearby.

Monitor compressed air consumption from a convenient location, as well as last 24 hours usage and cumulative usage.

Digital Flowmeter.  As a stand-alone product, it’ll show you actual current air consumption, and the display can also be manipulated to show daily or cumulative usage. It has milliamp & pulse outputs, as well as a Serial Communication option, if you can work with any of those to get your data where you want it.

With any of the above options, or stand-alone, EXAIR’s Digital Flowmeter is your best option for Step One to optimize your compressed air system.

Stay tuned for more information on the other five steps.  If you just can’t wait, though, you can always give me a call.  I can talk about compressed air efficiency all day long, and sometimes, I do!