Sound Power vs Sound Pressure

Noise levels or sound levels are an important consideration in many industrial settings. Noise exposure can cause irreparable damage if the necessary safety precautions are not taken. OSHA standard 29 CFR – 1910.95 (a) addresses this very concern.

But when discussing sound levels, there are two terms that frequently come up – Sound Power, and Sound Pressure. So, what’s the difference?

Sound Power (measured in watts) refers to the rate at which sound energy (measured in decibels) is emitted, reflected, transmitted, or received over time. On the other hand, sound pressure is the local pressure change from ambient atmospheric pressure caused by a sound wave. From these definitions, we can see that sound power is what creates the sound wave, while sound pressure is the result of what we perceive after the sound wave reaches our ears.

A good way of conceptualizing this is to imagine a light bulb. Light bulbs use electricity to produce light, which means the power needed (also measured in Watts) to make the bulb shine is similar to sound power. The brightness of the light produced (measured in lumens) corresponds to sound pressure. Sound pressure is essentially what we hear or refer to as sound. This is what gets measured because it can be harmful to our hearing. If the sound pressure is too high and the ear is exposed for too long, it can lead to permanent damage, hence OSHA’s regulation mentioned above. This regulation is the result of testing performed to determine what time thresholds at which permanent damage to human hearing will occur due to exposure over a period of time. The higher the sound pressure level, the less exposure time necessary to produce irreparable damage. Within this regulation is included a time weighted chart that OSHA follow for noise exposure issues that serve as the metric by which they determine if a company is in compliance. If not, they may recommend engineering changes, work process changes or require the use of PPE (hearing protection) if the other types of controls cannot be implemented.

If you would like a way to measure noise levels in your facility, EXAIR has the perfect product – EXAIR’s Digital Sound Level Meter. We have a video blog covering its benefits and operation here.

Generally speaking, compressed air-generated noise within a facility can be rather prevalent and loud. So, if you would like to discuss how EXAIR’s quiet and efficient compressed air products can help reduce noise levels in your facility, then give us a call!

Al Wooffitt
Application Engineer

Send me an Email
Find us on the Web
Like us on Facebook
Twitter: @EXAIR_AW

Starting a Leak Prevention Program: Maximize Efficiency and Savings

Compressed air systems are the unsung heroes powering countless processes across all industries. However, they come with a hidden cost: leaks. Even the most well-maintained systems experience some level of leakage, often wasting 20-30% of a compressor’s output, according to the Compressed Air Challenge. This inefficiency translates directly into higher energy bills, increased compressor wear, and unnecessary maintenance expenses. The good news? You can take control of these losses by implementing a Leak Prevention Program. Let’s dive into how to establish such a program and why it’s a game-changer for your bottom line.

Compressed air isn’t cheap—it’s often one of the most significant energy expenses in a facility. When leaks go unchecked, you’re not just losing air; you’re losing money. A single leak can cost thousands of dollars annually, depending on its size and your energy rates. For example, at $0.07 per kWh, a leak as small as 1/8 inch can waste over $2,933 worth of compressed air per year. Multiply that by dozens of leaks across a system, and the financial impact becomes staggering. Beyond the dollars, leaks force compressors to run longer and harder, shortening their lifespan and driving up maintenance costs. A Leak Prevention Program isn’t just a nice-to-have—it’s a strategic necessity for operational efficiency and sustainability.

EXAIR provides resources and tools to help you design and execute an effective Leak Prevention Program. Here’s a step-by-step approach to getting started:

  1. Establish a Baseline – Before you can measure improvement, you need to know where you stand. Document your current compressed air usage by tracking compressor run times, energy consumption, and system pressure. This baseline serves as your reference point to quantify savings once leaks are addressed. To measure the total volume of air, you can implement the EXAIR Digital flow meter.
  2. Identify Leaks – Here’s where EXAIR’s Ultrasonic Leak Detector (Model 9207) shines. Leaks produce high-frequency turbulence—ultrasonic “white noise” that’s inaudible to the human ear but easily detectable with the right technology. This handheld, high-quality detector converts these ultrasonic signatures into audible sounds through headphones and displays intensity on an LED screen, allowing you to pinpoint leaks up to 20 feet away. Whether it’s a faulty fitting, a worn valve, or a cracked pipe, the detector’s precision ensures you won’t miss a thing—even in noisy industrial environments.
  3. Document and Prioritize – Once leaks are identified, record their location, size, and estimated cost. There are two main approaches: the Seek-and-Repair method, where leaks are fixed immediately, or the Leak Tag method, where leaks are tagged and logged for scheduled repairs. For larger facilities, a master leak list can streamline tracking and ensure accountability. Prioritize repairs based on leak size and accessibility—tackling the biggest offenders first maximizes early savings.
  4. Repair and Verify Fix the leaks using appropriate methods—tightening connections, replacing seals, or upgrading components. After repairs, use the Ultrasonic Leak Detector again to confirm the fixes hold. This verification step ensures your efforts translate into real results.
  5. Track Savings and Optimize Compare your post-repair compressed air usage to your baseline. The reduction in energy costs, compressor runtime, and maintenance needs will reveal the program’s ROI, then you can turn your leak prevention program into a continuous improvement process.

The EXAIR Ultrasonic Leak Detector is an important building block for this program. Its ability to detect leaks quickly and accurately sets it apart from rudimentary methods like listening for hisses (which only catches the worst offenders) or using soapy water (impractical for large systems). The detector’s portability and ease of use mean your team can cover an entire facility efficiently, even during normal operations. Its directional sensitivity zeros in on leak sources, minimizing guesswork and downtime. With minimal training, your staff can become proficient, making it a practical investment for any operation.

Compressed air leaks will rob your system of its capacity, compressor life, and electrical cost.  It is important to have a leak preventative program to check for leaks periodically as they can happen at any time.  The EXAIR Ultrasonic Leak Detector and the Digital Flowmeters will help you accomplish this and optimize your compressed air system.  Once you find and fix all your leaks, you can then focus on improving the efficiency of your blow-off devices with EXAIR products like Super Air Knives, Super Air Nozzles, and Super Air Amplifiers, and save yourself even more money.  This blog is an overview of Step 2 of the Six Steps to Optimization. You may have more questions; and, that is great! You can find them in other EXAIR blogs, or you can contact an Application Engineer at EXAIR.

Jordan Shouse
Application Engineer

Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_JS

Air Leak Photo Courtesy of the Compressed air Challenge

Air Cooling Maintenance?

The time has finally come, and spring is here! The Cincinnati Reds are playing, Spring Soccer is happening early on Saturday mornings, and the FC Cincinnati Stadium is bustling here in Cincy. With that, temperatures are climbing, the grass and weeds are growing, and more and more families are out walking around and doing outdoor activities. With this, also comes warmer temps, and lots of spring allergies in the Farno household. As a dad, I have stepped into my role pretty well by trying to delay turning on the air conditioner until everyone else in the house is plotting my demise. This year, I achieved it by putting off the routine maintenance of the condensing coils.

In case you weren’t aware, here in the Midwest, where pollen runs rampant and the winds have been strong this year, it is a great idea to clean out the condensing coils on your home’s A/C system before turning it on for the year. Unfortunately, your home A/C system is not maintenance-free like the Cabinet Cooler Systems EXAIR offers; at the same time, your home needs a lot more than a few thousand BTU/hr of cooling capacity. When we first bought the home, I didn’t know this was a thing, as the home I grew up in didn’t have central air. We rocked Window A/Cs, and my parents still do. So, cleaning the outdoor unit was not part of my knowledge base. This is something I learned once the air conditioner wasn’t working, and I started to troubleshoot.

The main purpose of the condensing coils is to strip all the heat out of the refrigerant and get it to “condense” back into its liquid state to be pushed back through the orifice and continue to cool the air that is being passed over the A Coils inside the house. These coils are covered in fins that are very tightly spaced. The outside unit has a large fan that pulls the surrounding air in through the coils and exhausts the hot air up out of the top. There is no filter on that incoming ambient air, though, so all the leaves, cobwebs, pet hair, pollen, dirt, mulch, you name it, get pulled up into these fins. Over time, this starts to get a buildup, and the cooling fins will start to lose their efficiency. The fan won’t be able to pull as much air through, and eventually, the gas doesn’t get condensed, which then reduces the cooling and can cause other bigger issues. This is just like a refrigerant-based A/C panel cooler in a facility. Most of the time, they have at least a small filter on the air intake to try and reduce the contamination of the condensing coils. So I clean the A/C condenser at my house using a coil cleaning solution diluted down, a pump sprayer, and a regular garden hose.

The main thing to remember when cleaning this is that the majority of the dirt is from the air being pulled into the center by the fan. So I rinse the coils from the inside out and make sure I have free passage all the way through. The water doesn’t need to be a high-pressure rinse like an OmniStream nozzle or one of BETE’s NF Nozzles, just a simple low-pressure stream of water to get between the fins and push all contaminants as well as rinse the solution away. Remove any leaves or other unwanted debris from inside the unit and then bolt the fan and cage back down. Then let the family enjoy some cold air inside the house.

This type of maintenance is something that easily gets overlooked when looking at refrigerant-based electrical panel coolers. That is where EXAIR Cabinet Cooler Systems shine. The only filter you have to worry about is a redundant point-of-use compressed air filter that is included with the Cabinet Cooler Systems. No chemicals needed for cleaning, no water, no mess to change out a compressed air filter, just long-lasting performance. If you want to talk about how to change your control panels over to Cabinet Cooler Systems, contact an Application Engineer today.

Brian Farno, MBA – CCASS
National Business Development Manager

BrianFarno@EXAIR.com
@EXAIR_BF

Compressed Air Wet Receivers and Condensate Drains: Keeping your Systems Running Clean and Efficient

Compressed air systems are the backbone of countless industries and operations, from powering tools to cleaning, cooling and drying products in process. But behind the scenes, components like the wet receiver and condensate drain play pivotal roles in ensuring these systems deliver clean, reliable air. If you’re involved in facility management, maintenance, or just curious about how compressed air systems tick, understanding these elements can make all the difference. Let’s break it down!

What is a Wet Receiver in Compressed Air Systems?

In a compressed air setup, a receiver is a storage tank that holds pressurized air after it’s been compressed but before it’s distributed to the point of use. A wet receiver, specifically, is positioned downstream of the compressor but before the air dryer or major filtration stages. This means it stores “wet” compressed air—air that still contains moisture, oil, and other contaminants picked up during compression.

The “wet” designation comes from the fact that the air hasn’t been treated yet. As air is compressed, it heats up, and when it cools in the receiver, moisture condenses into liquid water. The wet receiver acts as a buffer, smoothing out pressure fluctuations and giving that moisture a place to settle before the compressed air moves further down the line. Think of it as a staging area that helps protect downstream equipment from surges and contaminants.

Condensate Drain

As air cools in the wet receiver, water vapor turns into liquid condensate—often mixed with traces of oil and dirt. If this condensate isn’t removed, it can corrode the receiver, clog pipes, or damage tools and equipment downstream. The condensate drain is the unsung hero that gets rid of this unwanted liquid.

Typically mounted at the bottom of the wet receiver , the drain can be manual, automatic, or timer-based:

  • Manual drains require someone to open a valve periodically.
  • Automatic float drains open when enough liquid accumulates.
  • Electronic timer drains release condensate at set intervals.

No matter the type, the goal is the same: keep the system dry and free of buildup.

A well-maintained wet receiver and condensate drain mean cleaner air, longer equipment life, and lower operating costs. Wet air can cut tool efficiency by 20% or more, while corrosion from neglected condensate can force early replacements for all downstream equipment. On the flip side, a little attention to these components keeps your compressed air system humming—and your bottom line happy.

Next time you hear the hiss of a pneumatic tool or the hum of a compressor, think about the wet receiver and condensate drain. They’re not flashy, but they’re indispensable.

Jordan Shouse
Application Engineer

Send me an Email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_JS

Photo: Blue Air Receiver Attribution – CC BY-ND 2.0