What’s So Great About The New EXAIR Catalog #35?

This may seem biased, but my answer is, “EVERYTHING!” Now, that may SEEM biased, but consider the fact that, as an Application Engineer, I have a front row seat for the “Innovation Show” that is EXAIR. The attention to detail that gets paid to the design, testing, verification, and manufacturing of new products constantly reminds me that it’s a level of excellence that EXAIR’s founder, Roy Sweeney, instilled and promoted in our culture from when he started this business in 1983, until his passing in 2016. It’s a testament to his legacy that, not only does it continue; it shows no signs of slowing down. It’s that level of excellence that’s always made it easy for me to speak with confidence about the quality, performance, durability, and effectiveness of all of EXAIR’s engineered compressed air products.

Our Marketing folks proudly passed out copies of the new EXAIR Catalog #35 the other day, and I immediately started immersing myself in that pride as I thumbed through. I thought of 12 years (for me) worth of success stories in helping customers get the most out of their compressed air systems through the use of our products, and our expertise in not only those products’ implementation, but how they can best fit into those customers’ air systems, overall. I wasn’t too far in to my thumbing through, when the “new stuff” really started making an impression on me:

Ultrasonic Leak Detector: Model 9207 is the first new product you’ll see if you start at the beginning. It has the same functionality and tools (parabolic disc for finding out you have leaks in a particular area, and a tubular extension so you can track the leak to its exact location), and some nice upgrades: it’s powered by four AA batteries (instead of a 9V) and comes with a set of earbuds (which I personally prefer over the previous model’s earphones, which I always considered a compromise between headphone & earbuds, with the benefits of neither). It’s never been easier to find those costly leaks in your air system, and fix them.


1/2 NPT HollowStream Liquid Atomizing Spray Nozzles: We’ve had these in 1/4 and 3/8 NPT sizes for a while now, with the ability to spray up to 7.28 gallons per minute. The 1/2 NPT models almost double that capacity to a flow rate of 14 gallons per minute. These spray a ring of liquid, so their flow rates are lower than a comparably sized Full Stream Liquid Atomizing Spray Nozzle, which spray a full, filled-in circle.


Line Vac Conveyance Chart: Remember what I said above about the ability to speak confidently about our products? This new chart compiles decades of controlled in-house testing and details that some customers have shared with us on the performance of different Line Vac models with different materials they’ve been used to convey. While we can’t guarantee EXACT conveyance performance for any specific application, this is a VERY handy tool to get us “in the ballpark” and further increases our great ability to specify the right Air Operated Conveyor for your application.


ATEX Cabinet Cooler Systems: It was a pretty big deal when we introduced our HazLoc Cabinet Cooler Systems that are UL Classified for Class I Div 1, Class II Div 1, and Class III environments. And it WAS a big deal, in the United States & Canada. Now, we can offer the certification of hazardous location requirements, globally, for ATEX Zones 2 & 22. That’s ANOTHER big deal.


Speaking of big deals, come October, EXAIR will have been providing quiet, safe, and efficient compressed air products to industry for 40 years. Catalog 35 has all the products that we’ve been making since then, and everything we’ve added over the years. Click here to get one mailed out to you right away. If you’ve got questions about anything in our catalog, or how EXAIR can help you get the most out of your compressed air system, give me a call.

Russ Bowman, CCASS

Application Engineer
Visit us on the Web
Follow me on Twitter
Like us on Facebook

NEMA/UL and IP ratings

From right to left: Small NEMA 12, Large NEMA 12, Large NEMA 4X

EXAIR manufactures Cabinet Coolers to keep your electrical components inside cool.  This will help to stop any costly shutdowns or premature electrical failures due to overheating.  The EXAIR Cabinet Cooler System is a simple device that generates cold air with no moving parts, condensers, or freon.  They are maintenance-free with a long-life cycle; and installation is quick and easy.  But when mounting the system to your electrical panel, you want to make sure that the Cabinet Cooler meets or exceeds the integrity standard for that environment.  There are standards that categorize electrical panels to protect workers, shield the environment, and contain the electrical components. 

Electrical panels come in all shapes, sizes and colors; and can be used in a variety of environments; indoor, outdoor, and even hazardous locations.  Depending on the place and setting, you will need to determine the minimum requirements for the integrity of your electrical panel.  For example, you do not want to use an โ€œindoor onlyโ€ electrical enclosure for outside areas.  Also, you would not want a standard enclosure to be used in a hazardous area, as it can be very dangerous.  The major organizations that create these electrical standards are NEMA, UL, and IP.  In this blog, I will cover these organizations and how they rate them.

NEMA, or National Electrical Manufacturer Association, and UL, or Underwriters Laboratory, are generally used in North America.  The difference between these two organizations is that the NEMA ratings are self-certifying while the UL requires testing by qualified inspectors, independent of the manufacturer, for compliance.  They use numbers and in some instances letters to indicate the type of environment that the enclosure can operate. EXAIR Cabinet Cooler Systems are UL listed; so, they have been tested and verified.  Currently, there are over 20 different NEMA/UL classifications.  Here is a description by WIKA that shows the different categories for both NEMA and IP.

IP, or Ingress Protection, is an international standard commonly used in Europe and is established by the International Electrotechnical Commission, or IEC.  This organization also allows for self-certification.  They use two digits to define levels of integrity for electrical enclosures against intrusion from foreign bodies and moisture. The first digit ranges from 1 to 6 which specifies the protection rating from solids.  The second digit, which ranges from 1 to 8, specifies the protection rating for ingress of water.  The higher the number, the better the protection.  The combination of these two numbers will give the protection level of the enclosure against dust and water.  There is an equivalence with the NEMA ratings to the IP ratings, but it is up to the preference of the user to verify the protection requirement. 

EXAIR offers three main NEMA types for our Cabinet Cooler Systems which are the most commonly found within facilities. We also offer an additional two types that are designated strictly for Hazardous Locations and are separately certified by UL to meet those standards.

NEMA 12

NEMA 12 (IP54) Cabinet Coolers are rated for dust tight and oil tight. NEMA 12 cabinet coolers are ideal for general industrial environments where no liquids or corrosives are present and are located inside.

NEMA 4

NEMA 4 (IP66) Cabinet Coolers are rated for dust tight, oil tight, splash resistant and indoor/outdoor service. These Cabinet Coolers incorporate a low-pressure relief valve to allow the internal hot air to escape as well as to close and seal when the cooler is not in operation.  This allows for this Cabinet Cooler to maintain the integrity of a NEMA 4 enclosure.

NEMA 4X

NEMA 4X (IP66) Cabinet Coolers offer the same protection as the NEMA 4 but are constructed of stainless steel for food service and corrosive environments.

HazLoc Cabinet Cooler Systems

HazLoc Cabinet Coolers are designed for hazardous locations and are mounted to NEMA 7, 8, and 9 enclosures.  EXAIR catalogs these Cabinet Coolers as NEMA 4 (IP66) or NEMA 4X (IP66) as mentioned above.  But their registration by UL classified is for Class I, Class II, and Class III hazardous areas.  The reason that they do not match the NEMA rating of the hazardous panels is because they require an X-type or Z-type purge system.  In combination, they will not sacrifice the integrity of hazardous electrical panels. 

EXAIR has Cabinet Coolers in stock with a variety of cooling capacities from 275 BTU/hr to 5,600 BTU/hr (69 Kcal/hr to 1,411 Kcal/hr).  We also offer them in 316SS, high temperature versions, and non-hazardous purge.  We do have a Cabinet Cooler System Calculator to help determine the best product for your application.  If you have any additional questions, an Application Engineer at EXAIR can assist you.   

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

The UL Classified Mark

Safety, itโ€™s a word that gets tossed around in both the work place and in your daily life.  From the beginning of time, people have been injuring themselves at work and at home. Today’s well known phrases “Hey watch this” or “Hold my Beer” became a popular way to say I am about to do something crazy and stupid and I know it. As someone who enjoys the outdoors and the thrills of extreme sports, I can attest from both personal experience and the experiences of those around me that people donโ€™t make smart decisions. At a young age I had a laundry list of injuries longer than most people 10 years older than me. But even in the craziest of my stunts (i.e. running an 18โ€™ waterfall in a kayak) there is a level of safety that is put into place. That safety can come from the practice it takes to develop higher skill (experience) or from the knowledge of experts around you. 

Companies have been trying to figure out ways to make offices and manufacturing plants a zero-incident environment for a long time. A lot of safety departments call this journey the Road to Zero and track each incident closely. Aside from policies and equipment modifications there are consulting and certification companies that focus solely on the safety of products used in manufacturing and production plants. One of the more prominent companies in the U.S. is UL or Underwriters Laboratories; this company was founded by an electrical engineer named William Henry Merrill in 1894. In 1893 an insurance company hired Merrill to perform a risk assessment on new potential clients, George Westinghouse and Nikola Tesla. This led him to realize the potential for an agency to test and set standards for product safety.

One example of a sought after and critical accreditation is the UL Classified Mark. The UL Classified certification means that the product has been evaluated, tested and passed the test for being safe when installed within classified areas. This includes a large range of hazardous locations which according to OSHA is defined as an explosive atmosphere due to the presence of flammable fluids (Class 1), combustible dusts (Class 2), or ignitable fibers and flyings (Class 3). These areas include everything from chemical plants to the food industry.

EXAIR’s Hazardous Location Cabinet Cooler

EXAIR has a Cabinet Cooler that can be used in these Hazardous Locations and earned the UL Classified Mark. The Hazardous Location Cabinet Cooler Systems are designed to be used with purged and pressurized systems in the following locations:

Class I Div 1, Groups A, B, C, and D
Class II Div 1, Groups E, F, and G
Class III

This means that the Hazardous Location Cabinet Coolers can be used in areas with explosive gas and vapors, combustible dusts, or ignitable fibers. 

If you have any questions about compressed air systems or want more information on any of EXAIR’s products, give us a call, we have a team of Application Engineers ready to answer your questions and recommend a solution for your applications.

Cody Biehle
Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook

Hazardous Location Cabinetย Coolers

Last year was a big year for EXAIRโ€™s Cabinet Cooling product line, in Novemberย  we launched our first Hazardous Location Cabinet Coolers!ย  EXAIR has always been a leading supplier in compressed air-based Cabinet Coolers, now we have expanded on that to work in the most high-risk conditions.

When a Hazardous Location Cabinet Cooler is used in conjunction with a purge system, they will keep electrical equipment at the desired operating temperature to protect and lengthen the lifetime of pricey controls and power supplies.

hazloc_illLsr-800w
Hazardous Location Cabinet Cooler

 

Electrical equipment can cause explosions in certain atmospheres. Equipment used in areas where explosive concentrations of dusts or vapors may exist must be equipped with special wiring and other electrical components for safety purposes. Hazardous (classified) locations such as these might exist in aircraft hangars, gasoline stations, paint-finishing locations or grain bins. EXAIRโ€™s Hazardous Location Cabinet Coolers have been approved and tested by UL for use in the following areas:

classified_cULus_360x283
UL Approved and Tested

Class I Div 1&2 โ€“ Groups A, B, C, and D

  • Class I Areas refer to the presence of flammable gases or vapors in quantities sufficient to produce explosive or ignitable mixtures. Class I Div 1 will have ignitable concentrations of flammable gases present during the course of normal operations. This is level of approval is one that differentiates the EXAIR Hazardous Location Cabinet Coolers from much of the competition. Class 1 Div 2 areas will have flammable gasses or vapors present only in the event of an accident or during unusual operating conditions.

Class II Div 1&2 โ€“ Groups E, F, and G

  • Class II areas are locations in which combustible dust may exist. The end user shall avoid installation of the device in a Class II environment where dust may be readily disturbed from the exhausts of the Hazardous Location Cabinet Cooler. Any dust formed in the vicinity of the cooler must be cleaned regularly.

Class III

  • Class III areas are locations that will have ignitable fibers or flyings present. This is common within the textile industry.

The Cabinet Cooler also carries a temperature rating of T3C, meaning it cannot be installed near any materials that could auto-ignite at temperatures in excess of 320ยฐF.

The Hazardous Location Cabinet Cooler is available in (8) different cooling capacities ranging from 1,000 Btu/hr โ€“ 5,600 Btu/hr. The Cabinet Cooler is the best solution for protecting your sensitive electronics from heat, dirt, and moisture. With Nema 4/4X systems available, theย Hazardous Location Cabinet Coolersย will keep the cabinet cool without compromising the integrity of the enclosure.

If youโ€™ve got an electrical cabinet installed within a hazardous location, fill out theย Cabinet Cooler Sizing Guideย and allow anย EXAIR Application Engineerย to determine the most suitable model for you.

Jordan Shouse
Application Engineer
Send me anย email
Find us onย the Webย 
Like us onย Facebook
Twitter:ย @EXAIR_JS