OSHA At 35,000 Feet

Early one morning I was on a flight to the West coast to start up a system that I had designed and built for a large food producer.  After the flight attendants had passed out our first beverage and snack I struck up a conversation with the passenger next to me.  We engaged in the typical banter about how hilarious it is to watch some passengers try to stuff an oversized bag into the overhead compartment and ultimately have to check it.

I then asked the reason for her trip and she explained that she worked for OSHA and had conducted a study on flight crew safety and was in route to give her report on the findings.  I was naturally intrigued and asked her what the risks were for a flight crew other than the obvious perils of being 35,000 Ft. above the ground for long periods of time.

Her reply was radiation exposure from the sun!  I had never considered that flight crews spend long periods of time above the thickest layer of our atmosphere.  Flight crews are exposed to significantly greater amounts of radiation compared to us folks who are on the ground more and consequently develop certain health conditions at a higher rate than the general population.

While EXAIR can’t help you with radiation exposure, we can bring you into OSHA compliance with noise, OSHA Standard 29 CFR – 1910.95 (a).

This standard is concerned with the level of noise that personnel are exposed to over a given period of time.  Often times in plants compressed air noise exceeds the OSHA noise level requirements which unfortunately results in hearing loss.  Noisy air blow-offs can produce noise in excess of 100 dBA.  Studies have proven that noise levels that are sustained for varying periods of time can ultimately result in permanent hearing loss.  Similar to the way flight crews are exposed to the radiation, some employess may not realize they are being exposed to a harmful level of noise from compressed air usage.  This is why OSHA generated the standard that has allowable limits for sustained noise levels in order to mitigate the risks for personnel in the area.  Utilizing EXAIR Super Air Nozzles the noise can be reduced to only 74 dBA.  EXAIR Engineered Air Nozzles reduce the noise without losing the hard hitting force.

dBA Chart

EXAIR also meets OSHA Standard 29 CFR 1910.242(b) for “Dead End Pressure”. This standard addresses how dangerous compressed air can be when the outlet pressure of a hole, hose or open pipe is higher than 30 PSIG (2 Bar).  If the opening is blocked (dead-ended) into any part of the body, air could enter the bloodstream through the skin.  This may result in serious injury.  All EXAIR Nozzles and Jets are designed for safety and can’t be dead-ended into the skin therefore can be safely operated above the 30 PSIG (2 Bar) limit.

sag-osha-compliant

If you would like to discuss noise levels, dead end pressure or any of EXAIR’s engineered solutions, I would enjoy hearing from you…give me a call.

Steve Harrison
Application Engineer
Send me an email
Find us on the Web 
Follow me on Twitter
Like us on Facebook

Small, Precise Blowoff at Your Fingertips

For many blowoff applications, stronger isn’t necessarily better.  For applications and processes where a light, but effective blast of air is needed for cleaning and drying, the VariBlast Compact Safety Air Gun with the Atto, Pico, or Nano nozzle fits the bill. The smallest of the EXAIR engineered Super Air Nozzle family, the Atto, Pico, and Nano have been designed to provide the smallest, most precise blowoff possible. The focused airflow pattern allows for very accurate control and placement of the air stream.  The nozzles are available in both Type 316 Stainless Steel and PEEK plastic (useful for harsh environments, and is non-marring)

img_7480.jpg
The Atto, Pico, and Nano Super Air Nozzles (Scale is in Inches)

The new VariBlast Compact Safety Air Gun is a great choice for putting the power and performance of the nozzle into a small and lightweight air gun. Designed with a variable flow trigger, the airflow can be throttled from a whisper to full force, simply by varying the trigger pull distance.

1698SS
VariBlast Model 1698SS, with Stainless Steel Nano Super Air Nozzle

The Atto, Pico, and Nano nozzles use very little compressed air and are extremely quiet, easily meeting OSHA Standard 29 CFR 1910.95(a) for Noise Exposure.  The design incorporates engineered solutions for safety and can be supplied with higher pressure compressed air and meet OSHA Standard 29 CFR 1910.242(b), relating to dead end pressure requirements.

The table below provides performance data, including the compressed air consumption, force, and sound level for the various configurations.

VariBlast With Small Nozzles

Note that the VariBlast air guns can be had with extensions from 6″ to 72″ and chip shields to meet the performance and safety needs of any application.

The Atto, Pico and Nano Nozzles can also be configured to work with the Soft Grip style of Safety Air Gun.  Consult an Application Engineer for assistance in choosing.

If you have any questions about the Atto, Pico, or Nano nozzles, the VariBlast Compact Safety Air Gun, or any EXAIR compressed air product, feel free to contact EXAIR and myself or one of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer

Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

Digital Sound Level Meter Identifies Harmful Noise in the Workplace

slm-newlabel EXAIR offers the model 9104 Digital Sound Level Meter.  It is an easy to use instrument for measuring and monitoring the sound level pressures in and around equipment and other manufacturing processes.

Sound meters convert the movement of a thin membrane due to the pressure waves of sound into an electric signal that is processed and turned into a readable output, typically in dBA.  The dBA scale is the weighted scale that most closely matches the human ear in terms of the sounds and frequencies that can be detected.

 

To protect workers in the workplace from suffering hearing loss OSHA has set limits to the time of exposure based on the sound level.  The information in the OSHA Standard 29 CFR – 1910.95(a) is summarized below.

OSHA Noise Level

The Digital Sound Meter can be used to monitor and measure sound levels of manufacturing processed such as blowoffs for cooling or drying.  Many blowoffs, especially open or drilled pipes are very inefficient and can be identified as a source of excessive noise, outside the OSHA exposure ranges.  Once the noise violators are identified, a review can be done and the implementation of engineered solutions such as Super air Nozzles or Super Air Knives can be investigated. Keeping harmful noise levels in check benefits everyone involved.

The EXAIR Digital Sound Level Meter is an accurate and responsive instrument that measures the decibel level of the sound and displays the result on the large optionally back-lit LCD display. There is an “F/S” option to provide measurement in either ‘slow’ or ‘fast’ modes for stable or quickly varying noises. The ‘Max Hold’ function will capture and hold the maximum sound level, and update if a louder sound occurs.

Certification of accuracy and calibration traceable to NIST (National Institute of Standards and Technology) is included.

There is an informative Video Blog, presented by @EXAIR_LE that can be found here.

If you have questions about the Digital Sound Level Meter, or would like to talk about any of the quiet EXAIR Intelligent Compressed Air® Products, feel free to contact EXAIR and myself or one of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer

Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

OSHA 29 CFR 1910.95 – Standard on Occupational Noise Exposure

Last week, the EXAIR Blog featured an article about the OSHA Standard 1910.242(b) – Reduction of Air Pressure below 30 psi for Cleaning Purposes.  This week, we will review another OSHA standard that affects many of you in manufacturing and other industries.

OSHA 29 CFR 1910.95 – Standard on Occupational Noise Exposure discusses the effects of noise and sets limits for exposure.  Occupational noise can cause hearing loss, and also interfere with concentration and communication, disrupting the job performance. Below is a summary from the standard of the Permissible Noise Exposure (OSHA Table G-16)

OSHA Noise Level

From the chart, the time an employee can be exposed to loud noise is greatly reduced as the sound level goes up.   The use of hearing protection is helpful but relies on the operator to use consistently and correctly.  Ear plugs or ear muffs can be uncomfortable and hot, leading to possible reduced usage.  OSHA can come on site, and if violations to the sound level exposure limits are found, they can impose fines and mandate corrective action be taken place.

The recommended course of action when an operator is subjected to sound exceeding those in the chart above is to enable feasible administrative or engineering controls. Engineering controls is the arena in which EXAIR can be a great resource.

The first step in understanding and addressing any sound level issues is to measure the sound. The easy to use Digital Sound Meter, model 9104 shown below, allows for accurate testing of noise levels throughout the facility.  Noisy areas can be quickly identified, leading to review, design and implementation of the engineering controls.

SoundMeter_new_nist225

Some of the worst offenders for noise violations is compressed air usage.  A prime example would be inefficient blowoffs, used for cooling, drying, or cleaning.  Open pipe, copper tube or drilled pipe are a few of the common culprits.  Not only do they consume excessive amounts of compressed air, they can produce noise levels above 100 dBA.

EXAIR manufactures a wide variety of engineered products that utilize compressed air and deliver it in a controlled manner.  This allows for the most efficient use of compressed air and keeps the sound levels much lower than the inefficient methods.  A Super Air Knife can replace a drilled pipe, reducing sound by as much as 20 dBA, while using 50-70% less compressed air.  An engineered Super Air Nozzle can replace an open pipe or copper tube and reduce sound levels down to 74 dBA, and even down to 58 dBA for the smallest available nozzles.

EXAIR has been providing Intelligent Compressed Air Products since 1983.

If you have questions regarding noise limits and how to solve any issue with an EXAIR Intelligent Compressed Air® Product, feel free to contact EXAIR and myself or one of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer

Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

 

EXAIR Leads the Way with Standards and Certifications

For over 34 years, EXAIR has been the industry leader in providing Intelligent Compressed Air Products to the industrial marketplace. While much of our focus is to ensure our products are engineered to provide optimal performance, we are also dedicated to manufacturing products that meet a wide range of standards and directives to promote safety in relation to plant personnel.

 

For instance, all of our compressed air operated products meet or exceed OSHA Standards 29 CFR 1910.242(b), requiring that the outlet pressure of an open pipe, nozzle, air gun, etc., when used for cleaning purposes, must remain below 30 PSI when dead-ended against the skin, as well as Standard 29 CFR 1910.95(a) as a way to protect workers from job related injuries related to dangerous sound levels of 90 dBA and higher.

 

 


Many of our products are also CE Compliant, meeting the mandatory requirements for products intended to be sold in the European Economic Area or “EEA”. For example our Electronic Flow Control and Electronic Temperature Control (ETC) meet the EU (European Union) Low Voltage Directive 2006/95/EC.

 

 

EXAIR electrically powered devices, like our Static Eliminators and Digital Flowmeters for example, comply with the “Restriction of Hazardous Substances” or RoHS Directive 2011/65/EU, including the amendment outlined in the European Commission decision L 214/65.

 

 

We are also committed to providing material that supports the conflict mineral free rule to help aid in the relief of illegal trade of exotic materials, like tungsten, gold, tin and tantalum in the DRC region. Using the CMRT 4.20 template, we document our supply resources to ensure we provide conflict free products, as outlined in Section 1502 of the Dodd-Frank Wall Street Reform and Consumer Protection Act.

 

Lastly, the European Union introduced the REACH program – Registration, Evaluation, Authorization and Restriction of Chemicals, as a method to register chemical substances being imported into the EU to protect people and the environment, per Regulation (EC) No 1907/2006 Title I, Article 3.  Also noted in the program, Title II, Article 7, they state that any product with a substance intended to be released under normal operating conditions, must be registered for quantities totaling more than 1 metric ton per year. Since EXAIR products do not intentionally release or contain any such substances, registration to meet the program is not required.

 

If you have any questions about any of these Standards or Directives or about which EXAIR products comply, please feel free to contact an application engineer for assistance. We’d be happy to help!

Justin Nicholl
Application Engineer
justinnicholl@exair.com
@EXAIR_JN

Engineered Air Nozzles Reduce Noise Levels and Outlet Pressure, Meeting OSHA Requirements

“My operators are complaining that our air guns are too loud, how can you help me?” – is a very common inquiry we receive here at EXAIR on almost a daily basis. Many open end blowoffs or air guns fitted with nozzles that have cross drilled relief holes create high pitch wind shear, resulting in excessive noise levels, sometimes exceeding 100+ dBA. This not only is a safety concern but also an OSHA violation.

Variety of Air Nozzles that produce dangerously loud noise levels

Loud noises and the length of exposure time can lead to significant health concerns such as long term hearing loss, increased stress levels and potential injury due to lack of concentration. The Occupation Safety and Health Administration (OSHA) introduced Standard 29 CFR 1910.95(a) as a way to protect workers from job related injuries associated to potentially dangerous sound levels. Per the Standard, at 90 dBA an operator is limited to a maximum of 8 hours of constant exposure. As noise levels increase, the allowable exposure time decreases, in some cases slowing production, costing a company on their bottom line.

 

EXAIR’s Air Nozzles are engineered so they entrain surrounding air across the profile of the nozzle, which produces a smoother airflow, ultimately reducing wind shear, resulting in much lower sound levels, meeting the OSHA Standard.

Illustration showing the air travel of our Super Air Nozzles

 

In addition, our Air Nozzles also meet the OSHA Standard 1910.242(b) for 30 PSI dead end pressure. All of our engineered Air Nozzles provide a relief or a safe path for the air to exit if the nozzle were to be blocked or pressed against an operator’s body so the exiting air pressure will never reach 30 PSIG.

All of EXAIR’s Air Nozzles are available with standard NPT threads to easily adapt to existing air guns. We also off our full line of Safety Air Guns which are fitted with our engineered nozzles, providing an “off-the-shelf” OSHA compliant solution. For help selecting the best product to replace your existing device or if you have a new application you would like to discuss, give us a call at 800-903-9247.

Justin Nicholl
Application Engineer
justinicholl@exair.com
@EXAIR_JN

 

Explanation of OSHA Standard 1910.242(b)

Open air lines and homemade blow offs violate OSHA standard 1910.242(b) because of harmful dead end pressures. In 1972, OSHA established Standard 29 CFR 1910.242(b) requiring that the outlet pressure of an open pipe, nozzle, air gun, etc., when used for cleaning purposes, must remain below 30 PSI with the intent to protect workers from serious injury. They determined that when dead-ended against the skin, if the outlet pressure reached 30 PSI 0r higher,  it posed a risk of entering the bloodstream through the skin. This is commonly referred to as an air embolism – a serious condition which can be life threatening. Once air has entered the bloodstream, it can restrict the free movement of blood throughout the body, disrupting normal heart function, leading to abnormal heart rhythm, possible lung or brain damage, cardiac arrest, stroke or possible death.

OSHA explains that you can use compressed air for cleaning purposes, as long as the outlet or source is fitted with some type of relief device that drops the outlet pressure to below 30 PSI if dead ended. There are basically two ways to go about gaining compliance. The first is to regulate the operating supply pressure to less than 30 PSI, assuring that the outlet pressure doesn’t exceed the threshold. While this does comply with the Standard, it can negatively affect the performance by reducing the strength of the outlet flow, limiting the usefulness of the blowoff device.

The other method is to use some type of nozzle which includes a pressure reducer or a relief device which will reduce the air pressure to less than 30 PSI if the nozzle is dead ended.

For example, EXAIR engineered air nozzles are designed so the outlet holes cannot be blocked directly. Any potential obstruction of the outlet air holes results in the air having an alternative exit path to avoid injury to operators and personnel.

sag-osha-compliant
With our Super Air Nozzles, the air exits through a series of jets, recessed behind an array fins so the exhausting airflow can never be blocked.

With the design of our Super Air Knife, the cap overlaps the body, leaving a gap on both sides of the knife, allowing the exhausting air to safely vent.

osha-sak
Picture of the Super Air Knife, showing how the cap overlaps the body and cannot be blocked, providing a safe exit path.

ALL of EXAIR‘s engineered products incorporate these principles, providing some type of relief, allowing for the air to safely vent well below the 30 PSI requirement, meeting and in many cases, exceeding the OSHA Standard.

To discuss how EXAIR can help you gain OSHA compliance to improve operator safety, avoid costly fines and improve overall efficiency, contact an application engineer for assistance.

Justin Nicholl
Application Engineer
justinnicholl@exair.com