Estimating the Cost of Compressed Air Systems Leaks

Leaks in a compressed air system can waste thousands of dollars of electricity per year. In fact, in many plants, the leakage can account for up to 30% of the total operational cost of the compressor. Some of the most common areas where you might find a leak would be at connection joints like valves, unions, couplings, fittings, etc. This not only wastes energy but it can also cause the compressed air system to lose pressure which reduces the end use product’s performance, like an air operated actuator being unable to close a valve, for instance.

One way to estimate how much leakage a system has is to turn off all of the point-of-use devices / pneumatic tools, then start the compressor and record the average time it takes for the compressor to cycle on and off. The total percentage of leakage can be calculated as follows:

Percentage = [(T x 100) / (T + t)]

T = on time in minutes
t = off time in minutes

The percentage of compressor capacity that is lost should be under 10% for a system that is properly maintained.

Another method to calculate the amount of leakage in a system is by using a downstream pressure gauge from a receiver tank. You would need to know the total volume in the system at this point though to accurately estimate the leakage. As the compressor starts to cycle on,  you want to allow the system to reach the nominal operating pressure for the process and record the length of time it takes for the pressure to drop to a lower level. As stated above, any leakage more than 10% shows that improvements could be made in the system.

Formula:

(V x (P1 – P2) / T x 14.7) x 1.25

V= Volumetric Flow (CFM)
P1 = Operating Pressure (PSIG)
P2 =  Lower Pressure (PSIG)
T = Time (minutes)
14.7 = Atmospheric Pressure
1.25 = correction factor to figure the amount of leakage as the pressure drops in the system

Now that we’ve covered how to estimate the amount of leakage there might be in a system, we can now look at the cost of a leak. For this example, we will consider a leak point to be the equivalent to a 1/16″ diameter hole.

A 1/16″ diameter hole is going to flow close to 3.8 SCFM @ 80 PSIG supply pressure. An industrial sized air compressor uses about 1 horsepower of energy to make roughly 4 SCFM of compressed air. Many plants know their actual energy costs but if not, a reasonable average to use is $0.25/1,000 SCF generated.

Calculation :

3.8 SCFM (consumed) x 60 minutes x $ 0.25 divided by 1,000 SCF

= $ 0.06 per hour
= $ 0.48 per 8 hour work shift
= $ 2.40 per 5-day work week
= $ 124.80 per year (based on 52 weeks)

As you can see, that’s a lot of money and energy being lost to just one small leak. More than likely, this wouldn’t be the only leak in the system so it wouldn’t take long for the cost to quickly add up for several leaks of this size.

If you’d like to discuss how EXAIR products can help identify and locate costly leaks in your compressed air system, please contact one of our application engineers at 800-903-9247.

Justin Nicholl
Application Engineer
justinnicholl@exair.com
@EXAIR_JN

 

 

 

 

 

Video Blog: Applying PTFE Tape to Compressed Air Fittings

This video illustrates the proper way to apply PTFE (Teflon*, or Plumber’s) tape to a threaded fitting in order to eliminate future problems with your compressed air system or products.

*Teflon is a registered trademark of E.I. Du Pont de Nemours and Company Corporation.

Have a Good Day,
John Ball, Application Engineer
1-800-903-9247
johnball@exair.com
@EXAIR_JB

3 Common Mistakes in Your Compressed Air System

Every day I speak with engineers who are having trouble using compressed air products. A common problem they have is not providing an adequate air supply to their unit. I go through a basic troubleshooting technique to ensure that their pressure and flow rate is adequate. I ask them to install tee on the inlet to the compressed air product in order to install a pressure gauge right at the inlet to the pipe. This allows us to know exactly what pressure we are supplying to the product. Customers are always surprised how the gauge on the compressor or the regulator may read 120 PSIG, but the gage on the inlet to the compressed air product is significantly less.

Last year, my colleague, Russell Bowman, made an excellent video showing how the inlet pressure at the knife will have a significant impact on the performance of the Super Air Knife.  In the video, he changes the length and ID of the compressed air supply to illustrate the difference a proper supply line will have on the performance of a compressed air products.

Not providing adequate air supply is commonly caused by these three mistakes, when plumbing compressed air systems.

1. Incorrectly Sized Piping – This can be the single biggest problem. A lack of planning before installing a compressed air product. Not all compressed air systems are created equal. Though a 1/4″ shop air hose may work for a number our products, some of our products require a larger air line because they require more volume of air to be effective. We often speak with customers an illustrate this problem by stating small air lines are like trying to feed a fire hose with a garden hose – there simply is not enough volume to create the pressure necessary to reach the fire, or solve the application in our scenarios. We publish the flow rates for all of our products and make inlet pipe size recommendation in the installation and maintenance guide furnish with the products so you may avoid this common problem. We also have air data tables in our Knowledge Base or  you may consult an application engineer who will be happy to make the proper recommendation.

2. Quick Disconnects – These handy connectors are great when operating a brad nailer, or a small blow gun, but the small through diameter can severely limit the flow rate into a long air knife, large diameter air operated conveyor, or big vortex tubes.  Due to this fact it is strongly advised to use threaded fittings or over-sized quick disconnects.

3. Adding extra hose or pipe – Extra hose is never a bad thing, right? No, an extra 30 feet of air hose can significantly drop the pressure of a compressed air system. 20 feet of ½ Pipe can flow 70 CFM with a 5 PSI pressure drop.  50 feet of ½” pipe will only flow 42 SCFM with the same 5 PSIG pressure drop. Keep your hose or pipe lengths to a minimum to improve the volume of air you can deliver to a compressed air product.

Dave Woerner
Application Engineer
DaveWoerner@EXAIR.com
@EXAIR_DW