Supply Side Review: Deliquescent Type Dryers

As mentioned in my post last week.  The supply side of compressed air systems within a facility is critical to production.  The quality of air produced by your compressor and sent to the demand side of the system needs to be filtered for both moisture and particulate.  One method to dry the air, that is the topic for this blog, is deliquescent type dryers.

These dryers operate like an adsorbent dryer such as a desiccant medium dryer.  The main variance is that the drying medium (desiccant) actually undergoes a phase change from solids to liquids.  Because of this the material is used up and cannot be returned to its original state for reuse.   The liquids formed by the desiccant dissolving in the removed water vapor are then filtered out of the air stream before it is passed on to the demand side of the air system.

There are many compounds that are used to absorb the moisture in the wet compressed air.  A few options are potassium, calcium, or sodium salts and many that contain a urea base.  The desiccant compound must be maintained at a minimum level for the dryer to contain enough media to successfully dry the air.

These dryers are generally a single tank system that is fed with compressed air from a side port near the bottom of the tank.  The air then travels up past drip trays where the desiccant and water mixture fall and ultimately ends up in the bottom of the tank.  The air then goes through a material bed that must be kept at a given level in order to correctly absorb the moisture in the air.  The dry air is then pushed out the top of the tank.

As the desiccant material absorbs the liquid from the compressed air flowing through the tank it falls onto the drip trays and then into the bottom of the tank where it is drained out of the system.  This process can be seen in the image below.

 

Deliquescent type compressed air drying system
How a deliquescent air dryer works – 1(VMAC Air Innovated, 2017)

 

The dew point that this style dryer is able to achieve is dependent on several variables:

  • Compressed air temperature
  • Compressed air pressure / velocity
  • Size and configuration of the tank
  • Compression of the absorption media
  • Type of absorption media and age of media

These dryers are simplistic in their design because there are no moving parts as well as easy to install and carry a low startup cost.

Some disadvantages include:

  • Dewpoint range 20°F – 30°F (Again this is according to the media used.)
  • Dissolved absorption material can pose a disposal issue as it may not be able to be simply put down a drain
  • Replacement of the absorption material

Even with disadvantages the ability to supply the demand side of a compressed air system for a production facility is key to maintaining successful operations.  If you would like to discuss any type of compressed air dryer, please contact us.

Brian Farno
Application Engineer
BrianFarno@EXAIR.com
@EXAIR_BF

 

1 – Deliquescent Dryer Image: VMAC Air Innovated: The Deliquescent Dryer – https://www.vmacair.com/blog/the-deliquescent-dryer/

 

Intelligent Compressed Air: Membrane Dryers

A critical component on the supply side of your compressor system is the dryer. Atmospheric air contained within a compressed air system contains water vapor. The higher the temperature of the air, the more volume of moisture that air is capable of holding. As air is cooled, this water vapor can no longer be contained and this water falls out in the form of condensation. The temperature where this water will drop out is referred to as the dew point.

At a temperature of 75°F and 75% relative humidity, approximately 20 gallons of water will enter a 25HP compressor during a 24-hour period. As air is compressed, this water becomes concentrated. Since it’s heated during the compression process, this water stays in a vapor form. When this air cools further downstream, this vapor condenses into droplet form.

Moisture within the compressed air system can result in rust forming on the inside of the distribution piping, process failure due to clogged frozen lines in colder weather, false readings from instruments and controls, as well as issues with the point of use products installed within the system.

The solution to this problem is to install a dryer system. We’ve spent some time here on the EXAIR blog reviewing refrigerant dryers , desiccant dryers, deliquescent dryers, and heat of compression dryers. For the purposes of this blog, I’m going to focus on one of the newer styles on the market today: the membrane dryer.

Membrane Dryer

In a membrane dryer, compressed air is forced through a specially designed membrane that permits water vapor to pass through faster than the air. The water vapor is then purged along with a small amount of air while the rest of the compressed air passes through downstream. Generally, the dew point after the membrane dryer is reduced to about 40°F with even lower dew points also possible down to as low as -40°F!

With such low dew points possible, it makes a membrane dryer an optimal choice in outdoor applications that are susceptible to frost in colder climates. Membrane dryers also are able to be used in medical and dental applications where consistent reliability is critical.

A membrane dryer does not require a source of electricity in order to operate. The compact size makes it simple to install without requiring a lot of downtime and floor space. Since they have no moving parts, maintenance needed is minimal. Most often, this maintenance takes the form of checking/replacing filter elements just upstream of the membrane dryer. The membrane itself does need to be periodically replaced, an indicator on the membrane dryer will display when it needs to be changed. If particular instruments or processes in your facility are sensitive to moisture, a membrane dryer might be the best option.

However, there are some drawbacks to these types of dryers. They’re limited to low capacity installations, with models ranging from less than 1 SCFM up to 200 SCFM. This makes them more applicable for point-of-use installations than for an entire compressed air system. The nature in which the membrane dryer works necessitates some of the air to be purged out of the system along with the moisture. To achieve dew points as low as -40°F, this can equate to as much as 20% of the total airflow. When proper filtration isn’t installed upstream, oils and lubricants can ruin the dryer membrane and require premature replacement.

Make sure and ask plenty of questions of your compressor supplier during installation and maintenance of your system so you’re aware of the options out there. You’ll of course want to make sure that you’re using this air efficiently. For that, EXAIR’s wide range of engineered Intelligent Compressed Air Products fit the bill. With a variety of products available for same-day shipment from stock, we’ve got you covered.

Tyler Daniel
Application Engineer
E-mail: TylerDaniel@EXAIR.com
Twitter: @EXAIR_TD

 

Membrane Dryer Schematic – From Compressed Air Challenge, Best Practices for Compressed Air Systems, Second Edition

 

Supply Side Review: Heat of Compression-Type Dryers

The supply side of a compressed air system has many critical parts that factor in to how well the system operates and how easily it can be maintained.   Dryers for the compressed air play a key role within the supply side are available in many form factors and fitments.  Today we will discuss heat of compression-type dryers.

Heat of compression-type dryer- Twin Tower Version

Heat of compression-type dryers are a regenerative desiccant dryer that take the heat from the act of compression to regenerate the desiccant.  By using this cycle they are grouped as a heat reactivated dryer rather than membrane technology, deliquescent type, or refrigerant type dryers.   They are also manufactured into two separate types.

The single vessel-type heat of compression-type dryer offers a no cycling action in order to provide continuous drying of throughput air.  The drying process is performed within a single pressure vessel with a rotating desiccant drum.  The vessel is divided into two air streams, one is a portion of air taken straight off the hot air exhaust from the air compressor which is used to provide the heat to dry the desiccant. The second air stream is the remainder of the air compressor output after it has been processed through the after-cooler. This same air stream passes through the drying section within the rotating desiccant drum where the air is then dried.  The hot air stream that was used for regeneration passes through a cooler just before it gets reintroduced to the main air stream all before entering the desiccant bed.  The air exits from the desiccant bed and is passed on to the next point in the supply side before distribution to the demand side of the system.

The  twin tower heat of compression-type dryer operates on the same theory and has a slightly different process.  This system divides the air process into two separate towers.  There is a saturated tower (vessel) that holds all of the desiccant.  This desiccant is regenerated by all of the hot air leaving the compressor discharge.  The total flow of compressed air then flows through an after-cooler before entering the second tower (vessel) which dries the air and then passes the air flow to the next stage within the supply side to then be distributed to the demand side of the system.

The heat of compression-type dryers do require a large amount of heat and escalated temperatures in order to successfully perform the regeneration of the desiccant.  Due to this they are mainly observed being used on systems which are based on a lubricant-free rotary screw compressor or a centrifugal compressor.

No matter the type of dryer your system has in place, EXAIR still recommends to place a redundant point of use filter on the demand side of the system.  This helps to reduce contamination from piping, collection during dryer down time, and acts as a fail safe to protect your process.  If you would like to discuss supply side or demand side factors of your compressed air system please contact us.

Brian Farno
Application Engineer
BrianFarno@EXAIR.com
@EXAIR_BF

 

Heat of compression image: Compressed Air Challenge: Drive down your energy costs with heat of compression recovery: https://www.plantservices.com/articles/2013/03-heat-of-compression-recovery/

 

About Compressed Air Dryers – What Are They and Why Use Them

All atmospheric air contains some amount of water vapor.  When air is then cooled to saturation point, the vapor will begin to condense into liquid water. The saturation point is the condition where the the air can hold no more water vapor. The temperature at which this occurs is knows as the dew point.

When ambient air is compressed, heat is generated and the air becomes warmer. In industrial compressed air systems, the air is then routed to an aftercooler, and condensation  begins to take place. To remove the condensation, the air then goes into separator which traps the liquid water. The air leaving the aftercooler is typically saturated at the temperature of the discharge, and any additional cooling that occurs as the air is piped further downstream will cause more liquid to condense out of the air. To address this condensation, compressed air dryers are used.

It is important to dry the air and prevent condensation in the air. Many usages of the compressed air are impacted by liquid water being present. Rust and corrosion can occur in the compressed air piping, leading to scale and contamination at point -of -use processes. Processes such as drying operations and painting would see lower quality if water was deposited onto the parts.

dryers.png

There are many types of dryers – (see recent blogs for more information)

  • Refrigerant Dryer – most commonly used type, air is cooled in an air-to-refrigerant heat exchanger.
  • Regenerative-Desiccant Type – use a porous desiccant that adsorbs (adsorb means the moisture adheres to the desiccant, the desiccant does not change, and the moisture can then be driven off during a regeneration process).
  • Deliquescent Type – use a hygroscopic desiccant medium that absorbs (as opposed to adsorbs) moisture. The desiccant is dissolved into the liquid that is drawn out. Desiccant is used up, and needs to be replaced periodically.
  • Heat of Compression Type – are regenerative desiccant dryers that use the heat generated during compression to accomplish the desiccant regeneration.
  • Membrane Type– use special membranes that allow the water vapor to pass through faster than the dry air, reducing the amount water vapor in air stream.

The air should not be dried any more than is needed for the most stringent application, to reduce the costs associated with the drying process. A pressure dew point of 35°F to 38°F (1.7°C to 3.3°C) often is adequate for many industrial applications.  Lower dew points result in higher operating costs.

If you have questions about compressed air systems and dryers or any of the 15 different EXAIR Intelligent Compressed Air® Product lines, feel free to contact EXAIR and myself or any of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB