What is a Decibel Level?

Decibel level also known as dBA, is how the industry measures sound intensity’s effect on the human ear and is an important value when discussing noise exposure for employees and operators within manufacturing. Manufacturing personnel can be at risk for hearing damage when exposed to high decibel levels if the proper precautions are not taken. For reference, 0 dBA is the softest level that a person can hear. Normal speaking voices are around 65 dBA. A rock concert can be about 120 dBA.

Sounds that are 85 dBA or above can permanently damage your ears. The more sound pressure a sound has, the less time it takes to cause damage. This damage occurs within a sensitive part of our ear called the cochlea, which contain thousands of hair cells used to allow our brains to detect sounds. For example, a sound at 85 dBA may take as long at 8 hours to cause permanent damage, while a sound at 100 dBA can start damaging hair cells after only 30 minutes of listening.

OSHA Max Noise Exposure Chart

The Center for Disease Control (CDC) estimates that 22 million workers are exposed to potentially damaging noise at work each year. Whether you work near machinery, at a sports venue, on a tarmac, or operate a jackhammer—hearing loss is preventable.

Noise may be a problem in your workplace if you:

  • Hear ringing or humming in your ears when you leave work.
  • Have to shout to be heard by a coworker an arm’s length away.
  • Experience temporary hearing loss when leaving work.

If you need to raise your voice to speak to someone 3 feet away, noise levels might be over 85 decibels. Sound-measuring instruments are available to measure the noise levels in a workspace.

The first step to lowering your sound level is to take a baseline reading of your various processes and devices that are causing the noise. EXAIR’s Sound Level Meter, Model 9104, is an easy to use instrument that provides a digital readout of the sound level. They come with an NIST traceable calibration certificate and will allow you to determine what processes and areas are causing the most trouble.

From there, EXAIR has a wide range of Intelligent Compressed Air Products® that are designed to reduce compressed air consumption as well as sound levels. For noisy blowoffs where you’re currently using an open-ended pipe or a loud commercial air nozzle, EXAIR’s Super Air Nozzles are the ideal solution. Not only can they pay for themselves over a short period of time time due to compressed air savings, but your operators will thank you when they’re able to hear later on in life!

 EXAIR has the tools you need to reduce sound level in your processes. If you’d like to talk to an Application Engineer about any applications that you feel could benefit from a sound reduction, give us a call.

Jordan Shouse
Application Engineer

Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_JS

Measuring And Adding Sound Levels Together

What sound level do you get when you feed an EXAIR Super Air Nozzle at 80psig? What if there are two of them?  Or three?  Grab your scientific calculators, folks…we’re gonna ‘math’ today!

But first, a little explanation of sound power & sound pressure:

Strictly speaking, power is defined as energy per unit time, and is used to measure energy generation or consumption.  In acoustics, though, sound power is applicable to the generation of the sound…how much sound is being MADE by a noisy operation.

Sound pressure is the way acoustics professionals quantify the intensity of the sound power at the target.  For the purposes of most noise reduction discussions, the target is “your ears.”

The sound levels that we publish are measured at a distance of 3 feet from the product, to the side.  The units we use are decibels, corrected for “A” weighting (which accounts for how the human ear perceives the intensity of the sound, which varies for different frequencies,) or dBA.  Also, decibels follow a logarithmic scale, which means two important things:

  • A few decibels’ worth of change result in a “twice as loud” perception to your ears.
  • Adding sources of sound doesn’t double the decibel level.

If you want to know how the sound level from a single source is calculated, those calculations are found here.  For the purposes of this blog, though, we’re going to assume a user wants to know what the resultant sound level is going to be if they add a sound generating device to their current (known) situation.

Combined Sound Level (dBA) = 10 x log10[10SL1/10 + 10SL2/10 + 10SL3/10 …]

Let’s use an EXAIR Model 1100 Super Air Nozzle (rated at 74dBA) as an example, and let’s say we have one in operation, and want to add another.  What will be the increase in dBA?

10 x log10[1074/10 + 1074/10] = 77.65 dBA

Now, there are two reasons I picked the Model 1100 as an example:

  • It’s one of our most versatile products, with a wide range of applications, and a proven track record of efficiency, safety, and sound level reduction.
  • We proved out the math in a real live experiment:

Why do I care about all of this?  My Dad experienced dramatic hearing loss from industrial exposure at a relatively young age…he got his first hearing aids in his early 40’s…so I saw, literally up close and very personal, what a quality of life issue that can be.  The fact that I get to use my technical aptitude to help others lower industrial noise exposure is more than just making a living.  It’s something I’m passionate about.  If you want to talk about sound level reduction in regard to your use of compressed air, talk to me.  Please.

Russ Bowman
Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook

EXAIR and the Hierarchy of Controls

The CDC (Center for Disease Control) published a useful guide called “Hierarchy of Controls” that details (5) different types of control methods for exposure to occupational hazards while showing the relative effectiveness of each method.

NIOSH_Hierarchy_of_Controls
Hierarchy of Controls

 

The least effective methods are Administrative Controls and Personal Protective Equipment (PPE). Administrative Controls involve making changes to the way people perform the work and promoting safe practices through training. The training could be related to correct operating procedures, keeping the workplace clean, emergency response to incidents, and personal hygiene practices, such as proper hand washing after handling hazardous materials. PPE is the least effective method because the equipment (ear plugs, gloves, respirators, etc.) can become damaged, may be uncomfortable and not used, or used incorrectly.

In the middle range of effectiveness is Engineering Controls. These controls are implemented by design changes to the equipment or process to reduce or eliminate the hazard. Good engineering controls can be very effective in protecting people regardless of the the actions and behaviors of the workers. While higher in initial cost than Administrative controls or PPE, typically operating costs are lower, and a cost saving may be realized in the long run.

The final two, Elimination and Substitution are the most effective but can be the most difficult to integrate into an existing process. If the process is still in the design phase, it may be easier and less expensive to eliminate or substitute the hazard. Elimination of the hazard would be the ultimate and most effective method, either by removing the hazard altogether, or changing the work process so the hazard is no longer part of the process.

EXAIR can help your company follow the Hierarchy of Controls, and eliminate, or substitute the hazards of compressed air use with relative ease. 

Home of Intelligent Compressed Air Products

Engineers can eliminate loud and unsafe pressure nozzles with designs that utilize quiet and intelligent compressed air products such as Air Nozzles, Air Knives and Air Amplifiers. Also, unsafe existing products such as air guns, can be substituted with EXAIR engineered solutions that meet the OSHA standards 29 CFR 1910.242(b) and 29 CFR 1910.95(a).

In summary, Elimination and Substitution are the most effective methods and should be used whenever possible to reduce or eliminate the hazard and keep people safe in the workplace. EXAIR products can be easily substituted for existing, unsafe compressed air products in many cases. And to avoid the hazard altogether, remember EXAIR when designing products  or processes which require compressed air use for cooling, cleaning, ejection, and more. 

If you have questions about the Hierarchy of Controls and safe compressed air usage from any of the 15 different EXAIR Intelligent Compressed Air® Product lines, feel free to contact EXAIR and myself or any of our Application Engineers can help you determine the best solution.

Jordan Shouse
Application Engineer

Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_JS

 

Hierarchy of Controls Image:  used from  Public Domain

EXAIR Digital Sound Level Meters Measure Noise Exposure Levels

slm-newlabel
Digital Sound Meter

EXAIR offers the model 9104 Digital Sound Level Meter.  It is an easy to use instrument for measuring and monitoring the sound level pressures in and around equipment and other manufacturing processes.

Sound meters convert the movement of a thin membrane due to the pressure waves of sound into an electric signal that is processed and turned into a readable output, typically in dBA.  The dBA scale is the weighted scale that most closely matches the human ear in terms of the sounds and frequencies that can be detected.

Noise induced hearing loss can be a significant problem for many workers in manufacturing and mining. To protect workers in the workplace from suffering hearing loss OSHA has set limits to the time of exposure based on the sound level.  The information in the OSHA Standard 29 CFR – 1910.95(a) is summarized below.

OSHA Noise Level

The EXAIR Digital Sound Level Meter is an accurate and responsive instrument that measures the decibel level of the sound and displays the result on the large optionally back-lit LCD display. There is an “F/S” option to provide measurement in either ‘slow’ or ‘fast’ modes for stable or quickly varying noises. The ‘Max Hold’ function will capture and hold the maximum sound level, and update if a louder sound occurs.

Certification of accuracy and calibration traceable to NIST (National Institute of Standards and Technology) is included.

If you have questions about the Digital Sound Level Meter, or would like to talk about any of the quiet EXAIR Intelligent Compressed Air® Products, feel free to contact EXAIR and myself or one of our Application Engineers can help you determine the best solution.

Jordan Shouse
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_JS