How It’s Made: Static Charge

For me, one of the first signs that winter is here takes place at the grocery store. I’ll stop on the way home to pick up a thing or two, and proceed to the automated self-scan…not because I don’t like people, but because they’re the closest to the exit and, while I DO actually like a LOT of people, I REALLY like dinner. Anyway, the drop in humidity that comes with colder temperatures outside leads to what the buried-wire pet containment folks call a “mild correction” when I touch the self-scan terminal.

I won’t rehash my disdain of cold weather (like I did here, herehere, or here) and while those nuisance static shocks aren’t at the top of the list of reasons why, they actually can be quite severe in other cases.  For example, the minor jolt you get from touching a grounded terminal after pushing a rubber-wheeled shopping cart over the vinyl-tiled floor of the produce aisle isn’t near as bad as the shock that a plastic extrusion machine operator gets when he touches a conveyor duct carrying hundreds of pounds of plastic pellets per hour.

Why one is so much worse than the other?  To fully understand the answer to that question, we’ll need to better understand how static charge is generated.  Scientists have been studying the phenomenon since at least the 17th Century, and studies continue to this day of its creation (mainly at universities) and control (right here at EXAIR Corporation.)  Simply put, when two solid surfaces touch each other, the contact can result in electrons in the outer valences of atoms on one surface to “jump ship” and end up in the outer valences of atoms on the other surface.

It’s called the triboelectric effect.  The prefix “tribo” comes from the Greek word “to rub,” and while many common demonstrations of static charge involve rubbing…for example, rubbing a balloon on a wool sweater sleeve and ‘sticking’ it to the wall…mere contact is all it takes – and that’s where we’ll start:

Static charge from simple contact between this injection molded plastic part & the mold caused defects in a subsequent metallic coating process (left,) which were eliminated after an EXAIR Super Ion Air Knife was installed (right.)

Separation of material – lifting the top sheet from a stack, peeling off a protective layer,  or unrolling plastic film, for example – can also cause those weaker-held electrons to leave one surface for another.

Separation of contacting surfaces can generate a considerable static charge. The 16.9kV charge on this roll of film (left) shortened the life of print heads in a downstream process until EXAIR Ionizing Bars (center) dissipated the charge to an inconsequential 0.4kV (right.)

Some processes involve surface contact, and separation.  And more contact, and separation.  And oftentimes, one surface is in relative motion with the other…and that’s what REALLY puts the “tribo” (“to rub,” remember?) in “triboelectric effect.

The constant motion of these plastic jugs on the conveyor (left,) generated (and multiplied) a static charge so great, it resulted in adhesive labels folding or wrinkling while being applied. A pair of EXAIR Super Ion Air Knives (right) solved the problem.

These are just a few examples of the mechanisms behind, and the solutions for, static charge.  For more details, I encourage you to read EXAIR’s Basics Of Static whitepaper (registration required) or watch our recorded Webinar: Understanding Static Electricity.  If you have a static problem you’d like help with, give me a call.

Russ Bowman
Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook

General Good Ideas For The Compressor Room

When considering your compressor room all too often the phrase applies “out of sight and out of mind”.  Of course, we all know that is not a good approach to the compressor room or really anything in life.  Unfortunately, many of us take for granted that very system that delivers the power to keep our machines, equipment and tools operating.

Air Compressor
Compressor Room Located Outdoors

So, what can we do keep the ‘lungs” of our plants performing reliably and efficiently?  Since this Blog is about “General Good Ideas For The Compressor Room”, I have some points below for your consideration.

  • Ideally the compressor room should be centrally located to minimize the length of the pipes and allows for easier noise control. With long piping runs leaks become more likely and frictional losses are increased.
  • The compressor room should be sized to allow for easy maintenance and future expansion.
  • For efficient operation air compressors need clean intake air. Intake air that is dusty, dirty or contains gaseous contamination will reduce the efficiency and possibly the longevity of your equipment.
  • The compressor room needs adequate ventilation since air compressors generate significant heat. If excessive heat is allowed to build up it reduces the efficiency of the air compressor raising utility costs, causes compressor lubricant to break down prematurely that could possibly result in increased maintenance and compressor failure.
  • What is the velocity of the air through the main headers? If the speed is above 1200 FPM many dryers have reduced efficiency and speeds greater than this can also carry moisture past the drainage drop legs.
  • Excess friction caused by too small of a diameter piping creates pressure loss, which reduces efficiency and if the compressor is ran above its pressure rating to overcome the frictional losses increases energy consumption, maintenance costs and down time.

Now that your compressor room is shipshape in Bristol fashion, you might think that all is well.  While that may be true, chances are there are other significant additional savings to be had.  EXAIR specializes in point of use compressed air products that are highly efficient and quiet!  If you have any blow-offs that are open tube or howl as loud as the ghost of Christmas yet to come, check out EXAIR’s Super Air Nozzles.  They are highly efficient and quiet, in fact they meet OSHA Standard 29 CFR – 1941.95 for maximum allowable noise and OSHA Standard 29 CFR 1910.242 (b) for higher than 30 PSIG blow-off pressure.  All of EXAIR’s compressed air products are engineered to minimize compressed air consumption and take advantage of the Coanda effect.  Simply stated EXAIR’s highly engineered, intelligent designs entrain (combine) ambient air with the compressed air supply which saves you money!

nozzle_anim_twit800x320
EXAIR Super Air Nozzle entrainment

EXAIR also offers the Ultra Sonic Leak Detector.  Simply point the device at a suspected leak which are typically found at unions, pipes, valves and fittings from up to 20’ away.   Plants that are not maintaining their plumbing can waste up to 30% of their compressors output through undetected leaks.

ultrasonic_2
EXAIR Ultra Sonic Leak Detector

EXAIR has a complete optimization product line that the Ultra Sonic Leak Detector is in that includes the Electronic Flow Control, Digital Flowmeter’s and a Digital Sound Level Meter.  All designed to either increase the safety or efficiency of your compressed air usage.

EXAIR has 15 other product lines all designed to increase your process efficiency and save you money by using you compressed air supply efficiently.  Why not visit the EXAIR website or call and request a free catalog?

When you are looking for expert advice on safe, quiet and efficient point of use compressed air products give us a call.   We would enjoy hearing from you!

Steve Harrison
Application Engineer
Send me an email
Find us on the Web 
Follow me on Twitte
Like us on Facebook

 

Image taken from the Best Practices for Compressed Air Systems Handbook, 2nd Edition

Super Air Amplifier Overview – Vent, Exhaust, Cool, Dry, Clean

Vent, exhaust, cool, dry, clean -with no moving parts!  That tag line from the catalog section pretty much says it all about the EXAIR Air Amplifiers, both the Super Air Amplifier and the Adjustable Air Amplifiers. I want to share some more information about the Super Air Amplifiers.

In general, the air amplifiers employ the Coanda effect – a basic principle of fluid flow – to create air motion in their surrounding.  Through intelligent design, this surrounding fluid flow can be manipulated and exploited, creating an amplification of a small amount of compressed air.

AirAmplifiers
Super Air Amplifier

How do they work? In the figure below – a small amount of compressed air flows into the unit (1) to an annular chamber (2). The air is then throttled through a small ring nozzle (3) at high velocity. This primary air stream adheres to the Coanda profile (4), which directs it towards the outlet. A low pressure area is created at the center (5), inducing a high volume flow of the surrounding air into the primary stream. At the exit, you have the combination of flows, resulting in a high volume, high velocity flow.

salworks
How Air Amplifiers Work
Super Air Amplifier Coanda Profile
Close Up of the Coanda Profile

The amplification ratio – the outlet airflow compared to the compressed air flow is dependent upon the cross sectional area of the inlet, and the 3/4″ Super Air Amplifiers have 12:1 amplification ratios all the way up to the 4″ and 8″ Super Air Amplifiers with 25:1 amplification ratios! That is a lot of ‘free air’ to use for cooling, drying and cleaning.  And a lot of air or smoke that can be drawn at the inlet and vented away from the area. For more on the amplification ratios, see this -blog-

Each Super Air Amplifier has a patented shim (patent#5402938) that precisely sets the compressed air flow, and shim sets are available to install to increase the force and flow as needed.

Super Air Amplifier Shims
Patented Shims for the Super Air Amplifier

The balanced outflow of air minimizes wind shear to produce a very quiet, powerful flow at sound levels up to three (3) times quieter than other air movers.  A 4″ Super Air Amplifier operated at 80 PSIG will have a Sound Level of just 73 dBA.

The video below shows the power of the Super Air Amplifier in inducing a high volume flow of surrounding air (for venting) into the primary air stream (for cooling/drying/cleaning)

Typical applications include venting weld smoke, cooling hot parts, drying wet parts, cleaning machined parts, distributing heat in mold & ovens, dust collection, and exhausting vent fumes.

If you have questions about the Super Air Amplifier or any of the 16 different EXAIR Intelligent Compressed Air® Product lines, feel free to contact EXAIR and myself or any of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

Happy Holidays From EXAIR!

This is one of the best days at EXAIR. The building is full of cookies, candy, and any number of favorite homemade treats that we all like to share with each other. So far this year we have seen the usual cookies but also cupcakes, sausage balls, salsa, meringues, cheese and crackers and more. You’ll put on weight just reading about it all.

To be fair – today is also a half day, so it just goes hand in hand with a good day.

But beyond those things, EXAIR caters in lunch for all of us. It gives us a chance to hang out, rather than work. We enjoy each others company, talk to people we wouldn’t normally talk to on a normal workday and learn more about each other beyond work. It’s how it should be, we all benefit from spending a bit of quality time together and it helps strengthen our common goals related to EXAIR.

We hope all of you enjoy yourselves over the holidays and spend some time with the great people in your organizations too. From all of us at EXAIR, Merry Christmas and Happy Holidays.