Creating an Efficient Compressed Air System

The electrical costs associated with generating compressed air make it the most expensive utility in any industrial facility. In order to help offset these costs, it’s imperative that the system is operating as efficiently as possible. I’d like to take a moment to walk you through some of the ways that you can work towards making your compressed air system more efficient.

The first step you should take is to identify and fix any leaks within the distribution piping. According to the Compressed Air Challenge, up to 30% of all compressed air generated is lost through leaks. This ends up accounting for nearly 10% of your overall energy costs!! To put leaks in perspective, take a look at the graphic below from the Best Practices for Compressed Air Systems handbook.

Compressed air leaks don’t just waste energy, but they can also contribute to other operating losses. If enough air is lost through leaks, this can also cause a drop in system pressure. This can affect the functionality of other compressed air operated equipment and processes. This pressure drop can affect the efficiency of the equipment causing it to cycle on/off more frequently or to not work properly. This can lead to anything from rejected products to increased running time. With an increase in running time, there’s also the need for more frequent maintenance and unscheduled downtime.

You can perform a compressed air audit in your facility using an EXAIR Model 9061 Ultrasonic Leak Detector. If you’d prefer someone come in and do this for you, there are several companies that offer energy audit services where this will be a focal point of the process.

Speaking of maintenance, proper compressor maintenance is also critical to the overall efficiency of the system. Like all industrial equipment, a proper maintenance schedule is required in order to ensure things are operating at peak efficiency. Inadequate compressor maintenance can have a significant impact on energy consumption via lower compressor efficiency. A regular preventative maintenance schedule is required in order to keep things in good shape. The compressor, heat exchanger surfaces, lubricant, lubricant filter, air inlet filter, and dryer all need to be maintained. This can be done yourself or through a reputable compressor dealer. The costs associated with these services are outweighed in the improved reliability and performance of the compressor. A well-maintained system will not cause unexpected shutdowns and will also cost less to operate.

The manner in which you use your compressed air at the point of use should also be evaluated. Inefficient, homemade solutions are thought to be a cheap and quick solution. Unfortunately, the costs to supply these inefficient solutions with compressed air can quickly outweigh the costs of an engineered solution. An engineered compressed air nozzle such as EXAIR’s line of Super Air Nozzles are designed to utilize the coanda effect. Free, ambient air from the environment is entrained into the airflow along with the supplied compressed air. This maximizes the force and flow of the nozzle while keeping compressed air usage to a minimum.

Another method of making your compressed air system more efficient is actually quite simple: regulating the supply pressure. By installing pressure regulators at the point of use for each of your various point of use devices, you can reduce the consumption simply by reducing the pressure. This can’t be done for everything, but I’d be willing to bet that several tasks could be accomplished with the same level of efficiency at a reduced pressure. Most shop air runs at around 80-90 psig, but for general blowoff applications you can often get by operating at a lower pressure. Another simple, but often overlooked, method is to simply shut off the compressed air supply when not in use. If you haven’t yet performed an audit to identify compressed air leaks this is even more of a no-brainer. When operators go to lunch or during breaks, what’s stopping you from just simply turning a valve to shut off the supply of air? It seems simple and minute, but each step goes a long way towards reducing your overall air consumption and ultimately your energy costs.

Tyler Daniel, CCASS


Application Engineer
E-mail: TylerDaniel@exair.com
Twitter: @EXAIR_TD

Image taken from the Best Practices for Compressed Air Systems Handbook, 2nd Edition

EXAIR’s Safety Air Guns are the Ergonomic Answer

In addition to a variety of engineered Air Nozzles, you can customize your EXAIR Safety Air Gun with Chip Shields, Extensions, Stay Set Hoses, etc., to meet the particular needs of a specific application.

EXAIR has a nice selection of Safety Air Guns. The VariBlast Precision and Compact, Soft Grip, Heavy Duty and Super Blast Safety Air Guns are available with a variety of air nozzles, chip shields and pipe extensions. They are durable and comfortable and ergonomic to use.

These Safety Air Guns are designed with durability and comfort in mind while also ergonomically safe to use. Safe operation is assured along with low air consumption and noise levels.

EXAIR Engineered air nozzles are available in Type 316 stainless steel for superior corrosion resistance and mechanical wear, Type 303 stainless steel for corrosion resistance, PEEK thermoplastic for non-marring and chemical resistance or zinc/aluminum alloy for general purpose applications.

Flying Debris? – Chip Shields are durable polycarbonate shields that protect the operator from risk of flying debris often seen when blowing off chips from machined parts. They are also useful to prevent coolant from splashing back, creating a mess during drying processes.

The Chip Shields are available for EXAIR’s VariBlast, Soft Grip and Heavy Duty Safety Air Guns. The Chip Shield can be used on Safety Air Guns with or without an aluminum extension. They may be purchased as part of a new air gun system, or retrofitted as a Chip Shield Kit.  Consult an Application Engineer for selection assistance.

If you have a blow-off process where the air is to be directed at a distance away from the operator, or into a hard to reach location an extension is the solution. Available in lengths from 6″ (152mm) to 72″ (1829mm), with sizes as to meet most requirement can be found. To add an extension to an air gun, simply add -xx to the current part number..

EXAIR’s Stay Set Hoses are available from 6”-36” in lengths with ¼ NPT male threads on each end, or a ¼ NPT male on one end and 1/8 NPT female on the other. The Stay Set Hoses are rigid and allow you to maintain precise positioning of the blow off nozzle. The hoses have “memory” and will not creep or bend.

 If you need a 12′ coiled air hose, to use with your Safety Air Gun, we have them available and in stock. Available with 1/8 NPT, 1/4 NPT or 3/8 NPT male end swivel connections. Avoid tangled and messy air lines and keep things neat!

If you have ab application and need help deciding which EXAIR Safety Air Gun and/Nozzle you need. Please contact us and ask for any Application Engineer. We are always happy and eager to help.

Eric Kuhnash
Application Engineer
E-mail: EricKuhnash@exair.com
Twitter: Twitter: @EXAIR_EK

Compressed Air Efficiency! “Step One”

I’m currently in the closing process of selling my first home. This is the house I got married in, brought my first child home to. Needless to say there has been a lot going on to get the place up to selling shape, one of those things was getting the HVAC system checked out to verify its running correctly and efficiently! (Spoiler, mine was running very well thank goodness)

With compressed air being considered a fourth utility its important we check the efficiency of the system and fix issues and install upgrades where we can! EXAIR has six simple steps to optimize your compressed air system. Following these steps will help you to cut electrical costs, reduce overhead, and improve your bottom line. In this blog, I will cover the first step – Measure the air consumption to find sources that use a lot of compressed air.

EXAIR Six Steps To Optimizing Your Compressed Air System

Data is important to have when diagnosing wasteful and problematic areas within your compressed air system. To measure air consumption, flow meters are used to find the volume or mass of compressed air per unit of time. Flow rates are very useful data points to find problems like leaks, over-use in blow-offs, waste calculations, and comparison analysis.

The first step to optimizing compressed air systems within an industrial facility is to get a known baseline. To do so, utilizing a digital flowmeter is an ideal solution that will easily install onto a hard pipe that will give live readouts of the compressed air usage for the line it is installed on.  There is also an additional feature that we offer on the Digital Flowmeters that can help further the understanding of the compressed air demands within a facility.

The Pressure Sensing Digital Flowmeters are available from 2″ Sched. 40 Iron Pipe up to 8″ Sched. 40 Iron Pipe.  As well as 2″ to 4″ Copper pipe.  These will read out and with the additional Data Logger or Wireless Capability options record the information. When coupled with the wireless capability an alarm can be set for pressure drops that give live updates on the system as well as permits data review to see system trends throughout the day.

Generating a pressure and consumption profile of a system can help to pinpoint energy wasters such as timer-based drains that are dumping every hour versus level based drains that only open when needed. A scenario similar to this was the cause of an entire production line shut down nearly every day of the week for a local facility until they installed flowmeters and were able to narrow the demand location down to a filter bag house with a faulty control for the cleaning cycle.

If you would like to discuss the best digital flowmeter for your system and to better understand the benefits of pressure sensing, please contact us.

Jordan Shouse
Application Engineer

Send me an Email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_JS

Plumb it Right for Full Performance!

Many times when we provide the air consumption of an EXAIR product, we get a response like…. “I’ve got plenty of pressure, we run at around 100 PSIG”. While having the correct pressure available is important, it doesn’t make up for the volume requirement or SCFM (Standard Cubic Feet per Minute) needed to maintain that pressure. We commonly reference trying to supply water to a fire hose with a garden hose, it is the same principle, in regards to compressed air.

When looking to maintain an efficient compressed air system, it’s important that you use properly sized supply lines and fittings to  support the air demand (SCFM) of the point-of-use device. The smaller the ID and the longer the length of air supply line, it becomes more difficult for the air to travel through the system. Undersized supply lines or piping can sometimes be the biggest culprit in a compressed air system as they can lead to severe pressure drops or the loss of pressure from the compressor to the end use product.

Take for example our 18″ Super Air Knife. An 18″ Super Air Knife will consume 52.2 SCFM at 80 PSIG. We recommend using 1/2″ Schedule 40 pipe up to 10′ or 3/4″ pipe up to 50′. The reason you need to increase the pipe size after 10′ of run is that 1/2″ pipe can flow close to 100 SCFM up to 10′ but for a 50′ length it can only flow 42 SCFM. On the other hand, 3/4″ pipe is able to flow 100 SCFM up to 50′ so this will allow you to carry the volume needed to the inlet of the knife, without losing pressure through the line.

Pipe size chart for the Super Air Knife

Another problem area is using restrictive fittings, like quick disconnects. While this may be useful with common everyday pneumatic tools, like an impact wrench or nail gun, they can severely limit the volumetric flow to a device requiring more air , like a longer length air knife.

1/4″ Quick Connect

For example, looking at the above 1/4″ quick disconnect, the ID of the fitting is much smaller than the NPT connection size. In this case, it is measuring close to .192″. If you were using a device like our Super Air Knife that features 1/4″ FNPT inlets, even though you are providing the correct thread size, the small inside diameter of the quick disconnect causes too much of a restriction for the volume (SCFM) required to properly support the knife, resulting in a pressure drop through the line, reducing the overall performance.

If you have any questions about compressed air applications or supply lines, please contact one of our application engineers for assistance.

Jordan Shouse
Application Engineer

Send me an Email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_JS