Business Benefits From Compressed Air Efficiency

Use of compressed air, or “the fourth utility” as it’s called, is widespread in many industries.  How you use it in your business is important, for a couple of key considerations:

Monetary cost

Compressed air isn’t free.  Heck, it isn’t even cheap.  According to a Tip Sheet on the U.S. Department of Energy’s website, some companies estimate the cost of generation at $0.18 – $0.30 per 1,000 cubic feet of air.  A typical industrial air compressor will make 4-5 Standard Cubic Feet per Minute per horsepower.  Let’s be generous and assume that our 100HP compressor puts out 500 SCFM and is fully loaded 85% of the time over two shifts per day, five days a week:

500 SCFM X $0.18/1,000 SCF X 60 min/hr X 16 hr/day X 5 days/week X 52 weeks/year =

$22,464.00 estimated annual compressed air cost

If you want to go jot down some numbers from your compressor’s nameplate and your last electric bill, you can accurately calculate your actual cost.  Here’s the formula:

Taking our same 100HP compressor (105 bhp required,) fully loaded 85% of the time, and assuming the motor’s good (95% efficient):

(105 bhp X 0.746 X 4,160 hours X $0.08/kWh X 0.85 X 1.0)÷ 0.95 =

$23,324.20 actual annual compressed air cost

So, our estimate was within 4% of our actual…but the point is, $22,000 to $23,000 is a significant amount of money, which deserves to be spent as wisely as possible, and that means using your compressed air efficiently.  Engineered solutions like EXAIR Intelligent Compressed Air Products can be a major part of this – look through our Case Studies; implementing our products have saved companies as much as 60% on their compressed air costs.

Health & Safety

Injuries and illnesses can be big expenses for business as well. Inefficient use of compressed air can be downright unsafe.  Open ended blow offs present serious hazards, if dead-ended…the pressurized (energized) flow can break the skin and cause a deadly air embolism.  Even some air nozzles that can’t be dead ended (see examples of cross-drilled nozzles on right) cause a different safety hazard, hearing loss due to noise exposure.  This is another case where EXAIR can help.  Not only are our Intelligent Compressed Air Products fully OSHA compliant in regard to dead end pressure, their efficient design also makes them much quieter than other devices.

Efficient use of compressed air can make a big difference in the workplace – not only to your financial bottom line, but to everyone’s safety, health, and livelihood.  If you’d like to find out more about how EXAIR can help, give me a call.

Russ Bowman
Application Engineer
EXAIR Corporation
Visit us on the Web
Follow me on Twitter
Like us on Facebook

Six Steps to Optimization, Step 4 – Turn Off Your Compressed Air When Not in Use

Step 4 of the Six Steps To Optimizing Your Compressed Air System is ‘Turn off the compressed air when it isn’t in use.’  Click on the link above for a good summary of the all the steps.

6 Steps from Catalog

Two basic methods to set up a compressed air operation for turning off is the ball valve and the solenoid valve. Of the two, the simplest is the ball valve. It is a quarter turn, manually operated valve that stops the flow of the compressed air when the handle is rotated 90°. It is best for operations where the compressed air is needed for a long duration, and shut off is infrequent, such as at the end of the shift.

manual_valves (2)
Manual Ball Valves, from 1/4 NPT to 1-1/4 NPT

The solenoid valve offers more flexibility. A solenoid valve is an electro-mechanical valve that uses electric current to produce a magnetic field which moves a mechanism to control the flow of air. A solenoid can be wired to simple push button station, for turning the air flow on and off – similar to the manual valve in that relies on a person to remember to turn the air off when not needed.

wa_solvalv
A Wide Array of Solenoid Valve Offerings for Various Flows and Voltage Requirements

Another way to use a solenoid valve is to wire it in conjunction with a PLC or machine control system. Through simple programming, the solenoid can be set to turn on/off whenever certain parameters are met. An example would be to energize the solenoid to supply an air knife when a conveyor is running to blow off parts when they pass under. When the conveyor is stopped, the solenoid would close and the air would stop blowing.

The EXAIR EFC (Electronic Flow Control) is a stand alone solenoid control system. The EFC combines a photoelectric sensor with a timer control that turns the air on and off based on the presence (or lack of presence) of an object in front of the sensor. There are 8 programmable on/off modes for different process requirements. The use of the EFC provides the highest level of compressed air usage control. The air is turned on only when an object is present and turned off when the object has passed by.

efcapp
EFC Used To Control Bin Blow Off Operation

By turning off the air when not needed, whether by a manual ball valve, a solenoid valve integrated into the PLC machine control or the EXAIR EFC, compressed air usage will be minimized and operation costs reduced.

If you have questions about the EFC, solenoid valves, ball valves or any of the 15 different EXAIR Intelligent Compressed Air® Product lines, feel free to contact EXAIR and myself or any of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

Cabinet Cooling with Thermostat Control and ETC

An EXAIR Cabinet Cooler® System with either the Thermostat Control or the Electronic Temperature Control (ETC) option includes a temperature measuring device that is used to control the operation of the Cabinet Cooler System to maintain the set-point temperature.Thermostat and ETC

For most industrial enclosure cooling applications, a temperature of 95°F (35°C) is sufficient to be below the rated maximum operating temperature of the electrical components inside the cabinet. EXAIR Thermostats are preset to 95°F (35°C) and are adjustable. Maintaining the cabinet at 95°F (35°C) will keep the electronics cool and provide long life and reduced failures due to excessive heat. But if 95°F (35°C) is good, why not cool the cabinet to 70°F (21.1°C)?

When cooling an enclosure to a lower temperature, two things come into play that need to be considered. First, the amount of external heat load (the heat load caused by the environment) is increased. Using the table below, we can see the effect of cooling a cabinet to the lower temperature. For a 48″ x 36″ x 18″ cabinet, the surface area is 45 ft² (4.18 m²). If the ambient temperature is 105°F (40.55°C), we can find from the table the factors of 3.3 BTU/hr/ft² and 13.8 BTU/hr/ft² for the Temperature Differentials of 10°F (5.55°C) and 35°F (19.45°C). The factor is multiplied by the cabinet surface area to get the external heat load. The heat load values calculate to be 148.5 BTU/hr and 621 BTU/hr, a difference of 472.5 BTU/hr (119.1 kcal/hr)

External Heat Load

The extra external heat load of 472.5 BTU/hr (119.1 kcal/hr) will require the Cabinet Cooler System to run more often and for a longer duration to effectively remove the additional heat. This will increase, unnecessarily, the operating costs of the cooling operation.

The other factor that must be considered when cooling an enclosure to a lower temperature is that the Cabinet Cooler cooling capacity rating is effected. I won’t go into the detail in this blog, but note that a 1,000 BTU/hr Cabinet Cooler (rated for 95°F (35°C cooling) working to cool a cabinet down to 70°F (21.1°C) instead of 95°, has a reduced cooling capacity of 695 BTU/hr (174 kcal/hr).  The reduction is due to the cold air being able to absorb less heat as the air rises in temperature to 70°F instead of 95°F.

In summary – operating a Cabinet Cooler System at 95°F (35°C) provides a level cooling that will keep sensitive electronics cool and trouble-free, while using the least amount of compressed air possible.  Cooling to below this level will result in higher operation costs.

If you have questions about Cabinet Cooler Systems or any of the 15 different EXAIR Intelligent Compressed Air® Product lines, feel free to contact EXAIR and myself or any of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

Compressed Air Use in the Aerospace Industry

EXAIR’s products have been used for a very large selection of applications in almost every industry.  Today I want to highlight a few that pertain to the Aerospace Industry.

First – a quick lesson on how to access the Applications database– Be sure to Register and then Log In

From the main page, hover the mouse pointer over ‘KNOWLEDGE BASE‘ and the pop-up menu will appear as seen below.  Select ‘APPLICATIONS’ Website Applications.png

On the left hand side of the screen you will see a gray navigation pane that shows Application with a list underneath.  Scroll down the main page and you will see a second heading in the navigation pane labeled “Industry”.  You can select your industry from the list provided.  For today’s example we will select Aerospace.

Industry_App_Database
The Industry section of the Application Database is found on the left hand side of the screen in the navigation pane.

Once the industry is selected there will be a new list of applications that are displayed in the center of the page.   Simply select the application you would like more information on and the details will display.

Below, we showcase the application from a machine manufacturer for the Aerospace industry.   This customer manufactured the production equipment of a flexible, porous material that is continuously passed through a wash tank prior to cutting to length.  They were interested in speeding the drying process of this strand, and considered blowing hot air onto it.  It was not feasible to install an electrically powered hot air blower or gun.  They needed an air flow of approximately 15 SCFM at 200°F, and had 70 psig air supply with a large volume available.  They utilized a Vortex Tube installed over the strand after it exited the dip tank.   The Vortex Tube was oriented with the hot air exhaust blowing on to the strand to dry the strand.  The customer stated that they not only met their expectations but exceeded the original hopes and were able to dry the product quicker and safer than expected.

Vortex_Tube_Drying_Material
Selecting any of the listed applications in the center of the screen will display the details of that particular application.

This is just one of many applications that are showcased in the Application Database for the Aerospace industry.   Those are just a small sampling of the thousands of applications that can be researched through the database.  If you would like to share your application to the database, feel free to contact an Application Engineer.

If you have questions about any of the 15 different EXAIR Intelligent Compressed Air® Product lines, feel free to contact EXAIR and myself or any of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB