Laminar Flow and Digital Flowmeters: An Explanation On How To Achieve Laminar Flow

When I see turbulent flow vs. laminar flow I vaguely remember my fluid dynamics class at the University of Cincinnati.  A lot of times when one thinks about the flow of a liquid or compressed gas within a pipe they want to believe that it is always going to be laminar flow. This, however, is not true and there is quite a bit of science that goes into this.  Rather than me start with Reynolds number and go through flow within pipes I have found this amazing video from a Mechanical Engineering Professor in California. Luckily for us, they bookmarked some of the major sections. Watch from around the 12:00 mark until around the 20:00 mark. This is the good stuff.

The difference between entrance flow, turbulent flow and laminar flow is shown ideally at around the 20:00 mark.  This length of piping that is required in order to achieve laminar flow is one of the main reasons our Digital Flowmeters are required to be installed within a rigid straight section of pipe that has no fittings or bends for 30 diameters in length of the pipe upstream with 5 diameters of pipe in length downstream.

This is so the meter is able to measure the flow of compressed air at the most accurate location due to the fully developed laminar flow. As long as the pipe is straight and does not change diameter, temperature, or have fittings within it then the mass, velocity, Q value all stay the same.  The only variable that will change is the pressure over the length of the pipe when it is given a considerable length.

Another great visualization of laminar vs. turbulent flow, check out this great video.

 

If you would like to discuss the laminar and turbulent flow please contact an Application Engineer.

Brian Farno
Application Engineer
BrianFarno@EXAIR.com
@EXAIR_BF

1 -Fluid Mechanics: Viscous Flow in Pipes, Laminar Pipe Flow Characteristics (16 of 34) – CPPMechEngTutorials – https://www.youtube.com/watch?v=rQcZIcEa960

2 – Why Laminar Flow is AWESOME – Smarter Every Day 208 – SmarterEveryDay – https://www.youtube.com/watch?v=y7Hyc3MRKno

 

 

Applying a Vortex Tube and Adjusting Temperature

Throughout my tenure with EXAIR there are may days where I have tested different operating pressure, volumetric flow rates, back pressures, lengths of discharge tubing, generator compression, and even some new inquiries with cold air distribution all on a vortex tube.  These all spawn from great conversations with existing customers or potential customers on different ways to apply and applications for vortex tubes.

Many of the conversations start in the same spot… How exactly does this vortex tube work, and how do I get the most out of it?  Well, the answer is never the same as every application has some variation.  I like to start with a good idea of the area, temperatures, and features of exactly what we are trying to cool down.  The next step is learning how fast this needs to be done.  That all helps determine whether we are going to be looking at a small, medium, or large vortex tube and which cooling capacity to choose.   After determining these factors the explanation on how to adjust the vortex tube to meet the needs of the application begins.

This video below is a great example of how a vortex tube is adjusted and what the effects of the cold fraction have and just how easy it is to adjust.  This adjustment combined with varying the air pressure gives great versatility within a single vortex tube.

The table below showcases the test points that we have cataloged for performance values.  As the video illustrates, by adjusting the cold fraction lower, meaning less volumetric flow of air is coming out of the cold side and more is exhausting out the hot side, the colder the temperature gets.

EXAIR Vortex Tube Performance Chart

This chart helps to determine the best case scenario of performance for the vortex tube.  Then the discussion leads to delivery of the cold or hot air onto the target.  That is where the material covered in these two blogs, Blog 1, Blog 2 comes into play and we get to start using some math.  (Yes I realize the blogs are from 2016, the good news is the math hasn’t changed and Thermodynamics hasn’t either.)  This then leads to a final decision on which model of vortex tube will best suit the application or maybe if a different products such as a Super Air Amplifier (See Tyler Daniel’s Air Amplifier Cooling Video here.)is all that is needed.

Where this all boils down to is, if you have any questions on how to apply a vortex tube or other spot cooling product, please contact us.  When we get to discuss applications that get extremely detailed it makes us appreciate all the testing and experience we have gained over the years.  Also, it helps to build on those experiences because no two applications are exactly the same.

Brian Farno
Application Engineer
BrianFarno@EXAIR.com
@EXAIR_BF

 

Minimize Exposure to Hazards Using the Hierarchy of Controls

The CDC (Center for Disease Control) published a useful guide called “Hierarchy of Controls” that details (5) different types of control methods for exposure to occupational hazards while showing the relative effectiveness of each method.

HierarchyControls
CDC Hierarchy of Controls

The least effective methods are Administrative Controls and PPE. Administrative Controls involve making changes to the way people perform the work and promoting safe practices through training. The training could be related to correct operating procedures, keeping the workplace clean, emergency response to incidents, and personal hygiene practices, such as proper hand washing after handling hazardous materials. PPE (Personal Protective Equipment) is the least effective method because the equipment (ear plugs, gloves, respirators, etc.) can become damaged, may be uncomfortable and not used, or used incorrectly.

In the middle range of effectiveness is Engineering Controls. These controls are implemented by design changes to the equipment or process to reduce or eliminate the hazard. Good engineering controls can be very effective in protecting people regardless of the the actions and behaviors of the workers. While higher in initial cost than Administrative controls or PPE, typically operating costs are lower, and a cost saving may be realized in the long run.

The final two, Elimination and Substitution are the most effective but can be the most difficult to integrate into an existing process. If the process is still in the design phase, it may be easier and less expensive to eliminate or substitute the hazard. Elimination of the hazard would be the ultimate and most effective method, either by removing the hazard altogether, or changing the work process to the hazardous task is no longer performed.

EXAIR can help your company follow the Hierarchy of Controls, and eliminate, or reduce the hazards of compressed air usage.

Engineers can eliminate loud and unsafe pressure nozzles with designs that utilize quiet and pressure safe engineered air products such as Air Nozzles, Air Knives and Air Amplifiers. Also, unsafe existing products such as air guns, can be substituted with EXAIR engineered solutions that meet the OSHA standards 29 CFR 1910.242(b) and 29 CFR 1910.95(a).

Nozzles

In summary, Elimination and Substitution are the most effective methods and should be used whenever possible to reduce or eliminate the hazard and keep people safe in the workplace.

If you have questions about the Hierarchy of Controls and safe compressed air usage from any of the 15 different EXAIR Intelligent Compressed Air® Product lines, feel free to contact EXAIR and myself or any of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

How to Calculate SCFM (Volume) When Operating at Any Pressure

If you need to operate at a different pressure because you require less or more force or simply operate at a different line pressure, this formula will allow you to determine the volume of air being consumed by any device.

Volume Formula

Using the EXAIR 1100 Super Air Nozzle as our example:

1100

Lets first consider the volume of the 1100 Super Air Nozzle at a higher than published pressure.  As shown in the formula and calculations it is simply the ratio of gauge pressure + atmospheric divided by the published pressure + atmospheric and then multiply the dividend by the published volume.  So as we do the math we solve for 17.69 SCFM @ 105 PSIG from a device that was  shown consume 14 SCFM @ 80 PSIG.

higher

Now lets consider the volume at a lower than published pressure.  As shown it is simply the ratio of gauge pressure + atmospheric divided by the published pressure + atmospheric and then multiply the dividend by the published volume.  So as we do the math we solve for 11.04 SCFM @ 60 PSIG from a device that was shown to consume 14 SCFM @ 80 PSIG.

lower