Six Steps to Optimization, Step 4 – Turn Off Your Compressed Air When Not in Use

Step 4 of the Six Steps To Optimizing Your Compressed Air System is ‘Turn off the compressed air when it isn’t in use.’  Click on the link above for a good summary of the all the steps.

6 Steps from Catalog

Two basic methods to set up a compressed air operation for turning off is the ball valve and the solenoid valve. Of the two, the simplest is the ball valve. It is a quarter turn, manually operated valve that stops the flow of the compressed air when the handle is rotated 90°. It is best for operations where the compressed air is needed for a long duration, and shut off is infrequent, such as at the end of the shift.

manual_valves (2)
Manual Ball Valves, from 1/4 NPT to 1-1/4 NPT

The solenoid valve offers more flexibility. A solenoid valve is an electro-mechanical valve that uses electric current to produce a magnetic field which moves a mechanism to control the flow of air. A solenoid can be wired to simple push button station, for turning the air flow on and off – similar to the manual valve in that relies on a person to remember to turn the air off when not needed.

wa_solvalv
A Wide Array of Solenoid Valve Offerings for Various Flows and Voltage Requirements

Another way to use a solenoid valve is to wire it in conjunction with a PLC or machine control system. Through simple programming, the solenoid can be set to turn on/off whenever certain parameters are met. An example would be to energize the solenoid to supply an air knife when a conveyor is running to blow off parts when they pass under. When the conveyor is stopped, the solenoid would close and the air would stop blowing.

The EXAIR EFC (Electronic Flow Control) is a stand alone solenoid control system. The EFC combines a photoelectric sensor with a timer control that turns the air on and off based on the presence (or lack of presence) of an object in front of the sensor. There are 8 programmable on/off modes for different process requirements. The use of the EFC provides the highest level of compressed air usage control. The air is turned on only when an object is present and turned off when the object has passed by.

efcapp
EFC Used To Control Bin Blow Off Operation

By turning off the air when not needed, whether by a manual ball valve, a solenoid valve integrated into the PLC machine control or the EXAIR EFC, compressed air usage will be minimized and operation costs reduced.

If you have questions about the EFC, solenoid valves, ball valves or any of the 15 different EXAIR Intelligent Compressed Air® Product lines, feel free to contact EXAIR and myself or any of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

Cabinet Cooling with Thermostat Control and ETC

An EXAIR Cabinet Cooler® System with either the Thermostat Control or the Electronic Temperature Control (ETC) option includes a temperature measuring device that is used to control the operation of the Cabinet Cooler System to maintain the set-point temperature.Thermostat and ETC

For most industrial enclosure cooling applications, a temperature of 95°F (35°C) is sufficient to be below the rated maximum operating temperature of the electrical components inside the cabinet. EXAIR Thermostats are preset to 95°F (35°C) and are adjustable. Maintaining the cabinet at 95°F (35°C) will keep the electronics cool and provide long life and reduced failures due to excessive heat. But if 95°F (35°C) is good, why not cool the cabinet to 70°F (21.1°C)?

When cooling an enclosure to a lower temperature, two things come into play that need to be considered. First, the amount of external heat load (the heat load caused by the environment) is increased. Using the table below, we can see the effect of cooling a cabinet to the lower temperature. For a 48″ x 36″ x 18″ cabinet, the surface area is 45 ft² (4.18 m²). If the ambient temperature is 105°F (40.55°C), we can find from the table the factors of 3.3 BTU/hr/ft² and 13.8 BTU/hr/ft² for the Temperature Differentials of 10°F (5.55°C) and 35°F (19.45°C). The factor is multiplied by the cabinet surface area to get the external heat load. The heat load values calculate to be 148.5 BTU/hr and 621 BTU/hr, a difference of 472.5 BTU/hr (119.1 kcal/hr)

External Heat Load

The extra external heat load of 472.5 BTU/hr (119.1 kcal/hr) will require the Cabinet Cooler System to run more often and for a longer duration to effectively remove the additional heat. This will increase, unnecessarily, the operating costs of the cooling operation.

The other factor that must be considered when cooling an enclosure to a lower temperature is that the Cabinet Cooler cooling capacity rating is effected. I won’t go into the detail in this blog, but note that a 1,000 BTU/hr Cabinet Cooler (rated for 95°F (35°C cooling) working to cool a cabinet down to 70°F (21.1°C) instead of 95°, has a reduced cooling capacity of 695 BTU/hr (174 kcal/hr).  The reduction is due to the cold air being able to absorb less heat as the air rises in temperature to 70°F instead of 95°F.

In summary – operating a Cabinet Cooler System at 95°F (35°C) provides a level cooling that will keep sensitive electronics cool and trouble-free, while using the least amount of compressed air possible.  Cooling to below this level will result in higher operation costs.

If you have questions about Cabinet Cooler Systems or any of the 15 different EXAIR Intelligent Compressed Air® Product lines, feel free to contact EXAIR and myself or any of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer
Send me an email
Find us on the Web 
Like us on Facebook
Twitter: @EXAIR_BB

Air: What is it?

Air Balloons

What is Air? Air is an invisible gas that supports life on earth. Dry air is made from a mixture of 78% Nitrogen, 21% Oxygen, and 1% of remaining gases like carbon dioxide and other inert gases.  Ambient air contains an average of 1% water vapor, and it has a density of 0.0749 Lbs./cubic foot (1.22 Kg/cubic meter) at standard conditions.  Air that surrounds us does not have a smell, color, or taste, but it is considered a fluid as it follows the rules of fluid dynamics. But unlike liquids, gases like air are compressible.  Once we discovered the potential of compressing the surrounding air, we were able to advance many technologies.

Bellows

Guess when the earliest air compressor was used?  Believe it or not, it was when we started to breathe air.  Our diaphragms are like compressors.  It pulls and pushes the air in and out of our lungs.  We can generate up to 1.2 PSI (80 mbar) of air pressure.  During the iron age, hotter fires were required for smelting.  Around 1500 B.C., a new type of air compressor was created, called a bellows.  You probably seen them hanging by the fireplaces.  It is a hand-held device with a flexible bag that you squeeze together to compress the air.  The high stream of air was able to get higher temperature fires to melt metals.

Then we started to move into the industrial era.  Air compressors were used in mining industries to move air into deep caverns and shafts.  Then as the manufacturing technologies advanced, the requirements for higher air pressures were needed.  The stored energy created by compressing the air allowed us to develop better pneumatic systems for manufacturing, automation, and construction.  I do not know what the future holds in compressed air systems, but I am excited to find out.

Since air is a gas, it will follow the basic rules of the ideal gas law;

PV = nRT  (Equation 1)

P – Pressure

V – Volume

n – Amount of gas in moles

R – Universal Gas Constant

T – Temperature

If we express the equation in an isothermal process (same temperature), we can see how the volume and pressure are related.  The equation for two different states of a gas can be written as follows:

P1 * V1 = P2 * V2  (Equation 2)

P1 – Pressure at initial state 1

V1 – Volume at initial state 1

P2 – Pressure at changed state 2

V2 – Volume at changed state 2

If we solve for P2, we have:

P2 = (P1 * V1)/V2  (Equation 3)

In looking at Equation 3, if the volume, V2, gets smaller, the pressure, P2, gets higher.  This is the idea behind how air compressors work.  They decrease the volume inside a chamber to increase the pressure of the air.  Most industrial compressors will compress the air to about 125 PSI (8.5 bar).  A PSI is a pound of force over a square inch.  For metric pressure, a bar is a kg of force over a square centimeter.  So, at 125 PSI, there will be 125 pounds of force over a 1” X 1” square.  This amount of potential energy is very useful to do work for pneumatic equipment.  To simplify the system, the air gets compressed, stored as energy, released as work and is ready to be used again in the cycle.

Air Compressor

Compressed air is a clean utility that is used in many different applications.  It is much safer than electrical or hydraulic systems.  Since air is all around us, it is an abundant commodity for air compressors to use.  But because of the compressibility factor of air, much energy is required to create enough pressure in a typical system.  It takes roughly 1 horsepower (746 watts) of power to compress 4 cubic feet of air (113L) to 125 PSI (8.5 bar) every minute.  With almost every manufacturing plant in the world utilizing compressed air in one form or another, the amount of energy used to compress air is extraordinary.  So, utilizing compressed air as efficiently as possible is mandatory.  Air is free, but making compressed air is expensive

If you have questions about getting the most from your compressed air system, or would like to talk about any EXAIR Intelligent Compressed Air® Products, you can contact an Application Engineer at EXAIR.

John Ball
Application Engineer
Email: johnball@exair.com
Twitter: @EXAIR_jb

 

Picture: Hot Air Rises by Paul VanDerWerf. Creative Commons Attribution 2.0 Generic.

Picture: Bellows by Joanna Bourne. Creative Commons Attribution 2.0 Generic.

Picture: Air Compressor by Chris Bartle. Creative Commons Attribution 2.0 Generic.

ROI – Return on Investment

Return on Investment (ROI) is a measure of the gain (preferably) or loss generated relative to the amount of money that was invested.  ROI is typically expressed as a percentage and is generally used for personal financial decisions, examining the profitability of a company, or comparing different investments.  It can also be used to evaluate a project or process improvement to decide whether spending money on a project makes sense.  The formula is shown below-

ROI

  • A negative ROI says the project would result in an overall loss of money
  • An ROI at zero is neither a loss or gain scenario
  • A positive ROI is a beneficial result, and the larger the value the greater the gain

Gain from investment could include many factors, such as energy savings, reduced scrap savings, cost per part due to increased throughput savings, and many more.  It is important to analyze the full impact and to truly understand all of the savings that can be realized.

Cost of investment also could have many factors, including the capital cost, installation costs, downtime cost for installation, and others.  The same care should be taken to fully capture the cost of the investment.

Example – installing a Super Air Nozzles (14 SCFM compressed air consumption) in place of 1/4″ open pipe (33 SCFM of air consumption consumption) .  Using the Cost Savings Calculator on the EXAIR website, model 1100 nozzle will save $1,710 in energy costs. The model 1100 nozzle costs $37, assuming a $5 compression fitting and $50 in labor to install, the result is a Cost of Investment of $92.00. The ROI calculation for Year 1 is-

ROI2

ROI = 1,759% – a very large and positive value.  Payback time is only 13 working days.

Armed with the knowledge of a high ROI, it should be easier to get projects approved and funded.  Not proceeding with the project costs more than implementing it.

If you have questions regarding ROI and need help in determining the gain and cost from invest values for a project that includes an EXAIR Intelligent Compressed Air® Product, feel free to contact EXAIR and myself or one of our Application Engineers can help you determine the best solution.

Brian Bergmann
Application Engineer

Send me an email